Categories
Miniature Circuit Breaker

Meba circuit breaker fuse MBI11-100

Meba circuit breaker fuse MBI11-100,The product is suitable for power distributions and control circuits which are used in  AC50/60HZ,rated current100A and below, rated voltage is up to 400V. It can mainly used as the chief switch in the terminal combined electrical equipments as well as used for un-frequent control all kinds of small power equipments and lightings. It is suitable for mining industry, building, business, residence,etc. It is conformity with GB14048.3,IEC60947-3 standards.

1. It is composed of insulation cover, operating mechanism, contact system, etc.
2. Compact and modular design.
3. Operation reliability of the product has been greatly enhanced.

Number of Poles 1P, 2P, 3P, 4P
Rated Current (A) 32, 40,50, 63, 80, 100
Rated Voltage (V) AC 230/240, 400/415(4P)
Frequency 50/60Hz
Endurance 10000
Protection degree IP20

Meba circuit breaker fuse MBI11-100

Technical parameters:

1. No. of pole: 1p, 2p, 3p, 4p.
2. Rated current: 32A, 63A, 100A.
3. Rated voltage: 230/400V.
4. Icw: 12Ie, t=1s.
5. Rated making and breaking capacity Icm: 3Ie,1.05Ue,cosΦ=0.65.
6. Rated short-circuit making capacity Icm: 20Ie, 0.1s

Feature:

1. It is composed of insulation cover, operating mechanism, contact system, etc.
2. Compact and modularize design.
3. Operation reliability of the product has been greatly enhanced. 

Categories
Miniature Circuit Breaker

Meba b type mcb MB1316C

Meba b type mcb MB1316C, this miniature circuit breaker is used in lighting distribution system or motor distribution system for protection overload and short-circuit in the system. The product is neuteric in structure, light in weight, reliable and excellent in performance. It has high breaking capacity, can trip quickly, and its case and items are adopted by high fire-resistant and shockproof plastics. The product, with long life, is mainly used in AC 50Hz/60Hz single-pole 230V or two, three, four pole 400V circuit for overload and short-circuit protection as well as for un frequent on-and-off switching electric equipment and lighting circuit in normal case. The products comply with IEC 60898.

Meba b type mcb MB1316C

Technical parameters:

Number of Poles: 1P, 1P+N, 2P, 3P, 3P+N, 4P
Rated Current (A): 1, 2, 3, 4, 6, 10, 16, 20, 25, 32, 40, (50, 63)
Breaking Capacity (A): 6000,(4500)
Rated Voltage (V): 230/400
Rated Frequency: 50/60Hz
Endurance: ≥4000
Circumstance Temperature: -5~+40℃
Electrical Life: no less than 6000 operations
Mechanical Life: (O-C) no less than 20000 operations

Some items for your reference when selecting the device:

a)The earthing systems(TNS,TNC)

b)Short-circuit of the specific power system, which must always be less than the breaking capacity of this device

c)The rated voltage

d)Tripping curves:

  • B curve (3-5In) —- protection for people and big length cables in TN and IT systems (lights or socket circuits etc.)
  • C curve (5-10In) —- protection for resistant and inductive loads with low inrush current (groups of bulbs, motors etc)
  • D curve (10-14In) —- protection for circuits with high inrush current (transformers, double-pole motors, motors with heavy start etc)

 

Categories
Miniature Circuit Breaker

Meba breakers MBI236C

Meba breakers MBI236C , this mini circuit breaker is mainly suitable for overload and short circuit protection. It is especially used for illumination and distribution in industry and commerce.It is of pleasing outlook & high breaking capacity etc.The frame and parts adopt plastics of light weight, reliable performance, high inflammable resistance and shock resistance for long service life. It is mainly used for overload and short circuit protection within the circuit of AC 50/60Hz,rated voltage of single pole up to 230V, two, three or four pole up to 400V. It can also be used for an un-frequent switch over of the circuit and illumination under normal condition.

Meba breakers MBI236C

Technical parameters:

Rated current(A) Pole Rated voltage (V) Breaking capacity (A) Electrical life(times) Mechanical life (times)
1,2,3,4,6,10,16,20,25,32,40,50,63 1,2,3,4 1P+N 240/415 6000 8000 10000

 

Some items for your reference when selecting the device:

a)The earthing systems(TNS,TNC)

b)Short-circuit of the specific power system, which must always be less than the breaking capacity of this device

c)The rated voltage

d)Tripping curves:

  • B curve (3-5In) —- protection for people and big length cables in TN and IT systems (lights or socket circuits etc.)
  • C curve (5-10In) —- protection for resistant and inductive loads with low inrush current (groups of bulbs, motors etc)
  • D curve (10-14In) —- protection for circuits with high inrush current (transformers, double-pole motors, motors with heavy start etc)

Dimension (mm):

Hager Mini circuit breaker dimension
Meba breakers MB1236C

The over-current tripping unit protection feature:

Sequence
NO .
Release Test
current I/In
Start state Tripping
time
Expected
results
1 B,C,D 1.13In Cold state t≤1h Not tripping
2 B,C,D 1.45In Start right after
the serial NO .
1 test
t<1h Tripping
3 B,C,D 2.55In Cold state 1s<t<60s

 

Tripping
4 B
C
D
3In
5In
10In
Cold state t≤0.1s Not tripping
5 B
C
D
5In
10In
20In
Cold state t<0.1s Tripping
Categories
Miniature Circuit Breaker

Meba mcb type 1 MBDPE06

Meba mcb type 1 MBDPE06  major export to South America, Middle East market, has light weight, small size, novel structure and excellent performance. They are mounted in the metal distribution board and used in guesthouses. block of fiats, high buildings, squares, airports, railway stations, plants and enterprises etc, in AC circuits 240V(single pole)up to 415V(3poie)50Hz for protection of overload short circuit and for circuit changeover in lighting system. Breaking capacity is 3KA. The items comply with BS&NEMA STANDARD.

Feature:

MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current (Type C), 3 to 5 times rated current ( Type B ), 10 to 20 times rated current ( Type D )

BIMETAL: ensures the breaker trip when overloaded.

ARC CHAMBER: effectively dissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit.

Meba mcb type 1 MBDPE06

Technical parameters

ropicalization Relative Humidity 93% RH at 25℃
Room Temperature 10℃ a 60℃
Electrical Properties Rated at 40℃ A 6/10/15/20/30/40/50/63
Rated operating voltage at 40℃ Vac 120/240/415
Nominal Frequency Hz 50/60
Interrupting Capacity at 230V kA 3
Operating temperature -5℃ a +40℃
Degree of Protection IP20
Number of poles 1,2,3,4
Conductor cross section (minimum allowable) mm2 25
Minimum number of power moves 4000
Minimum number of mechanical operations 6000
Operation curve B/C/D
Current Trip Curve A Type B 3a 5 In
Type C 5 a 10 In
Type D 10 a 14 In
Characteristic Intervention attach
Type Of Assembly NEMA Type
Features MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current (Type C), 10 to 14 times rated current ( Type D )
BIMETAL: ensures the breaker trip when overloaded.
ARC CHAMBER: effectively dissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit.
Categories
Miniature Circuit Breaker

Meba mcb rccb GN type

Meba mcb rccb GN type  major export to South America, Middle East market, has light weight, small size, novel structure and excellent performance. They are mounted in the metal distribution board and used in guesthouses. block of fiats, high buildings, squares, airports, railway stations, plants and enterprises etc, in AC circuits 240V(single pole)up to 415V(3poie)50Hz for protection of overload short circuit and for circuit changeover in lighting system. Breaking capacity is 3KA. The items comply with BS&NEMA STANDARD.

Feature:

MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current (Type C), 3 to 5 times rated current ( Type B ), 10 to 20 times rated current ( Type D )

BIMETAL: ensures the breaker trip when overloaded.

ARC CHAMBER: effectively dissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit.

Meba mcb rccb GN type

Technical parameters

ropicalization Relative Humidity 93% RH at 25
Room Temperature 10 a 60
Electrical Properties Rated at 40 A 6/10/15/20/30/40/50/63
Rated operating voltage at 40 Vac 120/240/415
Nominal Frequency Hz 50/60
Interrupting Capacity at 230V kA 3
Operating temperature -5 a +40
Degree of Protection IP20
Number of poles 1,2,3,4
Conductor cross section (minimum allowable) mm2 25
Minimum number of power moves 4000
Minimum number of mechanical operations 6000
Operation curve B/C/D
Current Trip Curve A Type B 3a 5 In
Type C 5 a 10 In
Type D 10 a 14 In
Characteristic Intervention attach
Type Of Assembly NEMA Type
Features MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current (Type C), 10 to 14 times rated current ( Type D )
BIMETAL: ensures the breaker trip when overloaded.
ARC CHAMBER: effectively dissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit.
Categories
Miniature Circuit Breaker

Meba mcb rating MB50

Meba mcb rating MB50 major export to South America, Middle East market, has light weight, small size, novel structure and excellent performance. They are mounted in the metal distribution board and used in guesthouses. block of fiats, high buildings, squares, airports, railway stations, plants and enterprises etc, in AC circuits 240V(single pole)up to 415V(3poie)50Hz for protection of overload short circuit and for circuit changeover in lighting system. Breaking capacity is 3KA. The items comply with BS&NEMA STANDARD.

Feature:

MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current (Type C), 3 to 5 times rated current ( Type B ), 10 to 20 times rated current ( Type D )

BIMETAL: ensures the breaker trip when overloaded.

ARC CHAMBER: effectively dissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit.

Meba mcb rating MB50

Technical parameters

ropicalization Relative Humidity 93% RH at 25℃
Room Temperature 10℃ a 60℃
Electrical Properties Rated at 40℃ A 6/10/15/20/30/40/50/63
Rated operating voltage at 40℃ Vac 120/240/415
Nominal Frequency Hz 50/60
Interrupting Capacity at 230V kA 3
Operating temperature -5℃ a +40℃
Degree of Protection IP20
Number of poles 1,2,3,4
Conductor cross section (minimum allowable) mm2 25
Minimum number of power moves 4000
Minimum number of mechanical operations 6000
Operation curve B/C/D
Current Trip Curve A Type B 3a 5 In
Type C 5 a 10 In
Type D 10 a 14 In
Characteristic Intervention attach
Type Of Assembly NEMA Type
Features MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current (Type C), 10 to 14 times rated current ( Type D )
BIMETAL: ensures the breaker trip when overloaded.
ARC CHAMBER: effectively dissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit.
Categories
Miniature Circuit Breaker

Meba mcb mccb difference C65N

Meba mcb mccb difference C65N  major export to South America, Middle East market, has light weight, small size, novel structure and excellent performance. They are mounted in the metal distribution board and used in guesthouses. block of fiats, high buildings, squares, airports, railway stations, plants and enterprises etc, in AC circuits 240V(single pole)up to 415V(3poie)50Hz for protection of overload short circuit and for circuit changeover in lighting system. Breaking capacity is 3KA. The items comply with BS&NEMA STANDARD.

Feature:

MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current (Type C), 3 to 5 times rated current ( Type B ), 10 to 20 times rated current ( Type D )

BIMETAL: ensures the breaker trip when overloaded.

ARC CHAMBER: effectively dissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit.

Meba mcb mccb difference C65N

Technical parameters

ropicalization Relative Humidity 93% RH at 25℃
Room Temperature 10℃ a 60℃
Electrical Properties Rated at 40℃ A 6/10/15/20/30/40/50/63
Rated operating voltage at 40℃ Vac 120/240/415
Nominal Frequency Hz 50/60
Interrupting Capacity at 230V kA 3
Operating temperature -5℃a +40℃
Degree of Protection IP20
Number of poles 1,2,3,4
Conductor cross section (minimum allowable) mm2 25
Minimum number of power moves 4000
Minimum number of mechanical operations 6000
Operation curve B/C/D
Current Trip Curve A Type B 3a 5 In
Type C 5 a 10 In
Type D 10 a 14 In
Characteristic Intervention attach
Type Of Assembly NEMA Type
Features MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current (Type C), 10 to 14 times rated current ( Type D )
BIMETAL: ensures the breaker trip when overloaded.
ARC CHAMBER: effectively dissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit.
Categories
Miniature Circuit Breaker

Meba mcb MB8 type

Meba mcb MB8 type  can protect and control of circuit against overload and short circuit, in building installation-such as houses, offices, commercial complex, motor system(D curve) and industrial installation-for switching, control, protection and regulation of electrical circuits. Also in switch-gear panels, railway and marine application.Applicable to terminal and pin/fork type busbar connection,Protection against both overload and short circuit High short-circuit capacity

Feature:

MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current (Type C), 3 to 5 times rated current ( Type B ), 10 to 20 times rated current ( Type D )

BIMETAL: ensures the breaker trip when overloaded.

ARC CHAMBER: effectively dissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit.

Meba mcb MB8 type

Technical parameters

Tropicalization Relative Humidity 93% RH at 25℃
Room Temperature 10℃ a 60℃
Electrical Properties Rated at 40℃ A 6/10/16/20/25/32/40/50/63
Rated operating voltage at 40℃ Vac 240/415
Nominal Frequency Hz 50/60
Interrupting Capacity at 230V kA 6
Operating temperature 40
Degree of Protection IP20
Number of poles 1/2/3/4
Conductor cross section (minimum allowable) mm2 25
Minimum number of power moves 4000
Minimum number of mechanical operations 10000
Operation curve B/C/D
Current Trip Curve A 5 a 10 In
Characteristic Intervention attach
Type Of Assembly FOR RIEL DIN 35 mm
Features MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current (Type C), 3 to 5 times rated current ( Type B ), 10 to 20 times rated current ( Type D )
BIMETAL: ensures the breaker trip when overloaded.
ARC CHAMBER: effectively dissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit.
Categories
Miniature Circuit Breaker

Meba mcb in electrical MB48 type

Meba mcb in electrical MB48 type  can protect and control of circuit against overload and short circuit, in building installation-such as houses, offices, commercial complex, motor system(D curve) and industrial installation-for switching, control, protection and regulation of electrical circuits. Also in switch-gear panels, railway and marine application.Applicable to terminal and pin/fork type busbar connection,Protection against both overload and short circuit High short-circuit capacity

Meba mcb in electrical MB48 type

Technical parameters

Tropicalization Relative Humidity 93% RH at 25
Room Temperature 10 a 60
Electrical Properties Rated at 40 A 6/10/16/20/25/32/40/50/63
Rated operating voltage at 40 Vac 240/415
Nominal Frequency Hz 50/60
Interrupting Capacity at 230V kA 6
Operating temperature 40
Degree of Protection IP20
Number of poles 1/2/3/4
Conductor cross section (minimum allowable) mm2 25
Minimum number of power moves 4000
Minimum number of mechanical operations 10000
Operation curve B/C/D
Current Trip Curve A 5 a 10 In
Characteristic Intervention attach
Type Of Assembly FOR RIEL DIN 35 mm
Features MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current (Type C), 3 to 5 times rated current ( Type B ), 10 to 20 times rated current ( Type D )
BIMETAL: ensures the breaker trip when overloaded.
ARC CHAMBER: effectively dissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit.
Categories
Miniature Circuit Breaker

Meba mcb circuit breaker MBLPN2

Meba mcb circuit breaker MBLPN2  can protect and control of circuit against overload and short circuit, in building installation-such as houses, offices, commercial complex, motor system(D curve) and industrial installation-for switching, control, protection and regulation of electrical circuits. Also in switch-gear panels, railway and marine application.Applicable to terminal and pin/fork type busbar connection,Protection against both overload and short circuit High short-circuit capacity

Meba mcb circuit breaker MBLPN2

Technical parameters

Tropicalization Relative Humidity 93% RH at 25
50% RH at 40
Room Temperature -5 a 40
Electrical Properties Rated at 40 A 6/10/16/20/25/32/40/50/63
Rated operating voltage at 40 Vac 240/415
Nominal Frequency Hz 50/60
Interrupting Capacity at 230V kA 6
Operating temperature 40
Degree of Protection IP20
Number of poles 1/2/3/4
Conductor cross section (minimum allowable) mm2 25
Minimum number of power moves 4000
Minimum number of mechanical operations 8000
Operation curve B/C/D
Current Trip Curve A Type B: 3 a 5 In
Type C: 5 a 10 In
Type D: 10 a 14 In
Characteristic Intervention attach
Type Of Assembly FOR RIEL DIN 35 mm
Categories
Miniature Circuit Breaker

Meba mcb breaker MB47 type

Meba mcb breaker MB47 type series miniature circuit breaker applies to industrial, commercial, lighting and electric machine distribution system with AC415V, 50/60Hz, rated working current up to 100A to protect against overload and short circuit. The item is installed into plug-in type mounting base. It’s conformity with GB10963, IEC60898 standards.

Meba mcb breaker MB47 type

Technical parameters

Tropicalization Relative Humidity 93% RH at 25
50% RH at 40
Room Temperature -5 a 40
Electrical Properties Rated at 40 A 6/10/16/20/25/32/40/50/63
Rated operating voltage at 40 Vac 240/415
Nominal Frequency Hz 50/60
Interrupting Capacity at 230V kA 6
Operating temperature 40
Degree of Protection IP20
Number of poles 1/2/3/4
Conductor cross section (minimum allowable) mm2 25
Minimum number of power moves 4000
Minimum number of mechanical operations 8000
Operation curve B/C/D
Current Trip Curve A Type B: 3 a 5 In
Type C: 5 a 10 In
Type D: 10 a 14 In
Characteristic Intervention attach
Type Of Assembly FOR RIEL DIN 35 mm
Features MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current (Type C), 3 to 5 times rated current ( Type B ), 10 to 14 times rated current ( Type D )
BIMETAL: ensures the breaker trip when overloaded.
ARC CHAMBER: effectively dissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit.
Present Certificates CE CB
ISO 9001-2000 awarded by the competent certification body, Meba is qualified in the manufacturing of the object
IEC 60898 standards in the manufacture of the goods
Curve compliance issued Shot by an accredited laboratory for effect

 

Categories
Miniature Circuit Breaker

Meba mcb breaker DPN MB32

  • applies to industrial, commercial, lighting and electric machine distribution system
  • protect against overload and short circuit
  • AC415V, 50/60Hz, rated working current up to 100A
  • The item is installed into plug-in type mounting base
  • It’s conformity with GB10963, IEC60898 standards.

Meba mcb breaker DPN MB32

Tropicalization Relative Humidity 93% RH at 25
Room Temperature 10 a 60
Electrical Properties Rated at 40 A 6/10/16/20/25/32/40
Rated operating voltage at 40 Vac 240/415
Nominal Frequency Hz 50/60
Interrupting Capacity at 230 V kA 4.5
Operating temperature 40
Degree of Protection IP20
Number of poles 1P+N
Conductor cross section (minimum allowable) mm2 25
Minimum number of power moves 5000
Minimum number of mechanical operations 10000
Operation curve C
Current Trip Curve A 5 a 10 In
Characteristic Intervention attach
Type Of Assembly FOR RIEL DIN 35 mm
Features MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current (Type C).
BIMETAL: ensures the breaker trip when overloaded.
ARC CHAMBER: effectively dissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit.

 

Categories
Fuse Modular Devices

Meba electric fuse MBQF

Meba electric fuse MBQF

– Branch circuit protection
– Telecom power distribution
– Power conditioning
– Automatic control systems
– Power supplies
– Power conversion systems
– UPS equipment
– Control machines
– Generator sets

Meba electric fuse MBQF

Technical Data

Max. AC Voltage 230/400 VAC
Max. Interrupting Capacity 5kA rms
Min. Current Rating 0.5A
Max. Current Rating 1=125A
3=100A
Agency Recognition of Approvals IEC 60947-2
SANS VC8036
SANS 156
QF Range
Special Supply Authority/Industrial Circuit Breaker-5KA
Type Poles Voltage KA MCB Width(mm) STD Pack Rating(A)
QF-1(13) 1 230VAC 5 13 (1 Module) 12 10 15 20 25
QF-3(13) 3 400VAC 5 39 (3 Module) 4 10 15 20 25
QF-1(19) 1 230VAC 5 19.5 (1 Module) 12 10 15 20 25 30 35 40 45 50 63
QF-3(19) 3 400VAC 5 58.5 (3 Module) 4 10 15 20 25 30 35 40 45 50 63
QF-1(26) 1 230VAC 5 26 (2 Module) 12 10 15 20 25 32 40 45 50 63 70 80 100 125
QF-3(26) 3 400VAC 5 78 (3 Module) 4 10 15 20 25 32 40 45 50 63 70 80 100
Switch Disconnectors 6KA, mini and DIN Rail Mounting, 45 mm Escutcheon
Type Poles Voltage KA MCB Width(mm) STD Pack Rating(A)
QF-1(13)-D 1 230VAC 6 13 (1 Module) 12 10 15 20 25
QF-3(13)-D 3 415VAC 6 39 (3 Module) 4 10 15 20 25
QF-1(18)-D 1 240VAC 6 18 (1 Module) 12 10 15 20 25 30 35 40 45 50 63
QF-3(18)-D 3 415VAC 6 54 (3 Module) 4 10 15 20 25 30 35 40 45 50 63
QF-1(26)-D 1 240VAC 5 26 (2 Module) 12 10 15 20 25 32 40 45 50 63 70 80 100 125
QF-3(26)-D 3 415VAC 5 78 (3 Module) 4 10 15 20 25 32 40 45 50 63 70 80 100

Categories
Miniature Circuit Breaker

Meba isolator circuit breaker MB162

Meba isolator circuit breaker MB162-1P is mainly used in AC50/60Hz single pole 230V or two, three, four pole 400V voltage for overload and short-circuit protection as well as for un-frequent on-and-off switching electric equipment and lighting circuit under normal condition, the product is suitable for industry, business, building, residence, etc. It’s conformity with GB10963, IEC60898 standards.

Meba isolator circuit breaker MB162-1P

Standard IEC60898
Number of poles 1P, 2P, 3P, 4P
Rated current(In) 6, 10, 16, 20, 25, 32, 40, 50, 63
Rated voltage(Un) AC240/415V
Rated frequency 50/60Hz
Tripping curve B, C, D
Release action characteristics Time delay 1.13In>1h Non-trip
1.45In<1h trip
2.55In 1s-60S trip
Instantaneous(Curve C) 5In>0.1s Non-trip
10In<0.1s trip
Magnetic releases operate B curve:between 3 and 5In
C curve:between 5 and 10In
D curve:between 10 and 15In
Rated breaking capacity (Lcn) 3000A
Endurance >2500
Circumstance temperature -5 to +40℃
Electrical life >6000times
Mechanical life 20000 times
Tropical ration Treatment 2(RH95%, at 55℃)
Protection degree IP20

 

[Download not found]
Categories
Miniature Circuit Breaker

Meba insulator circuit breaker MBS

Meba insulator circuit breaker MBS is mainly used in AC50/60Hz single pole 230V or two, three, four pole 400V voltage for overload and short-circuit protection as well as for un-frequent on-and-off switching electric equipment and lighting circuit under normal condition, the product is suitable for industry, business, building, residence, etc. It’s conformity with GB10963, IEC60898 standards.

Meba insulator circuit breaker MBS

Standard IEC60898
Number of poles 1P, 2P, 3P, 4P
Rated current(In) 6, 10, 16, 20, 25, 32, 40, 50, 63
Rated voltage(Un) AC240/415V
Rated frequency 50/60Hz
Tripping curve B, C, D
Release action characteristics Time delay 1.13In>1h Non-trip
1.45In<1h trip
2.55In 1s-60S trip
Instantaneous(Curve C) 5In>0.1s Non-trip
10In<0.1s trip
Magnetic releases operate B curve:between 3 and 5In
C curve:between 5 and 10In
D curve:between 10 and 15In
Rated breaking capacity (Lcn) 3000A
Endurance >2500
Circumstance temperature -5 to +40℃
Electrical life >6000times
Mechanical life 20000 times
Tropical ration Treatment 2(RH95%, at 55℃)
Protection degree IP20
Categories
Miniature Circuit Breaker

Meba electric fuse MBP41

 is used in the single phase residual current of AC50/60Hz, rated voltage 220V or below for protecting electron circuit from overload and short circuit This product has advantages of high breaking capacity, small volume, width is only 18mm. Zero and live wire are cut off at the same time, preventing the person and fire danger. It is the ideal  distribution protective switch in the civil residence field at present. This product conforms to the requirement of IEC60898.

Meba electric fuse MBP41

 

. Pole No.: 1P,2P,3P,4P
. Rated voltage: AC 230V
. Rated current (A): 63A, 80A,100A
. Tripping curve: C, D
. Rated short-circuit capacity(Icn): 4000A
. Rated frequency: 50/60Hz
. Energy limiting class: 3
.  Current Trip Curve: Type C: 5 a 10 In, Type D: 10 a 14 In

Features:

MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current (Type C), 10 to 14 times rated current (Type D)

BIMETAL: ensures the breaker trip when overloaded.

ARC CHAMBER: effectively dissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit.

Categories
Miniature Circuit Breaker

Meba circuit breaker MBLSN

Meba circuit breaker MBLSN

is mainly used in AC50/60HZ single-pole 230V or two, three, four-pole 400V circuit for overload and short-circuit protection as well as for unfrequent on-and-off switching electric equipment and lighting circuit under normal condition. The product is suitable for industry, business, building, residence, etc. It is conformity with GB10963,IEC60898 standards.

MEBA Circuit Breaker MBLSN

Feature
1. Much higher short circuit breaking capacity.
2. Dual-connection convenient for both standard busbar and conductor connection.
3. Improved safety of operators offered by special design of terminals.
4. Much longer service life thanks to energy storage operating mechanism.
5. A variety of modular auxiliaries allows for easy and quick installation.
6. Enclosure and functional parts made of advanced plastics with flame-retardant,heat-resistant and impulse-proof properties.
7. Higher current-limiting capacity ensuring a cost-effective range of products.

Technical Data
– Rated current: 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A,40A,50A,63A.
– Tripping characteristics: B(3-5)In; C(5-10)In; D(10-15)In.
– No. of pole: 1p, 2p, 3p, 4p.
– Breaking capacity (see table1).

Rated current(A) Pole Rated Voltage(V) Rated short-circuit breaking current (A) COS
1~63 1 230,230/400 6000 0.7
2,3,4 400 6000 0.7
Categories
Miniature Circuit Breaker

Meba B type MCB MBB8-63-4P

Meba B type mcb MBB8-63-4P

is mainly used in AC50/60HZ single-pole 230V or two, three, four-pole 400V circuit for overload and short-circuit protection as well as for unfrequent on-and-off switching electric equipment and lighting circuit under normal condition. The product is suitable for industry, business, building, residence, etc. It is conformity with GB10963,IEC60898 standards.

Meba B type mcb MBB8-63-4P

Feature
1. Much higher short circuit breaking capacity.
2. Dual-connection convenient for both standard busbar and conductor connection.
3. Improved safety of operators offered by special design of terminals.
4. Much longer service life thanks to energy storage operating mechanism.
5. A variety of modular auxiliaries allows for easy and quick installation.
6. Enclosure and functional parts made of advanced plastics with flame-retardant,heat-resistant and impulse-proof properties.
7. Higher current-limiting capacity ensuring a cost-effective range of products.

Technical Data
– Rated current: 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A,40A,50A,63A.
– Tripping characteristics: B(3-5)In; C(5-10)In; D(10-15)In.
– No. of pole: 1p, 2p, 3p, 4p.
– Breaking capacity (see table1).

Rated current(A) Pole Rated Voltage(V) Rated short-circuit breaking current (A) COS
1~63 1 230,230/400 6000 0.7
2,3,4 400 6000 0.7
Categories
Miniature Circuit Breaker

Meba B type mcb MBB8-63-3P

Meba B type mcb MBB8-63-3P

is mainly used in AC50/60HZ single-pole 230V or two, three, four-pole 400V circuit for overload and short-circuit protection as well as for unfrequent on-and-off switching electric equipment and lighting circuit under normal condition. The product is suitable for industry, business, building, residence, etc. It is conformity with GB10963,IEC60898 standards.

Meba B type mcb MBB8-63-3P

Feature
1. Much higher short circuit breaking capacity.
2. Dual-connection convenient for both standard busbar and conductor connection.
3. Improved safety of operators offered by special design of terminals.
4. Much longer service life thanks to energy storage operating mechanism.
5. A variety of modular auxiliaries allows for easy and quick installation.
6. Enclosure and functional parts made of advanced plastics with flame-retardant,heat-resistant and impulse-proof properties.
7. Higher current-limiting capacity ensuring a cost-effective range of products.

Technical Data
– Rated current: 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A,40A,50A,63A.
– Tripping characteristics: B(3-5)In; C(5-10)In; D(10-15)In.
– No. of pole: 1p, 2p, 3p, 4p.
– Breaking capacity (see table1).

Rated current(A) Pole Rated Voltage(V) Rated short-circuit breaking current (A) COS
1~63 1 230,230/400 6000 0.7
2,3,4 400 6000 0.7
Categories
Miniature Circuit Breaker

Meba B type mcb MBB8-63

Meba b type breaker MBB8-63

Meba b type breaker MBB8-63

MCB is mainly used in AC50/60HZ single-pole 230V or two, three, four-pole 400V circuit for overload and short-circuit protection as well as for unfrequent on-and-off switching electric equipment and lighting circuit under normal condition. The product is suitable for industry, business, building, residence, etc. It is conformity with GB10963,IEC60898 standards.

Meba b type breaker MBB8-63

Feature
1. Much higher short circuit breaking capacity.
2. Dual-connection convenient for both standard busbar and conductor connection.
3. Improved safety of operators offered by special design of terminals.
4. Much longer service life thanks to energy storage operating mechanism.
5. A variety of modular auxiliaries allows for easy and quick installation.
6. Enclosure and functional parts made of advanced plastics with flame-retardant,heat-resistant and impulse-proof properties.
7. Higher current-limiting capacity ensuring a cost-effective range of products.

Technical Data
– Rated current: 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A,40A,50A,63A.
– Tripping characteristics: B(3-5)In; C(5-10)In; D(10-15)In.
– No. of pole: 1p, 2p, 3p, 4p.
– Breaking capacity (see table1).

Rated current(A) Pole Rated Voltage(V) Rated short-circuit breaking current (A) COS
1~63 1 230,230/400 6000 0.7
2,3,4 400 6000 0.7