Categories
Air Conditioner Contactor

Meba Air Conditioner Contactor Relay MBK3-3P30A

Meba Air Conditioner Contactor Relay MBK3-3P30A

Meba Air Conditioner Contactor Relay MBK3-3P30A This series contactor is mainly applicable to a line of AC 50Hz or 60Hz, rated working voltage up to 600V and rated working current up to 60A, used to close or and to switch off the line. It complies to IEC947-4-1.

Meba Air Conditioner Contactor Relay MBK3-3P30A Feature: 1.Low VA coil for cooler operation and increased life. 2.Quiet operation 3.Universal style mounting bracket fits existing mounting holes. 4. Double break contacts ensure positive make and break. 5. Screw terminals or pressure connectors and double 1/4 quick connects provided on all models for easy installation Technical Parameter:

Coil rating 1Pole contactors 2 pole contacts
Nominal coil voltage 24 120 208/240 277 24 120 208/240 277
Nominal coil resistance Ohms 18 420 1800 2500 11 237 1000 1600
Maximum pick up voltage 18 88 177 221 18 88 177 221
Maximum drop out voltage 6-15 20-70 40-140 50-165 6-15 20-70 40-140 50-165
Nominal rush Va@50Hz 31 31 31 31 33 33 33 33
Nominal rush Va@60Hz 28 28 28 28 30 30 30 30
Nominal rush Va@50Hz 6 6 6 6 8 8 8 8
Nominal rush Va@60Hz 5 5 5 5 6.5 6.5 6.5 6.5
Maximum coil voltage 30 132 264 300 30 132 132 300
Categories
Air Conditioner Contactor

Meba air conditioner contactor MBK3-1P30A

Meba air conditioner contactor MBK3-1P30A

Meba air conditioner contactor MBK3-1P30A This series contactor is mainly applicable to a line of AC 50Hz or 60Hz, rated working voltage up to 600V and rated working current up to 60A, used to close or and to switch off the line. It complies to IEC947-4-1.

Meba air conditioner contactor MBK3-1P30A

Feature:

1.Low VA coil for cooler operation and increased life.
2.Quiet operation
3.Universal style mounting bracket fits existing mounting holes.
4. Double break contacts ensure positive make and break.
5. Screw terminals or pressure connectors and double 1/4 quick connects provided on all models for easy installation

Technical Parameter:

Coil rating 1Pole contactors 2 pole contacts
Norminal coil voltage 24 120 208/240 277 24 120 208/240 277
Norminal coil resistance Ohms 18 420 1800 2500 11 237 1000 1600
Maximum pick up voltage 18 88 177 221 18 88 177 221
Maximum drop out voltage 6-15 20-70 40-140 50-165 6-15 20-70 40-140 50-165
Norminal rush Va@50Hz 31 31 31 31 33 33 33 33
Norminal rush Va@60Hz 28 28 28 28 30 30 30 30
Norminal rush Va@50Hz 6 6 6 6 8 8 8 8
Norminal rush Va@60Hz 5 5 5 5 6.5 6.5 6.5 6.5
Maximum coil voltage 30 132 264 300 30 132 132 300
Categories
Air Conditioner Contactor

Meba air conditioner contact MBK3-1P40A

Meba air conditioner contact MBK3-1P40A

Meba air conditioner contact MBK3-1P40A  This series contactor is mainly applicable to a line of AC 50Hz or 60Hz, rated working voltage up to 600V and rated working current up to 60A, used to close or and to switch off the line. It complies to IEC947-4-1.

Meba air conditioner contact MBK3-1P40A

Feature:

1.Low VA coil for cooler operation and increased life.
2.Quiet operation
3.Universal style mounting bracket fits existing mounting holes.
4. Double break contacts ensure positive make and break.
5. Screw terminals or pressure connectors and double 1/4 quick connects provided on all models for easy installation

Technical Parameter:

Coil rating 1Pole contactors 2 pole contacts
Nominal coil voltage 24 120 208/240 277 24 120 208/240 277
Nominal coil resistance Ohms 18 420 1800 2500 11 237 1000 1600
Maximum pick up voltage 18 88 177 221 18 88 177 221
Maximum drop out voltage 6-15 20-70 40-140 50-165 6-15 20-70 40-140 50-165
Nominal rush Va@50Hz 31 31 31 31 33 33 33 33
Nominal rush Va@60Hz 28 28 28 28 30 30 30 30
Nominal rush Va@50Hz 6 6 6 6 8 8 8 8
Nominal rush Va@60Hz 5 5 5 5 6.5 6.5 6.5 6.5
Maximum coil voltage 30 132 264 300 30 132 132 300
Categories
Magnetic AC Contactor

Meba magnetic contactor MBK09

Meba magnetic contactor MBK09

Meba magnetic contactor MBK09  is suitable for using in the circuit up to the rated voltage 660 AC 50Hz/60Hz,rated current up to 09A,for frequent starting,controlling the AC motor.The addition of auxiliary contact group to the contactor,combined with the proper thermo relay,can act to protect the circuit bound to overload,Contactor designed by traverse double breaking points,blocking and zero flash-over,it has characteristic of multi-functional combination,small volume and reliability,and can replace LC1-K,LC1-E series of TE company,products have been widely applied to signal magnifying switch in micro-electronic interface.

Meba magnetic contactor MBK09:

Technical Parameter:

Type Rated operating current (A) AC-3Use Group ContactNumber
Control power KW
220V 380/415V 440/500V 600V
LC1-K06 6 1.5 2.2 3 3 3P+NC3P+NO
LC1-K09 9 2.2 4 4 4 3P+NC3P+NO
LC1-K12 12 3 5 5 5 3P+NC3P+NO
Categories
Magnetic AC Contactor

Meba magnetic contactor wiring MBMC-85

Meba magnetic contactor wiring MBMC-85

Meba magnetic contactor wiring MBMC-85 are suitable for frequency 50/60Hz,rated insulation voltage up to 1000V,rated operation current 85A  under AC-3 duty. It is mainly used for breaking electric circuits at a long distance and for frequent starting, stopping & controlling AC Motors. It is used in combination with thermal relay to compose a magnetic motor starter. The products comply with IEC60947-4.

Meba magnetic contactor wiring MBMC-85

Features:

1. Made up of by 2 same type AC contactors of LC2-D interlocked by machine interlock
2 .Machine interlock doesn’t affect the action time of AC contactor.
3. Products loops,assistant loop lead connected (the products not connected with lead supply)
4. Close frame and reliable interlock

Techinical Parameter:

Type

Number of poles

Rate current (DC2,DC4)DC motor load(L/R=115MS)

Rate current(DC1) DC motor load(L/R=1MS)

Rate current(DC1)Coil load (L/R=100MS)

24V

48V

110V

220V

24V

48V

110V

220V

24V

48V

110V

220V

MBMC-9

2

8

4

2.5

0.8

10

10

6

3

8

4

2

0.3

3

8

6

4

2

10

10

8

8

8

6

3

0.8

MBMC-12

2

12

6

4

1.2

12

12

10

7

12

6

3

0.5

3

12

10

8

4

12

12

12

12

12

10

5

2

MBMC-18

2

12

6

4

1.2

18

18

13

8

12

6

3

0.5

3

12

10

8

4

18

18

18

18

12

10

5

2

MBMC-22

2

20

15

8

2

20

20

15

10

20

12

3

1.2

3

20

20

15

8

20

20

20

20

20

15

10

4

MBMC-32

2

25

20

10

3

25

25

25

12

25

15

4

1.2

3

25

25

20

10

25

25

25

22

25

25

12

4

MBMC-40

2

35

20

10

3.5

25

25

25

12

35

15

4

1.2

3

35

30

20

12

35

35

35

30

35

25

12

4

MBMC-50

2

45

25

15

3.5

40

40

35

15

3

50

35

30

12

50

50

50

40

MBMC-65

2

45

25

15

3.5

40

40

35

15

3

50

35

30

12

65

65

65

50

MBMC-75

2

65

40

20

5

65

65

50

20

3

80

60

50

20

75

75

75

55

MBMC-85

2

65

40

20

5

65

65

50

20

3

80

60

50

20

80

80

80

60

MBMC-100

2

100

90

40

30

100

100

80

50

3

100

90

80

50

100

100

100

80

MBMC-125

2

120

60

40

30

100

100

80

50

3

120

90

80

50

120

120

100

80

MBMC-150

2

150

100

80

60

120

120

100

100

3

150

130

120

80

150

150

150

150

MBMC-180

2

180

150

120

80

180

180

150

150

3

180

180

150

100

180

180

180

180

MBMC-220

2

220

150

120

80

180

180

150

150

3

220

220

150

100

220

220

220

220

MBMC-300

2

300

200

150

90

240

240

200

200

3

300

280

200

150

300

300

300

300

MBMC-400

2

400

200

150

90

240

240

200

200

3

400

280

200

150

400

400

400

300

MBMC-600

2

630

630

630

630

630

630

630

630

3

630

630

630

630

630

630

630

630

MBMC-800

2

800

630

630

630

800

800

630

630

3

800

630

630

630

800

800

680

800

Categories
Magnetic AC Contactor

Meba magnetic contactor switch MBMC-150

Meba magnetic contactor switch MBMC-150

Meba magnetic contactor switch MBMC-150 are suitable for frequency 50/60Hz,rated insulation voltage up to 1000V,rated operation current 150A under AC-3 duty. It is mainly used for breaking electric circuits at a long distance and for frequent starting, stopping & controlling AC Motors. It is used in combination with thermal relay to compose a magnetic motor starter. The products comply with IEC60947-4.

Meba magnetic contactor switch MBMC-150

Features:

1. Made up of by 2 same type AC contactors of LC2-D interlocked by machine interlock
2 .Machine interlock doesn’t affect the action time of AC contactor.
3. Products loops,assistant loop lead connected (the products not connected with lead supply)
4. Close frame and reliable interlock

Techinical Parameter:

Type

Number of poles

Rate current (DC2,DC4)DC motor load(L/R=115MS)

Rate current(DC1) DC motor load(L/R=1MS)

Rate current(DC1)Coil load (L/R=100MS)

24V

48V

110V

220V

24V

48V

110V

220V

24V

48V

110V

220V

MBMC-9

2

8

4

2.5

0.8

10

10

6

3

8

4

2

0.3

3

8

6

4

2

10

10

8

8

8

6

3

0.8

MBMC-12

2

12

6

4

1.2

12

12

10

7

12

6

3

0.5

3

12

10

8

4

12

12

12

12

12

10

5

2

MBMC-18

2

12

6

4

1.2

18

18

13

8

12

6

3

0.5

3

12

10

8

4

18

18

18

18

12

10

5

2

MBMC-22

2

20

15

8

2

20

20

15

10

20

12

3

1.2

3

20

20

15

8

20

20

20

20

20

15

10

4

MBMC-32

2

25

20

10

3

25

25

25

12

25

15

4

1.2

3

25

25

20

10

25

25

25

22

25

25

12

4

MBMC-40

2

35

20

10

3.5

25

25

25

12

35

15

4

1.2

3

35

30

20

12

35

35

35

30

35

25

12

4

MBMC-50

2

45

25

15

3.5

40

40

35

15

wiring diagram MBMC

3

50

35

30

12

50

50

50

40

MBMC-65

2

45

25

15

3.5

40

40

35

15

3

50

35

30

12

65

65

65

50

MBMC-75

2

65

40

20

5

65

65

50

20

3

80

60

50

20

75

75

75

55

MBMC-85

2

65

40

20

5

65

65

50

20

3

80

60

50

20

80

80

80

60

MBMC-100

2

100

90

40

30

100

100

80

50

3

100

90

80

50

100

100

100

80

MBMC-125

2

120

60

40

30

100

100

80

50

3

120

90

80

50

120

120

100

80

MBMC-150

2

150

100

80

60

120

120

100

100

3

150

130

120

80

150

150

150

150

MBMC-180

2

180

150

120

80

180

180

150

150

3

180

180

150

100

180

180

180

180

MBMC-220

2

220

150

120

80

180

180

150

150

3

220

220

150

100

220

220

220

220

MBMC-300

2

300

200

150

90

240

240

200

200

3

300

280

200

150

300

300

300

300

MBMC-400

2

400

200

150

90

240

240

200

200

3

400

280

200

150

400

400

400

300

MBMC-600

2

630

630

630

630

630

630

630

630

3

630

630

630

630

630

630

630

630

MBMC-800

2

800

630

630

630

800

800

630

630

3

800

630

630

630

800

800

680

800

Categories
Magnetic AC Contactor

Meba magnetic contactor diagram MBMC-09

Meba magnetic contactor diagram MBMC-09

Meba magnetic contactor diagram MBMC-09 are suitable for frequency 50/60Hz,rated insulation voltage up to 1000V,rated operation current 9A under AC-3 duty. It is mainly used for breaking electric circuits at a long distance and for frequent starting, stopping & controlling AC Motors. It is used in combination with thermal relay to compose a magnetic motor starter. The products comply with IEC60947-4.

Meba magnetic contactor diagram MBMC-09

Features:
1. Made up of by 2 same type AC contactors of LC2-D interlocked by machine interlock
2 .Machine interlock doesn’t affect the action time of AC contactor.
3. Products loops,assistant loop lead connected (the products not connected with lead supply)
4. Close frame and reliable interlock

Techinical Parameter:

Type

Number of poles

Rate current (DC2,DC4)DC motor load(L/R=115MS)

Rate current(DC1) DC motor load(L/R=1MS)

Rate current(DC1)Coil load (L/R=100MS)

24V

48V

110V

220V

24V

48V

110V

220V

24V

48V

110V

220V

MBMC-9

2

8

4

2.5

0.8

10

10

6

3

8

4

2

0.3

3

8

6

4

2

10

10

8

8

8

6

3

0.8

MBMC-12

2

12

6

4

1.2

12

12

10

7

12

6

3

0.5

3

12

10

8

4

12

12

12

12

12

10

5

2

MBMC-18

2

12

6

4

1.2

18

18

13

8

12

6

3

0.5

3

12

10

8

4

18

18

18

18

12

10

5

2

MBMC-22

2

20

15

8

2

20

20

15

10

20

12

3

1.2

3

20

20

15

8

20

20

20

20

20

15

10

4

MBMC-32

2

25

20

10

3

25

25

25

12

25

15

4

1.2

3

25

25

20

10

25

25

25

22

25

25

12

4

MBMC-40

2

35

20

10

3.5

25

25

25

12

35

15

4

1.2

3

35

30

20

12

35

35

35

30

35

25

12

4

MBMC-50

2

45

25

15

3.5

40

40

35

15

50

50

40

MBMC-65

2

45

25

15

3.5

40

40

35

15

3

50

35

30

12

65

65

65

50

MBMC-75

2

65

40

20

5

65

65

50

20

3

80

60

50

20

75

75

75

55

MBMC-85

2

65

40

20

5

65

65

50

20

3

80

60

50

20

80

80

80

60

MBMC-100

2

100

90

40

30

100

100

80

50

3

100

90

80

50

100

100

100

80

MBMC-125

2

120

60

40

30

100

100

80

50

3

120

90

80

50

120

120

100

80

MBMC-150

2

150

100

80

60

120

120

100

100

3

150

130

120

80

150

150

150

150

MBMC-180

2

180

150

120

80

180

180

150

150

3

180

180

150

100

180

180

180

180

MBMC-220

2

220

150

120

80

180

180

150

150

3

220

220

150

100

220

220

220

220

MBMC-300

2

300

200

150

90

240

240

200

200

3

300

280

200

150

300

300

300

300

MBMC-400

2

400

200

150

90

240

240

200

200

3

400

280

200

150

400

400

400

300

MBMC-600

2

630

630

630

630

630

630

630

630

3

630

630

630

630

630

630

630

630

MBMC-800

2

800

630

630

630

800

800

630

630

3

800

630

630

630

800

800

680

800

Categories
Magnetic AC Contactor

Meba magnetic contactor diagram MBMC-32

Meba magnetic contactor diagram MBMC-32

Meba magnetic contactor diagram MBMC-32 are suitable for frequency 50/60Hz,rated insulation voltage up to 1000V,rated operation current 32A under AC-3 duty. It is mainly used for breaking electric circuits at a long distance and for frequent starting, stopping & controlling AC Motors. It is used in combination with thermal relay to compose a magnetic motor starter. The products comply with IEC60947-4.

Meba magnetic contactor diagram MBMC-32

Features:

1. Made up of by 2 same type AC contactors of LC2-D interlocked by machine interlock
2 .Machine interlock doesn’t affect the action time of AC contactor.
3. Products loops,assistant loop lead connected (the products not connected with lead supply)
4. Close frame and reliable interlock

Techinical Parameter:

Type

Number of poles

Rate current (DC2,DC4)DC motor load(L/R=115MS)

Rate current(DC1) DC motor load(L/R=1MS)

Rate current(DC1)Coil load (L/R=100MS)

24V

48V

110V

220V

24V

48V

110V

220V

24V

48V

110V

220V

MBMC-9

2

8

4

2.5

0.8

10

10

6

3

8

4

2

0.3

3

8

6

4

2

10

10

8

8

8

6

3

0.8

MBMC-12

2

12

6

4

1.2

12

12

10

7

12

6

3

0.5

3

12

10

8

4

12

12

12

12

12

10

5

2

MBMC-18

2

12

6

4

1.2

18

18

13

8

12

6

3

0.5

3

12

10

8

4

18

18

18

18

12

10

5

2

MBMC-22

2

20

15

8

2

20

20

15

10

20

12

3

1.2

3

20

20

15

8

20

20

20

20

20

15

10

4

MBMC-32

2

25

20

10

3

25

25

25

12

25

15

4

1.2

3

25

25

20

10

25

25

25

22

25

25

12

4

MBMC-40

2

35

20

10

3.5

25

25

25

12

35

15

4

1.2

3

35

30

20

12

35

35

35

30

35

25

12

4

MBMC-50

2

45

25

15

3.5

40

40

35

15

3

50

35

30

12

50

50

50

40

MBMC-65

2

45

25

15

3.5

40

40

35

15

3

50

35

30

12

65

65

65

50

MBMC-75

2

65

40

20

5

65

65

50

20

3

80

60

50

20

75

75

75

55

MBMC-85

2

65

40

20

5

65

65

50

20

3

80

60

50

20

80

80

80

60

MBMC-100

2

100

90

40

30

100

100

80

50

3

100

90

80

50

100

100

100

80

MBMC-125

2

120

60

40

30

100

100

80

50

3

120

90

80

50

120

120

100

80

MBMC-150

2

150

100

80

60

120

120

100

100

3

150

130

120

80

150

150

150

150

MBMC-180

2

180

150

120

80

180

180

150

150

3

180

180

150

100

180

180

180

180

MBMC-220

2

220

150

120

80

180

180

150

150

3

220

220

150

100

220

220

220

220

MBMC-300

2

300

200

150

90

240

240

200

200

3

300

280

200

150

300

300

300

300

MBMC-400

2

400

200

150

90

240

240

200

200

3

400

280

200

150

400

400

400

300

MBMC-600

2

630

630

630

630

630

630

630

630

3

630

630

630

630

630

630

630

630

MBMC-800

2

800

630

630

630

800

800

630

630

3

800

630

630

630

800

800

680

800

Categories
Magnetic AC Contactor

Meba electrical contactors MB1SD40

Meba electrical contactors MB1SD40

Meba electrical contactors MB1SD40 Series machine interlock contactors are suitable for using in AC 50/60Hz and rating insulation voltage 690-1000V,rating voltage 380V,rating current 9A-150A under AC-3.and control the positive and negative rotation of motor. Contactors conform with IEC6094741,VDE0660 GB14048.4 and etc.

Meba electrical contactors MB1SD40
Features:
1. Made up of by 2 same type AC contactors of LC2-D interlocked by machine interlock
2 .Machine interlock doesn’t affect the action time of AC contactor.
3. Products loops,assistant loop lead connected (the products not connected with lead supply)
4. Close frame and reliable interlock
Technical Parameter:

Type

Rated current
AC-3

Controlled power(kw)

220V

380V

415V

415V

660V

MB1SD-09

9

2.2

4

4

4

5.5

MB1SD-12

12

5.5

5.5

5.5

5.5

7.5

                  MB1SD-18

16

7.5

7.5

9

9

10

MB1SD-25

25

5.5

11

11

11

15

MB1SD-32

32

7.5

15

15

15

18.5

MB1SD-4011

40

18.5

18.5

22

22

30

MB1SD-5011

50

15

22

25

30

33

MB1SD -6511

63

18.5

30

37

37

37

MB1SD -8011

80

22

37

45

45

45

MB1SD -9511

95

22

45

45

45

41

Categories
Magnetic AC Contactor

Meba electrical contactor MB2SD09

Meba electrical contactor MB2SD09

Meba electrical contactor MB2SD09 AC contactors are suitable for frequency 50/60Hz,rated insulation voltage up to 1000V,rated operation current 9~150A under AC-3 duty. It is mainly used for breaking electric circuits at a long distance and for frequent starting, stopping & controlling AC Motors. It is used in combination with thermal relay to compose a magnetic motor starter. The products comply with IEC60947-4.

Meba electrical contactor MB2SD09
Features:
1. Made up of by 2 same type AC contactors of LC2-D interlocked by machine interlock
2 .Machine interlock doesn’t affect the action time of AC contactor.
3. Products loops,assistant loop lead connected (the products not connected with lead supply)
4. Close frame and reliable interlock
Technical Parameter:

Type

Rated Power KW/HP( AC-3 )IEC60947-4-1 GB14048.4

Rated Current A(AC-3) IEC60947-4-1 GB14048.4

Rated Heating Current Ith:(A)

Rated Insulated Voltage Ui:(V)

Auxiliary Contact AC-15

Electrical/Mechanic Life (Million Times)

Contact Arrangement

Rated Current (A)(AC-3) IEC60947-4-1 GB14048.4

Rated Heating Current Ith:(A)

200-220V

380-
440V

500-550V

200-220V

380-
440V

500-550V

Standard

Special

200-220V

380-
440V

MB2SD-D09
new

2.2/3

4/5.5

5/7

11

9

7

18

660

1NO+1NC

/

1.6

0.95

16

1/5

MB2SD-D12
new

3/4

5.5/7.5

7.5/10

15

12

9

18

660

1NO+1NC

/

1.6

0.95

16

MB2SD-D18
new

4/5.5

7.5/10

9/12

22

18

12

25

660

1NO+1NC

/

1.6

0.95

16

MB2SD-D25
new

5.5/7.5

11/15

15/20

30

25

18

40

660

1NO+1NC

/

1.6

0.95

16

MB2SD-D32
new

7.5/10

15/20

18.5/2540

40

32

21

40

660

1NO+1NC

/

1.6

0.95

16

MB2SD-D40
new

11/15

18.5/25

30/40

50

40

34

60

660

1NO+1NC

/

1.6

0.95

16

MB2SD-D50
new

15/20

22/30

37/50

60

50

39

80

660

1NO

/

1.6

0.95

16

MB2SD-D65
new

18.5/25

30/40

37/50

75

65

42

80

660

1NO+1NC

/

1.6

0.95

16

MB2SD-D80
new

22/30

37/50

45/60

90

80

50

110

660

1NO+1NC

/

1.6

0.95

16

MB2SD-D95
new

25/35

45/60

45/60

110

95

65

130

660

1NO+1NC

/

1.6

0.95

Categories
Magnetic AC Contactor

Meba contactor MB1SD09

Meba contactor MB1SD09

Meba contactor MB1SD09 Series machine interlock contactors are suitable for using in AC 50/60Hz and rating insulation voltage 690-1000V,rating voltage 380V,rating current 9A-150A under AC-3.and control the positive and negative rotation of motor. Contactors conform with IEC6094741,VDE0660 GB14048.4 and etc.

Meba contactor MB1SD09
Features:
1. Made up of by 2 same type AC contactors of LC2-D interlocked by machine interlock
2 .Machine interlock doesn’t affect the action time of AC contactor.
3. Products loops,assistant loop lead connected (the products not connected with lead supply)
4. Close frame and reliable interlock
Technical Parameter:

Type

Rated current
AC-3

Controlled power(kw)

220V

380V

415V

415V

660V

MB1SD-09

9

2.2

4

4

4

5.5

MB1SD-12

12

5.5

5.5

5.5

5.5

7.5

                  MB1SD-18

16

7.5

7.5

9

9

10

MB1SD-25

25

5.5

11

11

11

15

MB1SD-32

32

7.5

15

15

15

18.5

MB1SD-4011

40

18.5

18.5

22

22

30

MB1SD-5011

50

15

22

25

30

33

MB1SD -6511

63

18.5

30

37

37

37

MB1SD -8011

80

22

37

45

45

45

MB1SD -9511

95

22

45

45

45

41

Categories
Magnetic AC Contactor

Meba ac compressor contactor LC1-D80

Meba ac compressor contactor LC1-D80

Meba ac compressor contactor LC1-D80is mainly used in AC 50Hz(or 60Hz), rated working current up to 690V, and rated working current up to 95A in AC3 application type and used for long distance connection and breaking of circuit. Contactor can be used with suitable thermal overload relay to be combined into electro magnetic starter to protect the circuit from  risks of  possible operation overload, and is suitable in frequent start and control of AC motor. Standard: GB 14048.4, IEC60947-4-1.

Meba ac compressor contactor LC1-D80
Technical Parameter:

Coil voltage

24

32

48

110

127

220

240

380

415

440

480

660

660

50Hz

B5

C5

E5

F5

G5

M5

U5

Q5

N5

R5

T5

S5

Y5

60Hz

B6

C6

E6

F6

G6

M6

U6

Q6

N6

R6

T6

S6

Y6

50/60Hz

B7

C7

E7

F7

G7

M7

U7

Q7

N7

R7

T7

S7

Y7

Type

LC1-D09

LC1-D12

LC1-D18

LC1-D25

LC1-D32

LC1-D40

LC1-D50

LC1-D65

LC1-D80

LC1-D95

Rated insulation

660

660

660

660

660

660

660

660

660

660

Conventional thermal current

20

25

32

40

50

60

75

80

110

125

C3 Rated operational current

9

12

16

25

32

40

50

63

80

95

Controlled power(kw)

2.2

3

4

5.5

11

15

18.5

22

25

4

5.5

7.5

11

18.5

20

30

37

45

4

5.5

9

11

22

25

37

45

45

4

5.5

9

11

22

30

37

45

45

5.5

7.5

10

15

30

33

37

45

45

Note

The installation of the relays can use two screws and also use the 35mm installation rail

The installation of the relays can use three screws and also use the 75mm or 35mm installation rail

Categories
Magnetic AC Contactor

Meba contactors LC1-D40

Meba contactors LC1-D40

Meba contactors LC1-D40is mainly used in AC 50Hz(or 60Hz), rated working current up to 690V, and rated working current up to 95A in AC3 application type and used for long distance connection and breaking of circuit. Contactor can be used with suitable thermal overload relay to be combined into electro magnetic starter to protect the circuit from  risks of  possible operation overload, and is suitable in frequent start and control of AC motor. Standard: GB 14048.4, IEC60947-4-1.

Meba contactors LC1-D40
Technical Parameter:

Coil voltage

24

32

48

110

127

220

240

380

415

440

480

660

660

50Hz

B5

C5

E5

F5

G5

M5

U5

Q5

N5

R5

T5

S5

Y5

60Hz

B6

C6

E6

F6

G6

M6

U6

Q6

N6

R6

T6

S6

Y6

50/60Hz

B7

C7

E7

F7

G7

M7

U7

Q7

N7

R7

T7

S7

Y7

Type

LC1-D09

LC1-D12

LC1-D18

LC1-D25

LC1-D32

LC1-D40

LC1-D50

LC1-D65

LC1-D80

LC1-D95

Rated insulation

660

660

660

660

660

660

660

660

660

660

Conventional thermal current

20

25

32

40

50

60

75

80

110

125

C3 Rated operational current

9

12

16

25

32

40

50

63

80

95

Controlled power(kw)

2.2

3

4

5.5

11

15

18.5

22

25

4

5.5

7.5

11

18.5

20

30

37

45

4

5.5

9

11

22

25

37

45

45

4

5.5

9

11

22

30

37

45

45

5.5

7.5

10

15

30

33

37

45

45

Note

The installation of the relays can use two screws and also use the 35mm installation rail

The installation of the relays can use three screws and also use the 75mm or 35mm installation rail

Categories
Magnetic AC Contactor

Meba contactor relay LC1-D12

Meba contactor relay LC1-D12

Meba contactor relay LC1-D12, is mainly used in AC 50Hz(or 60Hz), rated working current up to 690V, and rated working current up to 95A in AC3 application type and used for long distance connection and breaking of circuit. Contactor can be used with suitable thermal overload relay to be combined into electro magnetic starter to protect the circuit from  risks of  possible operation overload, and is suitable in frequent start and control of AC motor. Standard: GB 14048.4, IEC60947-4-1.

Meba contactor relay LC1-D12
Technical Parameter:

Coil voltage

24

32

48

110

127

220

240

380

415

440

480

660

660

50Hz

B5

C5

E5

F5

G5

M5

U5

Q5

N5

R5

T5

S5

Y5

60Hz

B6

C6

E6

F6

G6

M6

U6

Q6

N6

R6

T6

S6

Y6

50/60Hz

B7

C7

E7

F7

G7

M7

U7

Q7

N7

R7

T7

S7

Y7

Type

LC1-D09

LC1-D12

LC1-D18

LC1-D25

LC1-D32

LC1-D40

LC1-D50

LC1-D65

LC1-D80

LC1-D95

Rated insulation

660

660

660

660

660

660

660

660

660

660

Conventional thermal current

20

25

32

40

50

60

75

80

110

125

C3 Rated operational current

9

12

16

25

32

40

50

63

80

95

Controlled power(kw)

2.2

3

4

5.5

11

15

18.5

22

25

4

5.5

7.5

11

18.5

20

30

37

45

4

5.5

9

11

22

25

37

45

45

4

5.5

9

11

22

30

37

45

45

5.5

7.5

10

15

30

33

37

45

45

Note

The installation of the relays can use two screws and also use the 35mm installation rail

The installation of the relays can use three screws and also use the 75mm or 35mm installation rail

Categories
Magnetic AC Contactor

Meba ac contactor relay LC1-D09

Meba ac contactor relay LC1-D09

Meba ac contactor relay LC1-D09, is mainly used in AC 50Hz(or 60Hz), rated working current up to 690V, and rated working current up to 95A in AC3 application type and used for long distance connection and breaking of circuit. Contactor can be used with suitable thermal overload relay to be combined into electro magnetic starter to protect the circuit from  risks of  possible operation overload, and is suitable in frequent start and control of AC motor. Standard: GB 14048.4, IEC60947-4-1.

Meba ac contactor relay LC1-D09
Technical Parameter:

Coil voltage

24

32

48

110

127

220

240

380

415

440

480

660

660

50Hz

B5

C5

E5

F5

G5

M5

U5

Q5

N5

R5

T5

S5

Y5

60Hz

B6

C6

E6

F6

G6

M6

U6

Q6

N6

R6

T6

S6

Y6

50/60Hz

B7

C7

E7

F7

G7

M7

U7

Q7

N7

R7

T7

S7

Y7

Type

LC1-D09

LC1-D12

LC1-D18

LC1-D25

LC1-D32

LC1-D40

LC1-D50

LC1-D65

LC1-D80

LC1-D95

Rated insulation

660

660

660

660

660

660

660

660

660

660

Conventional thermal current

20

25

32

40

50

60

75

80

110

125

C3 Rated operational current

9

12

16

25

32

40

50

63

80

95

Controlled power(kw)

2.2

3

4

5.5

11

15

18.5

22

25

4

5.5

7.5

11

18.5

20

30

37

45

4

5.5

9

11

22

25

37

45

45

4

5.5

9

11

22

30

37

45

45

5.5

7.5

10

15

30

33

37

45

45

Note

The installation of the relays can use two screws and also use the 35mm installation rail

The installation of the relays can use three screws and also use the 75mm or 35mm installation rail

Categories
Magnetic AC Contactor

Meba contactor for ac CLC1-D80

Meba contactor for ac CLC1-D80, is suitable for using in the circuits up to the rated voltage 660V AC 50Hz or 60Hz, rated current up to 620A, for making, breaking, frequently starting & controlling the AC motor. Combined with the auxiliary contact block, timer delay & machine-interlocking device etc, it becomes the delay contactor, mechanical interlocking contactor, star-delta starter. With the thermal relay, it is combined into the electromagnetic starter. The products comply with IEC60947-4.

Meba contactor for ac CLC1-D80

Technical Data
Type LC1-D09 LC1-D12 LC1-D18 LC1-D25 LC1-D32 LC1-D40 LC1-D50 LC1-D65 LC1-D80 LC1-D95
Rated working current (A) AC3 9 12 18 25 32 40 50 65 80 95
AC4 3.5 5 7.7 8.5 12 18.5 24 28 37 44
Standard power ratingsof 3-phase motors 50/60Hz in category AC-3 220/230V 2.2 3 4 5.5 7.5 11 15 18.5 22 25
380/400V 4 5.5 7.5 11 15 18.5 22 30 37 45
415V 4 5.5 9 11 15 22 25 37 45 45
500V 5.5 7.5 10 15 18.5 22 30 37 55 55
660/690V 5.5 7.5 10 15 18.5 30 33 37 45 55
Rated heat current (A) 20 20 32 40 50 60 80 80 125 125
Electrical life AC3 (x10 4 ) 100 100 100 100 80 80 60 60 60 60
AC4 (x10 4 ) 20 20 20 20 20 15 15 15 10 10
Mechanical life (x10 4 ) 1000 1000 1000 1000 800 800 800 800 600 600
Number of the contacts 3P+NO 3P+NC+NO
Categories
Magnetic AC Contactor

Meba contactor ac unit CLC1-D25

Meba contactor ac unit CLC1-D25

Meba contactor ac unit CLC1-D25 is suitable for using in the circuits up to the rated voltage 660V AC 50Hz or 60Hz, rated current up to 620A, for making, breaking, frequently starting & controlling the AC motor. Combined with the auxiliary contact block, timer delay & machine-interlocking device etc, it becomes the delay contactor, mechanical interlocking contactor, star-delta starter. With the thermal relay, it is combined into the electromagnetic starter. The products comply with IEC60947-4.

Meba contactor ac unit CLC1-D25

Technical Data
Type LC1-D09 LC1-D12 LC1-D18 LC1-D25 LC1-D32 LC1-D40 LC1-D50 LC1-D65 LC1-D80 LC1-D95
Rated working current (A) AC3 9 12 18 25 32 40 50 65 80 95
AC4 3.5 5 7.7 8.5 12 18.5 24 28 37 44
Standard power ratingsof 3-phase motors 50/60Hz in category AC-3 220/230V 2.2 3 4 5.5 7.5 11 15 18.5 22 25
380/400V 4 5.5 7.5 11 15 18.5 22 30 37 45
415V 4 5.5 9 11 15 22 25 37 45 45
500V 5.5 7.5 10 15 18.5 22 30 37 55 55
660/690V 5.5 7.5 10 15 18.5 30 33 37 45 55
Rated heat current (A) 20 20 32 40 50 60 80 80 125 125
Electrical life AC3 (x10 4 ) 100 100 100 100 80 80 60 60 60 60
AC4 (x10 4 ) 20 20 20 20 20 15 15 15 10 10
Mechanical life (x10 4 ) 1000 1000 1000 1000 800 800 800 800 600 600
Number of the contacts 3P+NO 3P+NC+NO
Categories
Magnetic AC Contactor

Meba ac contactor CLC1-D09

Meba ac contactor CLC1-D09 is suitable for using in the circuits up to the rated voltage 660V AC 50Hz or 60Hz, rated current up to 620A, for making, breaking, frequently starting & controlling the AC motor. Combined with the auxiliary contact block, timer delay & machine-interlocking device etc, it becomes the delay contactor, mechanical interlocking contactor, star-delta starter. With the thermal relay, it is combined into the electromagnetic starter. The products comply with IEC60947-4.

Meba ac contactor CLC1-D09

Technical Data
Type LC1-D09 LC1-D12 LC1-D18 LC1-D25 LC1-D32 LC1-D40 LC1-D50 LC1-D65 LC1-D80 LC1-D95
Rated working current (A) AC3 9 12 18 25 32 40 50 65 80 95
AC4 3.5 5 7.7 8.5 12 18.5 24 28 37 44
Standard power ratingsof 3-phase motors 50/60Hz in category AC-3 220/230V 2.2 3 4 5.5 7.5 11 15 18.5 22 25
380/400V 4 5.5 7.5 11 15 18.5 22 30 37 45
415V 4 5.5 9 11 15 22 25 37 45 45
500V 5.5 7.5 10 15 18.5 22 30 37 55 55
660/690V 5.5 7.5 10 15 18.5 30 33 37 45 55
Rated heat current (A) 20 20 32 40 50 60 80 80 125 125
Electrical life AC3 (x10 4 ) 100 100 100 100 80 80 60 60 60 60
AC4 (x10 4 ) 20 20 20 20 20 15 15 15 10 10
Mechanical life (x10 4 ) 1000 1000 1000 1000 800 800 800 800 600 600
Number of the contacts 3P+NO 3P+NC+NO
Categories
Magnetic AC Contactor

Meba ac contactors LC1K0910 series

Meba ac contactors LC1K0910  is used in ac circuit of 50Hz/60Hz, rated voltage up to 690V, rated current up to 12A, to connect/disconnect or other frequent control of the main circuit and ac motors. They can be conveniently connected to auxiliary contacts and proper thermal relays to protect circuit from overloading. They feature traverse double breaking points, block and zero flash over design, with multi-function combination, small volume, and reliable performance. They are perfect replacement for France TE Lc1-K, LC1-E series products, can be widely applied to magnify/switch signal in micro-electronic interface.

Meba ac contactors LC1K0910

Technical Data
 

For motor control, from 6 to 12A(AC-3)
For the control of distribution circuits, up to 20A(AC-1)
Control circuit: A. C or D. C.
And it is suitable for using in LC1-K /LC2-K /LP1-K /LP2-K.

china hot selling magnetic ac contactor lc1k

 

Outline and Mounting Dimension 

china hot selling magnetic ac contactor lc1k

Categories
Magnetic AC Contactor

Meba motor contactor 3RT1015

Meba motor contactor 3RT1015 is suitable for using in the circuits the rated voltage up to 660V AC 50Hz or 60Hz, rated current up to 620A, for making & breaking, frequently starting & controlling the AC motor. Combined with the auxiliary contact block, time delay & machine-interlocking contactor, star-delta starter. with the thermal relay, it is combined into the electromagnetic starter. The Contactor is produced according to IEC 60947-4.

Meba motor contactor 3RT1015

Technical Data
Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 Rated operational current in AC-3 up to 440V(A) Rated operational current in AC-1 up to 440V(A) Reference
230V(kW) 400V(kW) 500V(kW) 690V(kW) 1000V(kW)
2.2 3 35 4 7 18 3RT-10 15
3 4 4.5 5.5 9 22 3RT-10 16
3 5.5 5.5 5.5 12 22 3RT-10 17
3 4 4.5 4.5 9 40 3RT-10 23
3 5.5 7.5 7.5 12 40 3RT-10 24
4 7.5 10 11 17 40 3RT-10 25
5.5 11 11 11 25 40 3RT-10 26
7.5 15 18.5 18.5 32 50 3RT-10 34
11 18.5 22 22 40 60 3RT-10 35
15 22 30 22 50 55 3RT-10 36
18.5 30 37 45 30 65 100 3RT-10 44
22 37 45 55 37 80 120 3RT-10 45
22 45 55 55 37 95 120 3RT-10 46