Application:

1. This is belong to DZ47L C45L RCBO is used for the protection against electrical leakage in the circuit of 50Hz or 60Hz, rated voltage 1 phase 230V and 3 phase 400V, rated current up to 63A.

2. When somebody gets an electric shock or the residual current of the circuit exceeds the fixed value, the ELCB can cut off the power within the time.

3. It is automatically to protect the personal safety and preventing the equipment from the fault resulted by the residual current.

4. With this function, the ELCB can protect the circuit against overload and short circuit or can be used for the unfrequent switchover of the circuit under normal conditions.

5. It conforms to IEC61009 standard.

Normal Operation and Mounting Requirement:

◆Circumstance temperature -5~+40, average temperature not exceeding 35.
◆Altitude above sea level less than 2000m.
◆Humidity not exceeding 50% at 40 and not exceeding 90% at 25.
◆Installation class II or III.
◆Pollution class II.
◆Installation method DIN Rail mounting type.
◆The external magnetism shall not be more than 5 times of terrestrial one.
◆Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position.

Performance & Usage

Circuit breaker is mainly suitable for overload and short protection. It is especially used for illumination and distribution. It is of pleasing out-look, light weight, reliable performance, high breaking capacity, quick trip. etc.

Standard

lEC/EN61009-1

Poles

1P+N,2P,3P,3P+N,4P

Type(wave form of the earth leakage sensed)

AC

Thermo-magnetic release characteristic

C,D

Rated sensitivity lΔn

0.03A,0.05A,0.1A,0.3A

Rated residual making and breaking capacity lΔm

500(ln<63A)630(ln=63A)

Rated short-circuit capacity lcn

3000/4500A

Break time under lΔn

≤0.1s

Rated impulse withstand voltage(1.2/50)Uimp

4000V

Dielectric test voltage at ind.Freq.for 1min

2KV

lnsulation voltage Ui

500V

Electrical life

2000t

Mechanical life

2000t

Contact position indicator

Yes

Protection degree

lP20

Ambient temperature(with daily average≤35°c)

-5~+40°c

Storage temperature

-25~+70°c

Terminal connection type

Cable/Pin-type busbar

Terminal size top/bottom for cable

25mm²

18-3AWG

Terminal size top/bottom for busbar

25mm²

18-3AWG

Tightening torque

2N*m

18ln-lbsm

Mounting

On DIN rail EN  60715(35mm)by means of fast clip device

 

Product Purpose:

1.Personnal and fire protection cable and line protection against overload and short-circuits

2,General rules for choosing RCBO:

A. Rated residual operating current

lΔn≤30mA:additional protection in the case of direct contact

lΔn≤300mA:preventative fire protection in the case of ground fault currents

B. Tripping class

Operation Principle:

MBR416C Operation Principle

Meba Earth Leakage Circuit Breakers MBR416C frame and parts adopt plastic of high inflammable resistance and shock resistance for long service life. It is mainly used for overload and short circuit protection.

Categories
Industrial Plug and Socket

Meba electric sockets MN6321

Meba electric sockets MN6321

Categories
Residual Current Circuit Breaker With Over Current Protection

Meba C65 2P function earth leakage circuit breaker MBR126C

Application:

1. C65NLE RCBO is used for the protection against electrical leakage in the circuit of 50Hz or 60Hz, rated voltage single-phase 230V, 3 phase 400V, rated current up to 60A.

2. When somebody gets an electric shock or the residual current of the circuit exceeds the fixed value, the ELCB can cut off the power within the time.

3. It is automatically to protect the personal safety and preventing the equipment from the fault resulted by the residual current.

4. With this function, the ELCB can protect the circuit against overload and short circuit or can be used for the unfrequent switchover of the circuit under normal conditions.

5. It conforms to IEC61009 standard.

Performance & Usage
Circuit breaker is mainly suitable for overload and short protection. It is especially used for illumination and distribution. It is of pleasing out-look, light weight, reliable performance, high breaking capacity, quick trip. etc.

 Frame class

1–60A

Rated working voltage

240/415V

Rated frequency

50/60Hz

Rated working current

16202532405063A

Rated residual operating current

0.03,0.1,0.3,0.5A

Rated residual un-operating current

0.015,0.05,0.15,0.25A

Sensibility

A TypeAC Type

Maximum operating time

In t≤0.1s , 5In t≤0.04

Rated making and breaking capacity

In≤50A 500A,In=63A 630A , In63A 1500A

Limiting value of un-operating current

6In

Rated limiting short-circuit current

3000A

Pole number

1/2/3/4P

Mechanical life

8000

Electric life

4000

 

Basic Data:

Constrcution and Feature

1)Protection against both overload and short circuit

2)High short-circuit capacity

3)Applicable to terminal and pin/fork type busbar connection

4)Easy mounting onto 35mm DIN rail

Technical Data

4)Pole No.: 1 . 1P+N .2 . 3 . 3P+N . 4 / 30mA

5)Rated Voltage : AC 230/400V~

6)Rated Current(A): 1,2,3,4,6,10,13,16,20,25,32,40,50,63

7)Tripping curve: B, C, D

8)Rated short-circuit capacity(Icn): 6KA

9)Rated frequency :50Hz/60Hz

10)Enerygy limiting class : 3

11)Rated impulse withstand voltage: 6.2kV

12)Electro-mechanical endurance : 4000

13)Connection terminal : srew terminal and pillar terminal with clamp

14)Connection capacity : Rigid conductor up to 25mm2

15)Fastenning torque: 2.0Nm

16)Installation: On symmetrical DIN rail 35mm /Panel Mounting

17)Terminal Connection Height: 19mm

 

Meba C65 2P function earth leakage circuit breaker MBR126C frame and parts adopt plastic of high inflammable resistance and shock resistance for long service life. It is mainly used for overload and short circuit protection.

Categories
Residual Current Circuit Breaker With Over Current Protection

Meba c65 elcb rcbo rccb earth leakage circuit breaker MBR136C

Application:

1. C65NLE RCBO is used for the protection against electrical leakage in the circuit of 50Hz or 60Hz, rated voltage single-phase 230V, 3 phase 400V, rated current up to 60A.

2. When somebody gets an electric shock or the residual current of the circuit exceeds the fixed value, the ELCB can cut off the power within the time.

3. It is automatically to protect the personal safety and preventing the equipment from the fault resulted by the residual current.

4. With this function, the ELCB can protect the circuit against overload and short circuit or can be used for the unfrequent switchover of the circuit under normal conditions.

5. It conforms to IEC61009 standard.

Performance & Usage
Circuit breaker is mainly suitable for overload and short protection. It is especially used for illumination and distribution. It is of pleasing out-look, light weight, reliable performance, high breaking capacity, quick trip. etc.

 Frame class

1–60A

Rated working voltage

240/415V

Rated frequency

50/60Hz

Rated working current

16202532405063A

Rated residual operating current

0.03,0.1,0.3,0.5A

Rated residual un-operating current

0.015,0.05,0.15,0.25A

Sensibility

A TypeAC Type

Maximum operating time

In t≤0.1s , 5In t≤0.04

Rated making and breaking capacity

In≤50A 500A,In=63A 630A , In63A 1500A

Limiting value of un-operating current

6In

Rated limiting short-circuit current

3000A

Pole number

1/2/3/4P

Mechanical life

8000

Electric life

4000

 

Basic Data:

Constrcution and Feature

1)Protection against both overload and short circuit

2)High short-circuit capacity

3)Applicable to terminal and pin/fork type busbar connection

4)Easy mounting onto 35mm DIN rail

Technical Data

4)Pole No.: 1 . 1P+N .2 . 3 . 3P+N . 4 / 30mA

5)Rated Voltage : AC 230/400V~

6)Rated Current(A): 1,2,3,4,6,10,13,16,20,25,32,40,50,63

7)Tripping curve: B, C, D

8)Rated short-circuit capacity(Icn): 6KA

9)Rated frequency :50Hz/60Hz

10)Enerygy limiting class : 3

11)Rated impulse withstand voltage: 6.2kV

12)Electro-mechanical endurance : 4000

13)Connection terminal : srew terminal and pillar terminal with clamp

14)Connection capacity : Rigid conductor up to 25mm2

15)Fastenning torque: 2.0Nm

16)Installation: On symmetrical DIN rail 35mm /Panel Mounting

17)Terminal Connection Height: 19mm

Meba c65 elcb rcbo rccb earth leakage circuit breaker MBR136C  frame and parts adopt plastic of high inflammable resistance and shock resistance for long service life. It is mainly used for overload and short circuit protection.

Categories
Thermal Overload Relay

Meba-electronic current relay switches-MBTH-22

Application

Meba electronic current relay switches MBTH-22 series thermal realy is suitable for using in power system with AC 50HZ,rated operation voltage up to 660A and 1000V,in main circuit,current from 0.1A to 630A.It is used to protect AC threephase asynchronous motor against overload and open-phase.The realys have the best push-button for breaking NC contacts and the operating indication and free trip characteristics.The products also can be supplied with protecting case to ensure safety .The products can be plug and install independently or mount by rail.

Technical Data

Categories
Thermal Overload Relay

Meba-overload motor switch-MB3UA-58

Application

Meba overload motor switch MB3UA-58 is suitable for using in power system with AC 50Hz, rated operation voltage up to 660V and 1000V, in main circuit, current from 0.1A to 630A. It is used to protect AC three-phase synchronous motor against overload and open-phase.

The relays have the test push-button for breaking NC contacts and the operating indicatino and free trip characteristics. The products also can be supplied with protecting case to ensure safety. The products can plug in the contactor and install independently or mount by rail.

Technical Data

Type Rated operating current(A) Rated insulation Voltage(V) Current setting range(A)
3UA50 12.5 660 0.1~0.16,0.16~0.25,0.25~4,0.32~0.63,0.63~0.1,0.8~1.25,1~1.16,1.25~2,1.6~2.5, 2~3.2, 2.5~4 ,3.2~5 ,4~6.3, 5~8 ,6.3~10 ,8~12.5
3UA52 25 660 0.1~0.16,0.16~0.25,0.25~ 0.4, 0.4~0.63 0.63~1, 0.8 ~1.25, 1~1.6, 1.25~2, 1.6~2.5,2~3.2,2.5~4, 3.2~5, 4~6.3, 5~8, 6.3~10, 8~12.5, 10~16, 12.5~20, 16~25
3UA54 32 660 4~6.3,6.3~10,10~16,12.5~20,16~25,20~32
3UA58 80 1000 16~25,20~32,25~40,32~50,40~57,50~63,57~70,63~80
3UA59 63 600 0.1~0.16, 0.16~0.25,0.25~0.4,0.4~0.63,0.63~1 0.8~1.25 ,1~1.6 ,1.25~2,1.6~2.5,2~3.2,2.5~4 3.2~5 ,4~6.3, 5~8, 6.3~10, 8~12.5, 10~16, 12.5~20, 16~25, 20~32 ,25~40 ,32~40, 32~45, 40~57,50~63
3UA62 180 660 55~80, 63~90, 80~110, 90~120, 110~135, 120~150, 135~160, 150~180,
3UA66 400 1000 80~125,125~200,180~250,200~320,250~400
3UA68 630 1000 320~500,400~630

electric motor overload protection relays
ISO9001 CERTIFICATE

Categories
Thermal Overload Relay

Meba-electric motor overload protection relays -MB3UA-52

Application

Meba electric motor overload protection relays  MB3UA-52 is suitable for using in power system with AC 50Hz, rated operation voltage up to 660V and 1000V, in main circuit, current from 0.1A to 630A. It is used to protect AC three-phase synchronous motor against overload and open-phase.

The relays have the test push-button for breaking NC contacts and the operating indicatino and free trip characteristics. The products also can be supplied with protecting case to ensure safety. The products can plug in the contactor and install independently or mount by rail.

Technical Data

Type Rated operating current(A) Rated insulation Voltage(V) Current setting range(A)
3UA50 12.5 660 0.1~0.16,0.16~0.25,0.25~4,0.32~0.63,0.63~0.1,0.8~1.25,1~1.16,1.25~2,1.6~2.5, 2~3.2, 2.5~4 ,3.2~5 ,4~6.3, 5~8 ,6.3~10 ,8~12.5
3UA52 25 660 0.1~0.16,0.16~0.25,0.25~ 0.4, 0.4~0.63 0.63~1, 0.8 ~1.25, 1~1.6, 1.25~2, 1.6~2.5,2~3.2,2.5~4, 3.2~5, 4~6.3, 5~8, 6.3~10, 8~12.5, 10~16, 12.5~20, 16~25
3UA54 32 660 4~6.3,6.3~10,10~16,12.5~20,16~25,20~32
3UA58 80 1000 16~25,20~32,25~40,32~50,40~57,50~63,57~70,63~80
3UA59 63 600 0.1~0.16, 0.16~0.25,0.25~0.4,0.4~0.63,0.63~1 0.8~1.25 ,1~1.6 ,1.25~2,1.6~2.5,2~3.2,2.5~4 3.2~5 ,4~6.3, 5~8, 6.3~10, 8~12.5, 10~16, 12.5~20, 16~25, 20~32 ,25~40 ,32~40, 32~45, 40~57,50~63
3UA62 180 660 55~80, 63~90, 80~110, 90~120, 110~135, 120~150, 135~160, 150~180,
3UA66 400 1000 80~125,125~200,180~250,200~320,250~400
3UA68 630 1000 320~500,400~630

electric motor overload protection relays
ISO9001 CERTIFICATE

Categories
Thermal Overload Relay

Meba-thermal protection-MBTH-85

Application

Meba thermal protection MBTH-85  series thermal realy is suitable for using in power system with AC 50HZ,rated operation voltage up to 660A and 1000V,in main circuit,current from 0.1A to 630A.It is used to protect AC threephase asynchronous motor against overload and open-phase.The realys have the best push-button for breaking NC contacts and the operating indication and free trip characteristics.The products also can be supplied with protecting case to ensure safety .The products can be plug and install independently or mount by rail.

Technical Data

Categories
Residual Current Circuit Breaker With Over Current Protection

Meba Residual current with over current pretection C65 RCBO MBR516C

Application:

1. C65NLE RCBO is used for the protection against electrical leakage in the circuit of 50Hz or 60Hz, rated voltage single-phase 230V, 3 phase 400V, rated current up to 60A.

2. When somebody gets an electric shock or the residual current of the circuit exceeds the fixed value, the ELCB can cut off the power within the time.

3. It is automatically to protect the personal safety and preventing the equipment from the fault resulted by the residual current.

4. With this function, the ELCB can protect the circuit against overload and short circuit or can be used for the unfrequent switchover of the circuit under normal conditions.

5. It conforms to IEC61009 standard.

Performance & Usage
Circuit breaker is mainly suitable for overload and short protection. It is especially used for illumination and distribution. It is of pleasing out-look, light weight, reliable performance, high breaking capacity, quick trip. etc.

[tab_item title=”Technical Parameter”]

 Frame class

1–60A

Rated working voltage

240/415V

Rated frequency

50/60Hz

Rated working current

16202532405063A

Rated residual operating current

0.03,0.1,0.3,0.5A

Rated residual un-operating current

0.015,0.05,0.15,0.25A

Sensibility

A TypeAC Type

Maximum operating time

In t≤0.1s , 5In t≤0.04

Rated making and breaking capacity

In≤50A 500A,In=63A 630A , In63A 1500A

Limiting value of un-operating current

6In

Rated limiting short-circuit current

3000A

Pole number

1/2/3/4P

Mechanical life

8000

Electric life

4000

 

Basic Data:

Constrcution and Feature

1)Protection against both overload and short circuit

2)High short-circuit capacity

3)Applicable to terminal and pin/fork type busbar connection

4)Easy mounting onto 35mm DIN rail

Technical Data

4)Pole No.: 1 . 1P+N .2 . 3 . 3P+N . 4 / 30mA

5)Rated Voltage : AC 230/400V~

6)Rated Current(A): 1,2,3,4,6,10,13,16,20,25,32,40,50,63

7)Tripping curve: B, C, D

8)Rated short-circuit capacity(Icn): 6KA

9)Rated frequency :50Hz/60Hz

10)Enerygy limiting class : 3

11)Rated impulse withstand voltage: 6.2kV

12)Electro-mechanical endurance : 4000

13)Connection terminal : srew terminal and pillar terminal with clamp

14)Connection capacity : Rigid conductor up to 25mm2

15)Fastenning torque: 2.0Nm

16)Installation: On symmetrical DIN rail 35mm /Panel Mounting

17)Terminal Connection Height: 19mm

Meba Residual current with over current pretection C65 RCBO MBR516C frame and parts adopt plastic of high inflammable resistance and shock resistance for long service life. It is mainly used for overload and short circuit protection.

Categories
Thermal Overload Relay

Meba-thermal overload motoring relay-MBTH-40

Application

Meba thermal overload motoring relay MBTH-40  series thermal realy is suitable for using in power system with AC 50HZ,rated operation voltage up to 660A and 1000V,in main circuit,current from 0.1A to 630A.It is used to protect AC threephase asynchronous motor against overload and open-phase.The realys have the best push-button for breaking NC contacts and the operating indication and free trip characteristics.The products also can be supplied with protecting case to ensure safety .The products can be plug and install independently or mount by rail.

Technical Data

The TH series thermal relay protects the motors Overload, Locking, Open phase (differential) CHARACTERISTICS

*Direct mounting structure

The GTH is mounting directly to the Magnetic Contactors without addition brackets.(Applied model:model:TH-22,40,85)

*Safety cover

The finger proof safety cover prevent careless touch of electric conductor(Applied model:TH-22,40,85)

*Separation of power part and operation part

The main circuit and the operation part are separately designed and the operation part is commonly used in TH-22, 40, 85

*Easy operation

Categories
Residual Current Circuit Breaker With Over Current Protection

Meba rcbo circuit breaker MBR3410C

General

1.1Function
Personnel and fire protection
Cable and line protection against overload and short-circuits.

1.2 Selection
I∆n ≤ 30 mA: additional protection
In the case of direct contact.
I∆n ≤ 300 mA: preventative fire protection
In the case of ground fault currents.
AC class – Tripping is ensured for sinusoidal,
Alternating currents, whether they be quickly applied or slowly increase.

1.3 Performance & Usage
Circuit breaker is mainly suitable for overload and short protection. It is especially used for illumination and distribution. It is of pleasing out-look, light weight, reliable performance, high breaking capacity, quick trip. etc.

Standard

IEC60898

Type(wave form of the earth leakage sensed)

AC

Thermo-magnetic release characteristic

8-12In

Number of poles

1P+N, 2P, 3P,3P+N, 4P

Rated current(In)

63, 80, 100

Rated sensitivity I∆n

0.03, 0.1, 0.3A

Rated residual making and breaking capacity I∆n

2000A

Rated short-circuit capacity Icn

6000A

Break time under I∆n

≤0.1S

Rated frequency

50Hz

Rated impulse withstand voltage(1.2/50) Uimp

4000V

Dielectric TEST voltage, Freq for 1min

2.0Kv

Insulated voltage UI

500V

Pollution degree

3

Electrical life

1500

Mechanical life

8500

Contact position indicator

Yes

Protection degree

IP20

Ambient temperature

(with daily average≤35℃)

-5~+40℃

Storage temperature

-25~+70℃

Terminal connection type

Cable/Pin-type busbar

Terminal size top/bottom for cable

16~50mm²

6-1/10AWG

Terminal size top/bottom for busbar

16~35mm²

6-2AWG

Tightening torque

3.5 N*m

31 In-Ibs

Mounting connection

On din rail EN60715(35mm) by means of fast dip device from top

Meba rcbo circuit breaker MBR3410C frame and parts adopt plastic of high inflammable resistance and shock resistance for long service life. It is mainly used for overload and short circuit protection.

Categories
Residual Current Circuit Breaker With Over Current Protection

Meba Eatch leakage Circuit Breaker RCBO MBR3310C

General

1.1Function
Personnel and fire protection
Cable and line protection against overload and short-circuits.

1.2 Selection
I∆n ≤ 30 mA: additional protection
In the case of direct contact.
I∆n ≤ 300 mA: preventative fire protection
In the case of ground fault currents.
AC class – Tripping is ensured for sinusoidal,
Alternating currents, whether they be quickly applied or slowly increase.

1.3 Performance & Usage
Circuit breaker is mainly suitable for overload and short protection. It is especially used for illumination and distribution. It is of pleasing out-look, light weight, reliable performance, high breaking capacity, quick trip. etc.

Standard

IEC60898

Type(wave form of the earth leakage sensed)

AC

Thermo-magnetic release characteristic

8-12In

Number of poles

1P+N, 2P, 3P,3P+N, 4P

Rated current(In)

63, 80, 100

Rated sensitivity I∆n

0.03, 0.1, 0.3A

Rated residual making and breaking capacity I∆n

2000A

Rated short-circuit capacity Icn

6000A

Break time under I∆n

≤0.1S

Rated frequency

50Hz

Rated impulse withstand voltage(1.2/50) Uimp

4000V

Dielectric TEST voltage, Freq for 1min

2.0Kv

Insulated voltage UI

500V

Pollution degree

3

Electrical life

1500

Mechanical life

8500

Contact position indicator

Yes

Protection degree

IP20

Ambient temperature

(with daily average≤35℃)

-5~+40℃

Storage temperature

-25~+70℃

Terminal connection type

Cable/Pin-type busbar

Terminal size top/bottom for cable

16~50mm²

6-1/10AWG

Terminal size top/bottom for busbar

16~35mm²

6-2AWG

Tightening torque

3.5 N*m

31 In-Ibs

Mounting connection

On din rail EN60715(35mm) by means of fast dip device from top

 

Meba Eatch leakage Circuit Breaker RCBO MBR3310C  frame and parts adopt plastic of high inflammable resistance and shock resistance for long service life. It is mainly used for overload and short circuit protection.

Categories
Residual Current Circuit Breaker With Over Current Protection

Meba Residual current operated circuit breaker MBR3210C

General

1.1Function
Personnel and fire protection
Cable and line protection against overload and short-circuits.

1.2 Selection
I∆n ≤ 30 mA: additional protection
In the case of direct contact.
I∆n ≤ 300 mA: preventative fire protection
In the case of ground fault currents.
AC class – Tripping is ensured for sinusoidal,
Alternating currents, whether they be quickly applied or slowly increase.

1.3 Performance & Usage
Circuit breaker is mainly suitable for overload and short protection. It is especially used for illumination and distribution. It is of pleasing out-look, light weight, reliable performance, high breaking capacity, quick trip. etc.

Standard

IEC60898

Type(wave form of the earth leakage sensed)

AC

Thermo-magnetic release characteristic

8-12In

Number of poles

1P+N, 2P, 3P,3P+N, 4P

Rated current(In)

63, 80, 100

Rated sensitivity I∆n

0.03, 0.1, 0.3A

Rated residual making and breaking capacity I∆n

2000A

Rated short-circuit capacity Icn

6000A

Break time under I∆n

≤0.1S

Rated frequency

50Hz

Rated impulse withstand voltage(1.2/50) Uimp

4000V

Dielectric TEST voltage, Freq for 1min

2.0Kv

Insulated voltage UI

500V

Pollution degree

3

Electrical life

1500

Mechanical life

8500

Contact position indicator

Yes

Protection degree

IP20

Ambient temperature

(with daily average≤35℃)

-5~+40℃

Storage temperature

-25~+70℃

Terminal connection type

Cable/Pin-type busbar

Terminal size top/bottom for cable

16~50mm²

6-1/10AWG

Terminal size top/bottom for busbar

16~35mm²

6-2AWG

Tightening torque

3.5 N*m

31 In-Ibs

Mounting connection

On din rail EN60715(35mm) by means of fast dip device from top

Meba Residual current operated circuit breaker MBR3210C frame and parts adopt plastic of high inflammable resistance and shock resistance for long service life. It is mainly used for overload and short circuit protection.

Categories
Thermal Overload Relay

Meba-designed thermal relay-MB3UA-66

Application

Meba designed thermal relay MB3UA-66 series thermal realy is suitable for using in power system with AC 50HZ,rated operation voltage up to 660A and 1000V,in main circuit,current from 0.1A to 630A.It is used to protect AC threephase asynchronous motor against overload and open-phase.The realys have the best push-button for breaking NC contacts and the operating indication and free trip characteristics.The products also can be supplied with protecting case to ensure safety .The products can be plug and install independently or mount by rail.

Technical Data

Type Rated insulation

voltage(V)

    Rated working current

of thermal relay(A)

Rated current

Rated(A)

Rated or scale of rated current(A)
MB3UA-63 660 63 3UA-59 0.16 0.1~0.16
0.25 0.16~0.25
0.4 0.25~0.4
0.63 0.4~0.63
1.0 0.63~1
1.25 0.8~1.25
1.60 1~1.60
2.0 1.25~2
2.5 1.6~2.5
3.2 2~3.2
4.0 2.5~4
5.0 3.2~5
6.3 4~6.3
8.0 5~8
10.0  6.3~10
12.5  8~12.5
16.0 10~16
20.0  12.5~20
25.0 16~25
32.0 20~32
40.0 25~40
45.0 32~45
57.0  40~57
63.0 50~63
MB3UA-120 660 120 3UA-60 80.0 55~80
90.0  63~90
110.0  80~110
120.0  90~120
135.0  110~135
MB3UA-150 660 150 3UA-61 80.0 55~80
90.0 63~90
110.0 80~110
120.0 90~120
135.0 110~135
150.0 120~150
MB3UA-180 660 180 3UA-62 80.0 55~80
90.0 63~90
110.0 80~110
120.0 90~120
135.0 110~135
150.0 120~150
160.0 130~160
 180.0 150~180
MB3UA-400 1000 400 3UA-66  125.0 80~125
 200.0 125~200
 250.0 160~250
 320.0 200~320
 400.0 250~400
MB3UA-630 1000 630 3UA-68  500.0 320~500
 630.0 400~630
Categories
Industrial Plug and Socket

Meba electric socket MN6312

Meba electric socket MN6312

Categories
Industrial Plug and Socket

Meba electric outlet MN6331

Meba electric outlet MN6331

Categories
Industrial Plug and Socket

Meba electric light socket MN6322

Meba electric light socket MN6322

Meba electric light socket MN6322

Technical Parameter:
Categories
Industrial Plug and Socket

Meba electrical sockets MN6341

Meba electrical sockets MN6341

Categories
Industrial Plug and Socket

Meba electrical sockets MN1312

Meba electrical sockets MN1312