Categories
Residual Current Circuit Breaker

Meba Residual Current Device Operation OLL2-4P

Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: OLL2
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 4P

Application:

1. OLL2, Residual Current Devices for earth leakage detection.

2. It is to be used in association with miniature circuit breakers, its function is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.

3. These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.

Merits:

Good quality , high breaking capability, updated structure,quick trip and guide installation, competitive price,excellent and safe performance,beautiful and compact appearance, etc .

Mounting Requirements:

1. Circumstance temperature -5°C ~ +40°C, average temperature not exceeding 35°C.
2. Altitude above sea level less than 2000 m.
3. Humidity not exceeding 50% at 40°C and not exceeding 90% at 25°C.
4. Installation class II or III.
5. Pollution class 2.
6. Installation method DIN Rail mounting type.
7. The external magnetism shall not be more than 5 times of terrestrial one.
8. Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position.

1. Electromagnetic and Electronic type
2. 70mm wide for 2 pole Din Rail installation.
3. Standsrd: IEC1008/EN61008
4. Rated Voltage(Un): 2pole, 230V AC
5. Rated Current(In): 25, 40, 63A
6. Rated residual operating current(I△n): 30, 100, 300, 500mA
7. Rated residual non-operating current(I△no): 0.5 I△n
8. Residual current off-time: ≤0.1s
9. Minimum value of rated breaking capacity(lm): 630A
10. Rated conditional short-circuit capacity (lnc): 6KA

[Download not found]Meba Residual Current Device Operation OLL2-4P open a circuit automatically in the event of an earth fault between phase and earth and/or netural and earth.

Categories
Residual Current Circuit Breaker

Meba Residual Current Operated Circuit Breakers OLL2-2P

Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: OLL2
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 4P

Application:

1. OLL2, Residual Current Devices for earth leakage detection.

2. It is to be used in association with miniature circuit breakers, its function is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.

3. These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.

Merits:

Good quality , high breaking capability, updated structure,quick trip and guide installation, competitive price,excellent and safe performance,beautiful and compact appearance, etc .

Mounting Requirements:

1. Circumstance temperature -5°C ~ +40°C, average temperature not exceeding 35°C.
2. Altitude above sea level less than 2000 m.
3. Humidity not exceeding 50% at 40°C and not exceeding 90% at 25°C.
4. Installation class II or III.
5. Pollution class 2.
6. Installation method DIN Rail mounting type.
7. The external magnetism shall not be more than 5 times of terrestrial one.
8. Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position.

1. Electromagnetic and Electronic type
2. 35mm wide for 2 pole Din Rail installation.
3. Standsrd: IEC1008/EN61008
4. Rated Voltage(Un): 2pole, 230V AC
5. Rated Current(In): 25, 40, 63A
6. Rated residual operating current(I△n): 30, 100, 300, 500mA
7. Rated residual non-operating current(I△no): 0.5 I△n
8. Residual current off-time: ≤0.1s
9. Minimum value of rated breaking capacity(lm): 630A
10. Rated conditional short-circuit capacity (lnc): 6KA

[Download not found]Meba Residual Current Operated Circuit Breakers OLL2-2P open a circuit automatically in the event of an earth fault between phase and earth and/or netural and earth.

Categories
Residual Current Circuit Breaker

Meba New ID ELCB Earth Leakage Device MNL-2P

Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: MNL
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 2P

Application:

1. MNL 2P, Residual Current Devices for earth leakage detection.

2. It is to be used in association with miniature circuit breakers, its function is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.

3. These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.

Merits:

Good quality , high breaking capability, updated structure,quick trip and guide installation, competitive price,excellent and safe performance,beautiful and compact appearance, etc .

Mounting Requirements:

1. Circumstance temperature -5°C ~ +40°C, average temperature not exceeding 35°C.
2. Altitude above sea level less than 2000 m.
3. Humidity not exceeding 50% at 40°C and not exceeding 90% at 25°C.
4. Installation class II or III.
5. Pollution class 2.
6. Installation method DIN Rail mounting type.
7. The external magnetism shall not be more than 5 times of terrestrial one.
8. Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position.

1. Electromagnetic and Electronic type
2. 35mm wide for 2 pole Din Rail installation.
3. Standsrd: IEC1008/EN61008
4. Rated Voltage(Un): 2pole, 230V AC
5. Rated Current(In): 25, 40, 63A
6. Rated residual operating current(I△n): 30, 100, 300, 500mA
7. Rated residual non-operating current(I△no): 0.5 I△n
8. Residual current off-time: ≤0.1s
9. Minimum value of rated breaking capacity(lm): 630A
10. Rated conditional short-circuit capacity (lnc): 6KA

[Download not found]Meba New ID ELCB Earth Leakage Device MNL-2P open a circuit automatically in the event of an earth fault between phase and earth and/or netural and earth.

Categories
Residual Current Circuit Breaker

Meba Residual Current Device Operation MBEFI 2P

1. Residual current circuit breakers MBEFI are used for protection against indirect touching of parts under voltage.

2. For prevention of lasting voltage on earthed parts which should appear because of a defect in the electrical installation and for protection against direct contacts of parts under voltage in case of I n 30mA.

3. Residual current circuit breakers can be used in TN-S, TN-C, TT and IT network systems or with other words in all systems where neutral and protective conductor are separated (VDE 0100 Teil 410).

4. Types – Our programme comprises residual current circuit breakers which are sensitive to alternating residu al current (AC-type) and residual current circuit breakers which are sensitive to alternating and pulsating direct current (A-type).

Merits:

Good quality , high breaking capability, updated structure,quick trip and guide installation, competitive price,excellent and safe performance,beautiful and compact appearance, etc .

MBEFI2 MBEFI4
type A type AC type G type A type AC type S type G
For alternating residual current
For alternating and pulsating direct residual current
Short-circuit capacity with back-up fuse
VDE 0664, part 1(up to 80A)
lower temperature limit of application -25℃
Selective (time delayed min. 40 ms)
Short time delayed (min. 10 ms)

MBEFI-2 type A, MBEFI-2 type AC

In [A] IΔn [A] number of poles code No.A code No.AC weight [g] packaging [pcs]
16 0,03 2 002062521 002062121 229 1/54
25 0,03 2 002062522 002062122 229 1/54
40 0,03 2 002062523 002062123 229 1/54
63 0,03 2 002062524 002062124 244 1/54
80 0,03 2 002062525 002062125 244 1/54
100 0,03 2 002062126 244 1/54
16 0,1 2 002063521 002063121 223 1/54
25 0,1 2 002063522 002063122 223 1/54
40 0,1 2 002063523 002063123 223 1/54
63 0,1 2 002063524 002063124 227 1/54
80 0,1 2 002063525 002063125 230 1/54
100 0,1 2 002063526 230 1/54
16 0,3 2 002064521 002064121 223 1/54
25 0,3 2 002064522 002064122 223 1/54
40 0,3 2 002064523 002064123 223 1/54
63 0,3 2 002064524 002064124 227 1/54
80 0,3 2 002064525 002064125 230 1/54
100 0,3 2 002064526 002064126 230 1/54
16 0.5 2 002065521 002065121 223 1/54
25 0,5 2 002065522 002065122 223 1/54
40 0,5 2 002065523 002065123 223 1/54
63 0,5 2 002065524 002065124 227 1/54
80 0,5 2 002065525 002065125 230 1/54

MBEFI-2 type G

In [A] IΔn [A] number of poles code No.AC weight [g] packaging [pcs]
25 0,03 2 002062722* 220 1/54
25 0,1 2 002063722* 220 1/54
40 0,3 2 002062723* 220 1/54
40 0,1 2 002063723* 220 1/54

*The same housing as MBEFI-2 100 A.

[Download not found]Meba Residual Current Device Operation MBEFI 2P a wide range of current ratings and sensitivities are available. Suitable for domestic, commercial and industrial applications.