Categories
C Series Moulded Case Circuit Breaker

Meba Electrical Mccb E2FM 225

·Brief description
1. Compared with traditional circuit breaker or relevant fuse,MEBA C series circuit breaker has excellent protection performance in smaller space, in maximum range can satisfy rated current and faulty current’s requirement.
2. C series  circuit breaker  can  be used in cascade system,  meet next stage circuit breaker’s limit section capacity select protection req-uirement, save whole system cost.
C series circuit breaker complies with IECZ60947-2 international standard;  also comply with main industrial countries standard.

·Features
1. C series  circuit  breaker  including 7 basic frames, frame current from  100  to  2500A.  Each  frame  has up to  415V 100KA (AC240V 200KA)short circuit breaking capacity multiple choice, more flexibility in design, and save space as well.
2. Actually, using  C series  circuit breaker  can  avoid  in  re-design system.  It  can be used in original  switchboard,  feeder ark, bus duct, equipment control panel,  motor  control  center  substitute of old type circuit  breaker.  At  most situations,  can  adopt  same Connector bar, terminal and shaft structure.
3. Circuit  breaker  stan dard  temperature  is  40  degree,  for other higher  ambient  temperature  situation,  can  use  50  degree  factory finalize type design circuit breaker.
4. C series circuit breaker can be used in DC situation as well, 630A frame  3P  circuit breaker   concatenation  used  in  DC600V  breaking capacity can reach 40KA.

·Most reasonable contact terminal system design
C series circuit breaker flexible and special specific is adopt one of the most reasonable design in circuit breaker history, can assure circuit breaker in high fault current fast and reliable breaking.

·Whole testing process in factory
Each C series circuit breaker steady and reliable quality is acc-ording to a whole testing procedure assurance, each circuit breaker’s same pole has to make two times setting test to verify trip,  operating characteristic and electric circuit contentiously.

·High breaking capacity in smaller space
C circuit breaker in shape and electric function can be interchan-ged with Westinghouse moulded case circuit breaker, this means C series circuit breaker is ideal product after  improve its equipment design.

·Operation structure
1.C  series  circuit breaker adopt in fast-separate  and  fast-close mechanical  operation,  which has free trip function,  assure  circuit breaker in short circuit time can not keep closed.
2. Circuit  breaker’s  trip shaft’s  position and two sides’  windows point its working condition:  ‘witch-on’, ‘reak- brake’ and ‘rip’ If circuit breaker overloading,  short circuit, shunt  or  under voltage or press TEST button makes trip, shaft will slip to ‘rip’ position. At mean while if need  circuit  breaker re-switch on,  it should switch shaft to reset position then break brake.

·Current limit feature
   C series circuit breaker adopts high repulsion contact terminal structure and advantage ARC technology, so it has significant currentlimit function.

·Standard
  IEC60947-1:General rule
IEC60947-2:Circuit breaker
IEC60947-3:Switch, isolating switch, load switch etc.

C Series Trip unit type work

E2FM 225 Parameter

Working condition:
1.The altitude not exceeding 2000m
2.The ambient temperature is from +40°Cto -5°C
3.Ambient environment is free from explosive danger and air or dust, which may cause corrosion of metal or weakness of insulation.
4.Ambient environment is free from erosion of rain or snow.
5.Pollution degree 3
6.Over-voltage category III

C series MCCB Structure

 [Download not found]Meba Electrical Mccb E2FM 225 is big ampere circuit breaker  with high breaking capacity match with RCCB, MCB  use  to protection power distribution equipment safety.

Categories
Air Circuit Breaker

Meba Air Circuit Breakers KW 400S

·Brief description
1. Compared with traditional circuit breaker or relevant fuse,MEBA C series circuit breaker has excellent protection performance in smaller space, in maximum range can satisfy rated current and faulty current’s requirement.
2. C series  circuit breaker  can  be used in cascade system,  meet next stage circuit breaker’s limit section capacity select protection req-uirement, save whole system cost.
C series circuit breaker complies with IECZ60947-2 international standard;  also comply with main industrial countries standard.

·Features
1. C series  circuit  breaker  including 7 basic frames, frame current from  100  to  2500A.  Each  frame  has up to  415V 100KA (AC240V 200KA)short circuit breaking capacity multiple choice, more flexibility in design, and save space as well.
2. Actually, using  C series  circuit breaker  can  avoid  in  re-design system.  It  can be used in original  switchboard,  feeder ark, bus duct, equipment control panel,  motor  control  center  substitute of old type circuit  breaker.  At  most situations,  can  adopt  same Connector bar, terminal and shaft structure.
3. Circuit  breaker  stan dard  temperature  is  40  degree,  for other higher  ambient  temperature  situation,  can  use  50  degree  factory finalize type design circuit breaker.
4. C series circuit breaker can be used in DC situation as well, 630A frame  3P  circuit breaker   concatenation  used  in  DC600V  breaking capacity can reach 40KA.

·Most reasonable contact terminal system design
C series circuit breaker flexible and special specific is adopt one of the most reasonable design in circuit breaker history, can assure circuit breaker in high fault current fast and reliable breaking.

·Whole testing process in factory
Each C series circuit breaker steady and reliable quality is acc-ording to a whole testing procedure assurance, each circuit breaker’s same pole has to make two times setting test to verify trip,  operating characteristic and electric circuit contentiously.

·High breaking capacity in smaller space
C circuit breaker in shape and electric function can be interchan-ged with Westinghouse moulded case circuit breaker, this means C series circuit breaker is ideal product after  improve its equipment design.

·Operation structure
1.C  series  circuit breaker adopt in fast-separate  and  fast-close mechanical  operation,  which has free trip function,  assure  circuit breaker in short circuit time can not keep closed.
2. Circuit  breaker’s  trip shaft’s  position and two sides’  windows point its working condition:  ‘witch-on’, ‘reak- brake’ and ‘rip’ If circuit breaker overloading,  short circuit, shunt  or  under voltage or press TEST button makes trip, shaft will slip to ‘rip’ position. At mean while if need  circuit  breaker re-switch on,  it should switch shaft to reset position then break brake.

·Current limit feature
   C series circuit breaker adopts high repulsion contact terminal structure and advantage ARC technology, so it has significant currentlimit function.

·Standard
  IEC60947-1:General rule
IEC60947-2:Circuit breaker
IEC60947-3:Switch, isolating switch, load switch etc.

C Series Trip unit type work

GWF 125S Parameter

Working condition:
1.The altitude not exceeding 2000m
2.The ambient temperature is from +40°Cto -5°C
3.Ambient environment is free from explosive danger and air or dust, which may cause corrosion of metal or weakness of insulation.
4.Ambient environment is free from erosion of rain or snow.
5.Pollution degree 3
6.Over-voltage category III

C series MCCB Structure

 [Download not found]Meba Air Circuit Breakers KW 400S is big ampere circuit breaker  with high breaking capacity match with RCCB, MCB  use  to protection power distribution equipment safety.

Categories
C Series Moulded Case Circuit Breaker

Meba Vacuum Circuit Breaker LW 630S

·Brief description
1. Compared with traditional circuit breaker or relevant fuse,MEBA C series circuit breaker has excellent protection performance in smaller space, in maximum range can satisfy rated current and faulty current’s requirement.
2. C series  circuit breaker  can  be used in cascade system,  meet next stage circuit breaker’s limit section capacity select protection req-uirement, save whole system cost.
C series circuit breaker complies with IECZ60947-2 international standard;  also comply with main industrial countries standard.

·Features
1. C series  circuit  breaker  including 7 basic frames, frame current from  100  to  2500A.  Each  frame  has up to  415V 100KA (AC240V 200KA)short circuit breaking capacity multiple choice, more flexibility in design, and save space as well.
2. Actually, using  C series  circuit breaker  can  avoid  in  re-design system.  It  can be used in original  switchboard,  feeder ark, bus duct, equipment control panel,  motor  control  center  substitute of old type circuit  breaker.  At  most situations,  can  adopt  same Connector bar, terminal and shaft structure.
3. Circuit  breaker  stan dard  temperature  is  40  degree,  for other higher  ambient  temperature  situation,  can  use  50  degree  factory finalize type design circuit breaker.
4. C series circuit breaker can be used in DC situation as well, 630A frame  3P  circuit breaker   concatenation  used  in  DC600V  breaking capacity can reach 40KA.

·Most reasonable contact terminal system design
C series circuit breaker flexible and special specific is adopt one of the most reasonable design in circuit breaker history, can assure circuit breaker in high fault current fast and reliable breaking.

·Whole testing process in factory
Each C series circuit breaker steady and reliable quality is acc-ording to a whole testing procedure assurance, each circuit breaker’s same pole has to make two times setting test to verify trip,  operating characteristic and electric circuit contentiously.

·High breaking capacity in smaller space
C circuit breaker in shape and electric function can be interchan-ged with Westinghouse moulded case circuit breaker, this means C series circuit breaker is ideal product after  improve its equipment design.

·Operation structure
1.C  series  circuit breaker adopt in fast-separate  and  fast-close mechanical  operation,  which has free trip function,  assure  circuit breaker in short circuit time can not keep closed.
2. Circuit  breaker’s  trip shaft’s  position and two sides’  windows point its working condition:  ‘witch-on’, ‘reak- brake’ and ‘rip’ If circuit breaker overloading,  short circuit, shunt  or  under voltage or press TEST button makes trip, shaft will slip to ‘rip’ position. At mean while if need  circuit  breaker re-switch on,  it should switch shaft to reset position then break brake.

·Current limit feature
   C series circuit breaker adopts high repulsion contact terminal structure and advantage ARC technology, so it has significant currentlimit function.

·Standard
  IEC60947-1:General rule
IEC60947-2:Circuit breaker
IEC60947-3:Switch, isolating switch, load switch etc.

C Series Trip unit type work

GWF 125S Parameter

Working condition:
1.The altitude not exceeding 2000m
2.The ambient temperature is from +40°Cto -5°C
3.Ambient environment is free from explosive danger and air or dust, which may cause corrosion of metal or weakness of insulation.
4.Ambient environment is free from erosion of rain or snow.
5.Pollution degree 3
6.Over-voltage category III

C series MCCB Structure

[Download not found]Meba Vacuum Circuit Breaker LW 630S is big ampere circuit breaker  with high breaking capacity match with RCCB, MCB  use  to protection power distribution equipment safety.

Categories
C Series Moulded Case Circuit Breaker

Meba Energy Distribution Panel Boards FWF 225S

·Brief description
1. Compared with traditional circuit breaker or relevant fuse,MEBA C series circuit breaker has excellent protection performance in smaller space, in maximum range can satisfy rated current and faulty current’s requirement.
2. C series  circuit breaker  can  be used in cascade system,  meet next stage circuit breaker’s limit section capacity select protection req-uirement, save whole system cost.
C series circuit breaker complies with IECZ60947-2 international standard;  also comply with main industrial countries standard.

·Features
1. C series  circuit  breaker  including 7 basic frames, frame current from  100  to  2500A.  Each  frame  has up to  415V 100KA (AC240V 200KA)short circuit breaking capacity multiple choice, more flexibility in design, and save space as well.
2. Actually, using  C series  circuit breaker  can  avoid  in  re-design system.  It  can be used in original  switchboard,  feeder ark, bus duct, equipment control panel,  motor  control  center  substitute of old type circuit  breaker.  At  most situations,  can  adopt  same Connector bar, terminal and shaft structure.
3. Circuit  breaker  stan dard  temperature  is  40  degree,  for other higher  ambient  temperature  situation,  can  use  50  degree  factory finalize type design circuit breaker.
4. C series circuit breaker can be used in DC situation as well, 630A frame  3P  circuit breaker   concatenation  used  in  DC600V  breaking capacity can reach 40KA.

·Most reasonable contact terminal system design
C series circuit breaker flexible and special specific is adopt one of the most reasonable design in circuit breaker history, can assure circuit breaker in high fault current fast and reliable breaking.

·Whole testing process in factory
Each C series circuit breaker steady and reliable quality is acc-ording to a whole testing procedure assurance, each circuit breaker’s same pole has to make two times setting test to verify trip,  operating characteristic and electric circuit contentiously.

·High breaking capacity in smaller space
C circuit breaker in shape and electric function can be interchan-ged with Westinghouse moulded case circuit breaker, this means C series circuit breaker is ideal product after  improve its equipment design.

·Operation structure
1.C  series  circuit breaker adopt in fast-separate  and  fast-close mechanical  operation,  which has free trip function,  assure  circuit breaker in short circuit time can not keep closed.
2. Circuit  breaker’s  trip shaft’s  position and two sides’  windows point its working condition:  ‘witch-on’, ‘reak- brake’ and ‘rip’ If circuit breaker overloading,  short circuit, shunt  or  under voltage or press TEST button makes trip, shaft will slip to ‘rip’ position. At mean while if need  circuit  breaker re-switch on,  it should switch shaft to reset position then break brake.

·Current limit feature
   C series circuit breaker adopts high repulsion contact terminal structure and advantage ARC technology, so it has significant currentlimit function.

·Standard
  IEC60947-1:General rule
IEC60947-2:Circuit breaker
IEC60947-3:Switch, isolating switch, load switch etc.

C Series Trip unit type work

GWF 125S Parameter

Working condition:
1.The altitude not exceeding 2000m
2.The ambient temperature is from +40°Cto -5°C
3.Ambient environment is free from explosive danger and air or dust, which may cause corrosion of metal or weakness of insulation.
4.Ambient environment is free from erosion of rain or snow.
5.Pollution degree 3
6.Over-voltage category III

C series MCCB Structure

[Download not found]Meba Energy Distribution Panel Boards FWF 225S is big ampere circuit breaker  with high breaking capacity match with RCCB, MCB  use  to protection power distribution equipment safety. 

Categories
C Series Moulded Case Circuit Breaker

Meba electrical mccb circuit breaker c series s type with lock GWF 125S

·Brief description
1. Compared with traditional circuit breaker or relevant fuse,MEBA C series circuit breaker has excellent protection performance in smaller space, in maximum range can satisfy rated current and faulty current’s requirement.
2. C series  circuit breaker  can  be used in cascade system,  meet next stage circuit breaker’s limit section capacity select protection req-uirement, save whole system cost.
C series circuit breaker complies with IECZ60947-2 international standard;  also comply with main industrial countries standard.

·Features
1. C series  circuit  breaker  including 7 basic frames, frame current from  100  to  2500A.  Each  frame  has up to  415V 100KA (AC240V 200KA)short circuit breaking capacity multiple choice, more flexibility in design, and save space as well.
2. Actually, using  C series  circuit breaker  can  avoid  in  re-design system.  It  can be used in original  switchboard,  feeder ark, bus duct, equipment control panel,  motor  control  center  substitute of old type circuit  breaker.  At  most situations,  can  adopt  same Connector bar, terminal and shaft structure.
3. Circuit  breaker  stan dard  temperature  is  40  degree,  for other higher  ambient  temperature  situation,  can  use  50  degree  factory finalize type design circuit breaker.
4. C series circuit breaker can be used in DC situation as well, 630A frame  3P  circuit breaker   concatenation  used  in  DC600V  breaking capacity can reach 40KA.

·Most reasonable contact terminal system design
C series circuit breaker flexible and special specific is adopt one of the most reasonable design in circuit breaker history, can assure circuit breaker in high fault current fast and reliable breaking.

·Whole testing process in factory
Each C series circuit breaker steady and reliable quality is acc-ording to a whole testing procedure assurance, each circuit breaker’s same pole has to make two times setting test to verify trip,  operating characteristic and electric circuit contentiously.

·High breaking capacity in smaller space
C circuit breaker in shape and electric function can be interchan-ged with Westinghouse moulded case circuit breaker, this means C series circuit breaker is ideal product after  improve its equipment design.

·Operation structure
1.C  series  circuit breaker adopt in fast-separate  and  fast-close mechanical  operation,  which has free trip function,  assure  circuit breaker in short circuit time can not keep closed.
2. Circuit  breaker’s  trip shaft’s  position and two sides’  windows point its working condition:  ‘witch-on’, ‘reak- brake’ and ‘rip’ If circuit breaker overloading,  short circuit, shunt  or  under voltage or press TEST button makes trip, shaft will slip to ‘rip’ position. At mean while if need  circuit  breaker re-switch on,  it should switch shaft to reset position then break brake.

·Current limit feature
   C series circuit breaker adopts high repulsion contact terminal structure and advantage ARC technology, so it has significant currentlimit function.

·Standard
  IEC60947-1:General rule
IEC60947-2:Circuit breaker
IEC60947-3:Switch, isolating switch, load switch etc.

C Series Trip unit type work

GWF 125S Parameter

Working condition:
1.The altitude not exceeding 2000m
2.The ambient temperature is from +40°Cto -5°C
3.Ambient environment is free from explosive danger and air or dust, which may cause corrosion of metal or weakness of insulation.
4.Ambient environment is free from erosion of rain or snow.
5.Pollution degree 3
6.Over-voltage category III

C series MCCB Structure

[Download not found]Meba electrical mccb circuit breaker c series s type with lock GWF125S is big ampere circuit breaker  with high breaking capacity match with RCCB, MCB  use  to protection power distribution equipment safety.

Categories
C Series Moulded Case Circuit Breaker

Meba Main Switch Gear H630h

·Brief description
1. Compared with traditional circuit breaker or relevant fuse,MEBA C series circuit breaker has excellent protection performance in smaller space, in maximum range can satisfy rated current and faulty current’s requirement.
2. C series  circuit breaker  can  be used in cascade system,  meet next stage circuit breaker’s limit section capacity select protection req-uirement, save whole system cost.
C series circuit breaker complies with IECZ60947-2 international standard;  also comply with main industrial countries standard.
·Features
1. C series  circuit  breaker  including 7 basic frames, frame current from  100  to  2500A.  Each  frame  has up to  415V 100KA (AC240V 200KA)short circuit breaking capacity multiple choice, more flexibility in design, and save space as well.
2. Actually, using  C series  circuit breaker  can  avoid  in  re-design system.  It  can be used in original  switchboard,  feeder ark, bus duct, equipment control panel,  motor  control  center  substitute of old type circuit  breaker.  At  most situations,  can  adopt  same Connector bar, terminal and shaft structure.
3. Circuit  breaker  stan dard  temperature  is  40  degree,  for other higher  ambient  temperature  situation,  can  use  50  degree  factory finalize type design circuit breaker.
4. C series circuit breaker can be used in DC situation as well, 630A frame  3P  circuit breaker   concatenation  used  in  DC600V  breaking capacity can reach 40KA.

·Most reasonable contact terminal system design
C series circuit breaker flexible and special specific is adopt one of the most reasonable design in circuit breaker history, can assure circuit breaker in high fault current fast and reliable breaking.

·Whole testing process in factory
Each C series circuit breaker steady and reliable quality is acc-ording to a whole testing procedure assurance, each circuit breaker’s same pole has to make two times setting test to verify trip,  operating characteristic and electric circuit contentiously.

·High breaking capacity in smaller space
C circuit breaker in shape and electric function can be interchan-ged with Westinghouse moulded case circuit breaker, this means C series circuit breaker is ideal product after  improve its equipment design.
·Operation structure
1.C  series  circuit breaker adopt in fast-separate  and  fast-close mechanical  operation,  which has free trip function,  assure  circuit breaker in short circuit time can not keep closed.
2. Circuit  breaker’s  trip shaft’s  position and two sides’  windows point its working condition:  ‘witch-on’, ‘reak- brake’ and ‘rip’ If circuit breaker overloading,  short circuit, shunt  or  under voltage or press TEST button makes trip, shaft will slip to ‘rip’ position. At mean while if need  circuit  breaker re-switch on,  it should switch shaft to reset position then break brake.

·Current limit feature
   C series circuit breaker adopts high repulsion contact terminal structure and advantage ARC technology, so it has significant currentlimit function.
·Standard
  IEC60947-1:General rule
IEC60947-2:Circuit breaker
IEC60947-3:Switch, isolating switch, load switch etc.

C Series Trip unit type work

H126h-Parameter

Working condition:
1.The altitude not exceeding 2000m
2.The ambient temperature is from +40°Cto -5°C
3.Ambient environment is free from explosive danger and air or dust, which may cause corrosion of metal or weakness of insulation.
4.Ambient environment is free from erosion of rain or snow.
5.Pollution degree 3
6.Over-voltage category III

C series MCCB Structure

[Download not found]Meba Main Switch Gear H630h is big ampere circuit breaker  with high breaking capacity match with RCCB, MCB  use  to protection power distribution equipment safety.

Categories
Universal Sockets

Meba uk electric socket MS-6P-2035

Meba uk electric socket MS-6P-2035

1. Shell: Aluminum alloy
2. Protection:
2. Control: Multi-function anti-lighting and anti-surge device
4. Certification: CE, RoHS
5. Export Markets: Gobal
6. Productioin Capacity: 200, 000/Year
7. Packing: Carton with PE

Meba uk electric socket MS-6P-2035

Technical Parameter:

Model No: MS 6P /2035

Rated Voltage : 250 VAC

Rated Frequency : 50/60 Hz

Rated Current: 16 A

Surrounding Temperature : -10 To + 60℃

Humidity : 60 % At + 40 C

Overload Breaking Capacity : 16 A

Standard: UL817, CSA 22.2 , CEE7 V11

Packing way: Standard export carton box

Certificate: CE

Categories
Universal Sockets

Meba power socket MS2015

Meba power socket MS2015

1. Shell: Aluminum alloy
2. Protection:
2. Control: Multi-function anti-lighting and anti-surge device
4. Certification: CE, RoHS
5. Export Markets: Gobal
6. Productioin Capacity: 200, 000/Year
7. Packing: Carton with PE

Meba power socket MS2015

Technical Parameter:

Model No: MS 6P /2015

Rated Voltage : 250 VAC

Rated Frequency : 50/60 Hz

Rated Current: 16 A

Surrounding Temperature : -10 To + 60 ℃

Humidity : 60 % At + 40 C

Overload Breaking Capacity : 16 A

Standard: UL817, CSA 22.2 , CEE7 V11

Packing way: Standard export carton box

Certificate: CE

Categories
Automatic Voltage Regulator

Meba Single Phase Desk Type Servo Motor Voltage Regulator SVC-1000W

General:

SVC single-phase and three-phase high accuracy full-automatic AC voltage stabilizer is one kind of our dominant products, made up of contact auto voltage regulator, servo motor, automatic control circuit, etc.

When the power network voltage fluctuates or the load varies, automatic sampling control circuit will send signal to drive the servo motor which can adjust the position of carbon brush of auto voltage regulator, then, the output voltage will be adjusted to rated value and get a steady state.

It has excellent features, such as elegant appearance, compact structure, light weight, small waveform distortion, high efficiency, stable and reliable performance and so on.

This product is an ideal stabilized voltage supply, widely used in any locations requiring electricity and ensures your power device can run normally.

Application:

For office equipment, test equipment, lighting systems, safety alarm systems, communication systems, medical equipment, duplicators, stereo sound equipment, industrial automatic equipment, color film developing equipment, digital control machine tools, checkout equipment, TV sets, office appliances.

Performance:

Single-phase input voltage Single phase 160V-250V
Single-phase output voltage 1. 0.5KVA~3KVA: Single -phase 220V and 110V
2. 5KVA~30KVA: Single -phase 220V
Three-phase input voltage 1. Phase voltage 160-250V
2. Wire voltage 227-430V
Three-phase output voltage 1. Phase voltage 220V
2. Wire voltage 380V
Voltage stabilizing precision 220V±3% 110V±6%
Frequency 50Hz/60Hz
Adjustable time <1s(when input voltage has a change of 10%)
Efficiency >90%
Over-voltage protection 246V±4V
Delay time Long 5min±2min, short 5s±2s
Ambient temperature -5℃ ~ +40℃
Relative humidity ≤90%
Waveform distortion No additional waveform distortion
Load power factor 0.8
Dielectric strength 1500V/1min
lnsulation resistance ≥2MΩ

 

Model and Sepc:

Spec(VA) Product size DXWXH(cm) Package size DXWXH(cm) Weight (kg) Qty
Single-phase two-wire(desk type) SVC-500 17X19X13 44X25X35 5.0 4
SVC-1000 20X22X16 50X28X40 7.0 4
SVC-1500 20X22X16 50X28X40 8.0 4
SVC-2000 26X24X19 34X32X50 14 2
SVC-3000 29X22X24 62X38X34 16 2
SVC-5000 46X24X19 54X32X27 27 1
SVC-8000 57X27X24 71X40X35 40 1
SVC-10000 57X27X24 70X40X35 41 1
Three-phase four-wire SVC-1500 40X36X17 52X48X28 18 1
SVC-3000 42X38X19 54X50X31 23 1
SVC-4500 42X38X19 54X50X31 27 1
SVC-6000 37X28X68 48X40X78 39 1
SVC-9000 35X33X78 48X45X90 48 1
SVC-15000 43X38X73 55X51X90 85 1
Single-phase two-wire(desk type) SVC-5000 29X24X40 31X29X48 28.5 1
SVC-8000 29X24X42 40X35X52 39 1
SVC-10000 29X24X42 40X35X52 40 1
SVC-15000 40X33X65 48X45X90 75 1
SVC-20000 58X35X68 68X48X90 110 1
SVC-30000 53X43X102 64X53X112 165 1
SVC-45000 79X43X129 90X65X140 200 1
SVC-60000 79X43X129 90X65X140 250 1
Three-phase four-wire SVC-20000 43X51X91 64X55X106 124 1
SVC-30000 43X51X91 64X55X106 131 1
SVC-45000 65X43X95 78X55X110 197 1
SVC-60000 77X55X100 90X67X115 260 1
SVC-80000 77X55X100 90X67X115 290 1
SVC-100000 77X55X100 90X67X115 350 1

[Download not found] SVC-1KVA Single Phase Desk Type Servo Motor Voltage Regulator suit for office equipment, test equipment, medical equipment, industrial automation equipment, household lighting system, communication system, etc.

Categories
Universal Sockets

Meba electric wall socket MS-6P-2015

Meba electric sockets MS-6P-2015

1. Shell: Aluminum alloy
2. Protection:
2. Control: Multi-function anti-lighting and anti-surge device
4. Certification: CE, RoHS
5. Export Markets: Gobal
6. Productioin Capacity: 200, 000/Year
7. Packing: Carton with PE

Meba electric sockets MS-6P-2015

Technical Parameter:

Model No: MS 6P /2015

Rated Voltage : 250 VAC

Rated Frequency : 50/60 Hz

Rated Current: 16 A

Surrounding Temperature : -10 To + 60 ℃

Humidity : 60 % At + 40 C

Overload Breaking Capacity : 16 A

Standard: UL817, CSA 22.2 , CEE7 V11

Packing way: Standard export carton box

Certificate: CE

Categories
Universal Sockets

Meba electric sockets MS-4P-2035

Meba electric sockets MS-4P-2035

1. Shell: Aluminum alloy
2. Protection:
2. Control: Multi-function anti-lighting and anti-surge device
4. Certification: CE, RoHS
5. Export Markets: Gobal
6. Productioin Capacity: 200, 000/Year
7. Packing: Carton with PE

Meba electric sockets MS-4P-2035

Technical Parameter:

Rated Voltage : 250 VAC

Rated Frequency : 50/60 Hz

Rated Current: 16 A

Surrounding Temperature : -10 To + 60℃

Humidity : 60 % At + 40 C

Overload Breaking Capacity : 16 A

Standard: UL817, CSA 22.2 , CEE7 V11

Packing way: Standard export carton box

Certificate: CE

Categories
C Series Moulded Case Circuit Breaker

Meba Shunt Trip Unit Circuit Breaker‎‎ H400h

·Brief description
1. Compared with traditional circuit breaker or relevant fuse,MEBA C series circuit breaker has excellent protection performance in smaller space, in maximum range can satisfy rated current and faulty current’s requirement.
2. C series  circuit breaker  can  be used in cascade system,  meet next stage circuit breaker’s limit section capacity select protection req-uirement, save whole system cost.
C series circuit breaker complies with IECZ60947-2 international standard;  also comply with main industrial countries standard.
·Features
1. C series  circuit  breaker  including 7 basic frames, frame current from  100  to  2500A.  Each  frame  has up to  415V 100KA (AC240V 200KA)short circuit breaking capacity multiple choice, more flexibility in design, and save space as well.
2. Actually, using  C series  circuit breaker  can  avoid  in  re-design system.  It  can be used in original  switchboard,  feeder ark, bus duct, equipment control panel,  motor  control  center  substitute of old type circuit  breaker.  At  most situations,  can  adopt  same Connector bar, terminal and shaft structure.
3. Circuit  breaker  stan dard  temperature  is  40  degree,  for other higher  ambient  temperature  situation,  can  use  50  degree  factory finalize type design circuit breaker.
4. C series circuit breaker can be used in DC situation as well, 630A frame  3P  circuit breaker   concatenation  used  in  DC600V  breaking capacity can reach 40KA.

·Most reasonable contact terminal system design
C series circuit breaker flexible and special specific is adopt one of the most reasonable design in circuit breaker history, can assure circuit breaker in high fault current fast and reliable breaking.

·Whole testing process in factory
Each C series circuit breaker steady and reliable quality is acc-ording to a whole testing procedure assurance, each circuit breaker’s same pole has to make two times setting test to verify trip,  operating characteristic and electric circuit contentiously.

·High breaking capacity in smaller space
C circuit breaker in shape and electric function can be interchan-ged with Westinghouse moulded case circuit breaker, this means C series circuit breaker is ideal product after  improve its equipment design.

·Operation structure
1.C  series  circuit breaker adopt in fast-separate  and  fast-close mechanical  operation,  which has free trip function,  assure  circuit breaker in short circuit time can not keep closed.
2. Circuit  breaker’s  trip shaft’s  position and two sides’  windows point its working condition:  ‘witch-on’, ‘reak- brake’ and ‘rip’ If circuit breaker overloading,  short circuit, shunt  or  under voltage or press TEST button makes trip, shaft will slip to ‘rip’ position. At mean while if need  circuit  breaker re-switch on,  it should switch shaft to reset position then break brake.

·Current limit feature
   C series circuit breaker adopts high repulsion contact terminal structure and advantage ARC technology, so it has significant currentlimit function.

·Standard
  IEC60947-1:General rule
IEC60947-2:Circuit breaker
IEC60947-3:Switch, isolating switch, load switch etc.

C Series Trip unit type work

H126h-Parameter

Working condition:
1.The altitude not exceeding 2000m
2.The ambient temperature is from +40°Cto -5°C
3.Ambient environment is free from explosive danger and air or dust, which may cause corrosion of metal or weakness of insulation.
4.Ambient environment is free from erosion of rain or snow.
5.Pollution degree 3
6.Over-voltage category III

C series MCCB Structure

 

[Download not found]Meba shunt trip unit circuit breaker‎‎‎ H400h is big ampere circuit breaker  with high breaking capacity match with RCCB, MCB  use  to protection power distribution equipment safety.
It can make and break the nonfrequently circuit in the normal conditions. It takes protect effect when mouse cage motors non-frequent start, breaking off working and protecting overload, short circuit and lacking
voltage.

Categories
Universal Sockets

Meba electric socket MS-4P-2025

Meba electric socket MS-4P-2025

1. Shell: Aluminum alloy
2. Protection:
2. Control: Multi-function anti-lighting and anti-surge device
4. Certification: CE, RoHS
5. Export Markets: Gobal
6. Productioin Capacity: 200, 000/Year
7. Packing: Carton with PE

Meba electric socket MS-4P-2025

Technical Parameter:

Model No: MS 4P /2025

Rated Voltage : 250 VAC

Rated Frequency : 50/60 Hz

Rated Current: 16 A

Surrounding Temperature : -10 To + 60 C

Humidity : 60 % At + 40 C

Overload Breaking Capacity : 16 A

Standard: UL817, CSA 22.2 , CEE7 V11

Packing way: Standard export carton box

Certificate: CE

Categories
Universal Sockets

Meba electric plug socket MS2035

Meba electric plug socket MS2035

[tab]

[tab_item title=”Specification”]

Meba electric plug socket MS2035

1. Shell: Aluminum alloy
2. Protection:
2. Control: Multi-function anti-lighting and anti-surge device
4. Certification: CE, RoHS
5. Export Markets: Gobal
6. Productioin Capacity: 200, 000/Year
7. Packing: Carton with PE

[/tab_item]

[tab_item title=”Parameter”]

Meba electric plug socket MS2035

Technical Parameter:

Model No: MS 3P /2035

Rated Voltage : 250 VAC

Rated Frequency : 50/60 Hz

Rated Current: 16 A

Surrounding Temperature : -10 To + 60 ℃

Humidity : 60 % At + 40 C

Overload Breaking Capacity : 16 A

Standard: UL817, CSA 22.2 , CEE7 V11

Packing way: Standard export carton box

Certificate: CE

[/tab_item]

[tab_item title=”Gallery”]

 

[/tab_item]

 

[/tab_item]

[tab_item title=”PDF Download”]

[/tab_item]

[/tab]

Categories
C Series Moulded Case Circuit Breaker

Meba MCCB For Overload And Short Circuit Protection H226h

[tab]
[tab_item title=”Specification”]

·Brief description
1. Compared with traditional circuit breaker or relevant fuse,MEBA C series circuit breaker has excellent protection performance in smaller space, in maximum range can satisfy rated current and faulty current’s requirement.
2. C series  circuit breaker  can  be used in cascade system,  meet next stage circuit breaker’s limit section capacity select protection req-uirement, save whole system cost.
C series circuit breaker complies with IECZ60947-2 international standard;  also comply with main industrial countries standard.
·Features
1. C series  circuit  breaker  including 7 basic frames, frame current from  100  to  2500A.  Each  frame  has up to  415V 100KA (AC240V 200KA)short circuit breaking capacity multiple choice, more flexibility in design, and save space as well.
2. Actually, using  C series  circuit breaker  can  avoid  in  re-design system.  It  can be used in original  switchboard,  feeder ark, bus duct, equipment control panel,  motor  control  center  substitute of old type circuit  breaker.  At  most situations,  can  adopt  same Connector bar, terminal and shaft structure.
3. Circuit  breaker  stan dard  temperature  is  40  degree,  for other higher  ambient  temperature  situation,  can  use  50  degree  factory finalize type design circuit breaker.
4. C series circuit breaker can be used in DC situation as well, 630A frame  3P  circuit breaker   concatenation  used  in  DC600V  breaking capacity can reach 40KA.

·Most reasonable contact terminal system design
C series circuit breaker flexible and special specific is adopt one of the most reasonable design in circuit breaker history, can assure circuit breaker in high fault current fast and reliable breaking.

·Whole testing process in factory
Each C series circuit breaker steady and reliable quality is acc-ording to a whole testing procedure assurance, each circuit breaker’s same pole has to make two times setting test to verify trip,  operating characteristic and electric circuit contentiously.

·High breaking capacity in smaller space
C circuit breaker in shape and electric function can be interchan-ged with Westinghouse moulded case circuit breaker, this means C series circuit breaker is ideal product after  improve its equipment design.
·Operation structure
1.C  series  circuit breaker adopt in fast-separate  and  fast-close mechanical  operation,  which has free trip function,  assure  circuit breaker in short circuit time can not keep closed.
2. Circuit  breaker’s  trip shaft’s  position and two sides’  windows point its working condition:  ‘witch-on’, ‘reak- brake’ and ‘rip’ If circuit breaker overloading,  short circuit, shunt  or  under voltage or press TEST button makes trip, shaft will slip to ‘rip’ position. At mean while if need  circuit  breaker re-switch on,  it should switch shaft to reset position then break brake.

·Current limit feature
   C series circuit breaker adopts high repulsion contact terminal structure and advantage ARC technology, so it has significant currentlimit function.
·Standard
  IEC60947-1:General rule
IEC60947-2:Circuit breaker
IEC60947-3:Switch, isolating switch, load switch etc.

C Series Trip unit type work

[/tab_item]

[tab_item title=”Technical Parameter”]

H126h-Parameter

Working condition:
1.The altitude not exceeding 2000m
2.The ambient temperature is from +40°Cto -5°C
3.Ambient environment is free from explosive danger and air or dust, which may cause corrosion of metal or weakness of insulation.
4.Ambient environment is free from erosion of rain or snow.
5.Pollution degree 3
6.Over-voltage category III

C series MCCB Structure

 

[/tab_item]

[tab_item title=”PDF Download”]

 [Download not found]Meba MCCB For Overload And Short Circuit Protection H226h is big ampere circuit breaker  with high breaking capacity match with RCCB, MCB  use  to protection power distribution equipment safety. [/tab_item]
[/tab]

Categories
Universal Sockets

Meba electric plug MS2025

Meba electric plug MS2025

[tab]

[tab_item title=”Specification”]

Meba electric plug MS2025

1. Shell: Aluminum alloy
2. Protection:
2. Control: Multi-function anti-lighting and anti-surge device
4. Certification: CE, RoHS
5. Export Markets: Gobal
6. Productioin Capacity: 200, 000/Year
7. Packing: Carton with PE

[/tab_item]

[tab_item title=”Parameter”]

Meba electric plug MS2025

Technical Parameter:

Model No: MS 3P /2025

Rated Voltage : 250 VAC

Rated Frequency : 50/60 Hz

Rated Current: 16 A

Surrounding Temperature : -10 To + 60 ℃

Humidity : 60 % At + 40 C

Overload Breaking Capacity : 16 A

Standard: UL817, CSA 22.2 , CEE7 V11

Packing way: Standard export carton box

Certificate: CE

[/tab_item]

[tab_item title=”Gallery”]

 

[/tab_item]

 

[/tab_item]

[tab_item title=”PDF Download”]

[/tab_item]

[/tab]

Categories
Automatic Voltage Regulator

Meba Automatic Control Circuit Regulator SVC-1500VA

[tab]
[tab_item title=”Specification”]

General:

SVC single-phase and three-phase high accuracy full-automatic AC voltage stabilizer is one kind of our dominant products, made up of contact auto voltage regulator, servo motor, automatic control circuit, etc.

When the power network voltage fluctuates or the load varies, automatic sampling control circuit will send signal to drive the servo motor which can adjust the position of carbon brush of auto voltage regulator, then, the output voltage will be adjusted to rated value and get a steady state.

It has excellent features, such as elegant appearance, compact structure, light weight, small waveform distortion, high efficiency, stable and reliable performance and so on.

This product is an ideal stabilized voltage supply, widely used in any locations requiring electricity and ensures your power device can run normally.

Application:

For office equipment, test equipment, lighting systems, safety alarm systems, communication systems, medical equipment, duplicators, stereo sound equipment, industrial automatic equipment, color film developing equipment, digital control machine tools, checkout equipment, TV sets, office appliances.

Performance:

Single-phase input voltage Single phase 160V-250V
Single-phase output voltage 1. 0.5KVA~3KVA: Single -phase 220V and 110V
2. 5KVA~30KVA: Single -phase 220V
Three-phase input voltage 1. Phase voltage 160-250V
2. Wire voltage 227-430V
Three-phase output voltage 1. Phase voltage 220V
2. Wire voltage 380V
Voltage stabilizing precision 220V±3% 110V±6%
Frequency 50Hz/60Hz
Adjustable time <1s(when input voltage has a change of 10%)
Efficiency >90%
Over-voltage protection 246V±4V
Delay time Long 5min±2min, short 5s±2s
Ambient temperature -5℃ ~ +40℃
Relative humidity ≤90%
Waveform distortion No additional waveform distortion
Load power factor 0.8
Dielectric strength 1500V/1min
lnsulation resistance ≥2MΩ

 

Model and Sepc:

Spec(VA) Product size DXWXH(cm) Package size DXWXH(cm) Weight (kg) Qty
Single-phase two-wire(desk type) SVC-500 17X19X13 44X25X35 5.0 4
SVC-1000 20X22X16 50X28X40 7.0 4
SVC-1500 20X22X16 50X28X40 8.0 4
SVC-2000 26X24X19 34X32X50 14 2
SVC-3000 29X22X24 62X38X34 16 2
SVC-5000 46X24X19 54X32X27 27 1
SVC-8000 57X27X24 71X40X35 40 1
SVC-10000 57X27X24 70X40X35 41 1
Three-phase four-wire SVC-1500 40X36X17 52X48X28 18 1
SVC-3000 42X38X19 54X50X31 23 1
SVC-4500 42X38X19 54X50X31 27 1
SVC-6000 37X28X68 48X40X78 39 1
SVC-9000 35X33X78 48X45X90 48 1
SVC-15000 43X38X73 55X51X90 85 1
Single-phase two-wire(desk type) SVC-5000 29X24X40 31X29X48 28.5 1
SVC-8000 29X24X42 40X35X52 39 1
SVC-10000 29X24X42 40X35X52 40 1
SVC-15000 40X33X65 48X45X90 75 1
SVC-20000 58X35X68 68X48X90 110 1
SVC-30000 53X43X102 64X53X112 165 1
SVC-45000 79X43X129 90X65X140 200 1
SVC-60000 79X43X129 90X65X140 250 1
Three-phase four-wire SVC-20000 43X51X91 64X55X106 124 1
SVC-30000 43X51X91 64X55X106 131 1
SVC-45000 65X43X95 78X55X110 197 1
SVC-60000 77X55X100 90X67X115 260 1
SVC-80000 77X55X100 90X67X115 290 1
SVC-100000 77X55X100 90X67X115 350 1

[/tab_item]

[tab_item title=”PDF Download”] [Download not found] SVC 1.5KVA Automatic Control Circuit Regulator suit for office equipment, test equipment, medical equipment, industrial automation equipment, household lighting system, communication system, etc.

[/tab_item]
[/tab]

 

Categories
C Series Moulded Case Circuit Breaker

Meba MCCB Circuit Breaker H126h

[tab]
[tab_item title=”Specification”]

·Brief description
1. Compared with traditional circuit breaker or relevant fuse,MEBA C series circuit breaker has excellent protection performance in smaller space, in maximum range can satisfy rated current and faulty current’s requirement.
2. C series  circuit breaker  can  be used in cascade system,  meet next stage circuit breaker’s limit section capacity select protection req-uirement, save whole system cost.
C series circuit breaker complies with IECZ60947-2 international standard;  also comply with main industrial countries standard.
·Features
1. C series  circuit  breaker  including 7 basic frames, frame current from  100  to  2500A.  Each  frame  has up to  415V 100KA (AC240V 200KA)short circuit breaking capacity multiple choice, more flexibility in design, and save space as well.
2. Actually, using  C series  circuit breaker  can  avoid  in  re-design system.  It  can be used in original  switchboard,  feeder ark, bus duct, equipment control panel,  motor  control  center  substitute of old type circuit  breaker.  At  most situations,  can  adopt  same Connector bar, terminal and shaft structure.
3. Circuit  breaker  stan dard  temperature  is  40  degree,  for other higher  ambient  temperature  situation,  can  use  50  degree  factory finalize type design circuit breaker.
4. C series circuit breaker can be used in DC situation as well, 630A frame  3P  circuit breaker   concatenation  used  in  DC600V  breaking capacity can reach 40KA.

·Most reasonable contact terminal system design
C series circuit breaker flexible and special specific is adopt one of the most reasonable design in circuit breaker history, can assure circuit breaker in high fault current fast and reliable breaking.

·Whole testing process in factory
Each C series circuit breaker steady and reliable quality is acc-ording to a whole testing procedure assurance, each circuit breaker’s same pole has to make two times setting test to verify trip,  operating characteristic and electric circuit contentiously.

·High breaking capacity in smaller space
C circuit breaker in shape and electric function can be interchan-ged with Westinghouse moulded case circuit breaker, this means C series circuit breaker is ideal product after  improve its equipment design.
·Operation structure
1.C  series  circuit breaker adopt in fast-separate  and  fast-close mechanical  operation,  which has free trip function,  assure  circuit breaker in short circuit time can not keep closed.
2. Circuit  breaker’s  trip shaft’s  position and two sides’  windows point its working condition:  ‘witch-on’, ‘reak- brake’ and ‘rip’ If circuit breaker overloading,  short circuit, shunt  or  under voltage or press TEST button makes trip, shaft will slip to ‘rip’ position. At mean while if need  circuit  breaker re-switch on,  it should switch shaft to reset position then break brake.

·Current limit feature
   C series circuit breaker adopts high repulsion contact terminal structure and advantage ARC technology, so it has significant currentlimit function.
·Standard
  IEC60947-1:General rule
IEC60947-2:Circuit breaker
IEC60947-3:Switch, isolating switch, load switch etc.

H126h-Parameter

[/tab_item]

[tab_item title=”Technical Parameter”]

 

Working condition:
1.The altitude not exceeding 2000m
2.The ambient temperature is from +40°Cto -5°C
3.Ambient environment is free from explosive danger and air or dust, which may cause corrosion of metal or weakness of insulation.
4.Ambient environment is free from erosion of rain or snow.
5.Pollution degree 3
6.Over-voltage category III

C series MCCB Structure

 

[/tab_item]

[tab_item title=”PDF Download”]

 [Download not found]Meba MCCB Circuit Breaker H126h is big ampere circuit breaker  with high breaking capacity match with RCCB, MCB  use  to protection power distribution equipment safety. [/tab_item]
[/tab]

Categories
Automatic Voltage Regulator

Meba SVC Voltage Stabilizer SVC-2000W

[tab]
[tab_item title=”Specification”]

General:

SVC single-phase and three-phase high accuracy full-automatic AC voltage stabilizer is one kind of our dominant products, made up of contact auto voltage regulator, servo motor, automatic control circuit, etc.

When the power network voltage fluctuates or the load varies, automatic sampling control circuit will send signal to drive the servo motor which can adjust the position of carbon brush of auto voltage regulator, then, the output voltage will be adjusted to rated value and get a steady state.

It has excellent features, such as elegant appearance, compact structure, light weight, small waveform distortion, high efficiency, stable and reliable performance and so on.

This product is an ideal stabilized voltage supply, widely used in any locations requiring electricity and ensures your power device can run normally.

Application:

For office equipment, test equipment, lighting systems, safety alarm systems, communication systems, medical equipment, duplicators, stereo sound equipment, industrial automatic equipment, color film developing equipment, digital control machine tools, checkout equipment, TV sets, office appliances.

Performance:

Single-phase input voltage Single phase 160V-250V
Single-phase output voltage 1. 0.5KVA~3KVA: Single -phase 220V and 110V
2. 5KVA~30KVA: Single -phase 220V
Three-phase input voltage 1. Phase voltage 160-250V
2. Wire voltage 227-430V
Three-phase output voltage 1. Phase voltage 220V
2. Wire voltage 380V
Voltage stabilizing precision 220V±3% 110V±6%
Frequency 50Hz/60Hz
Adjustable time <1s(when input voltage has a change of 10%)
Efficiency >90%
Over-voltage protection 246V±4V
Delay time Long 5min±2min, short 5s±2s
Ambient temperature -5℃ ~ +40℃
Relative humidity ≤90%
Waveform distortion No additional waveform distortion
Load power factor 0.8
Dielectric strength 1500V/1min
lnsulation resistance ≥2MΩ

 

Model and Sepc:

Spec(VA) Product size DXWXH(cm) Package size DXWXH(cm) Weight (kg) Qty
Single-phase two-wire(desk type) SVC-500 17X19X13 44X25X35 5.0 4
SVC-1000 20X22X16 50X28X40 7.0 4
SVC-1500 20X22X16 50X28X40 8.0 4
SVC-2000 26X24X19 34X32X50 14 2
SVC-3000 29X22X24 62X38X34 16 2
SVC-5000 46X24X19 54X32X27 27 1
SVC-8000 57X27X24 71X40X35 40 1
SVC-10000 57X27X24 70X40X35 41 1
Three-phase four-wire SVC-1500 40X36X17 52X48X28 18 1
SVC-3000 42X38X19 54X50X31 23 1
SVC-4500 42X38X19 54X50X31 27 1
SVC-6000 37X28X68 48X40X78 39 1
SVC-9000 35X33X78 48X45X90 48 1
SVC-15000 43X38X73 55X51X90 85 1
Single-phase two-wire(desk type) SVC-5000 29X24X40 31X29X48 28.5 1
SVC-8000 29X24X42 40X35X52 39 1
SVC-10000 29X24X42 40X35X52 40 1
SVC-15000 40X33X65 48X45X90 75 1
SVC-20000 58X35X68 68X48X90 110 1
SVC-30000 53X43X102 64X53X112 165 1
SVC-45000 79X43X129 90X65X140 200 1
SVC-60000 79X43X129 90X65X140 250 1
Three-phase four-wire SVC-20000 43X51X91 64X55X106 124 1
SVC-30000 43X51X91 64X55X106 131 1
SVC-45000 65X43X95 78X55X110 197 1
SVC-60000 77X55X100 90X67X115 260 1
SVC-80000 77X55X100 90X67X115 290 1
SVC-100000 77X55X100 90X67X115 350 1

[/tab_item]

[tab_item title=”PDF Download”] [Download not found] SVC-2KVA SVC Voltage Stabilizer suit for office equipment, test equipment, medical equipment, industrial automation equipment, household lighting system, communication system, etc.

[/tab_item]
[/tab]

 

Categories
Universal Sockets

Meba electric outlet MS-5P-2035

Meba electric outlet MS-5P-2035

1. Shell: Aluminum alloy
2. Protection:
2. Control: Multi-function anti-lighting and anti-surge device
4. Certification: CE, RoHS
5. Export Markets: Gobal
6. Productioin Capacity: 200, 000/Year
7. Packing: Carton with PE

Meba electric light socket MS-5P-2015

Technical Parameter:

Model No: MS 5P /2035

Rated Voltage : 250 VAC

Rated Frequency : 50/60 Hz

Rated Current: 16 A

Surrounding Temperature : -10 To + 60 C

Humidity : 60 % At + 40 C

Overload Breaking Capacity : 16 A

Standard: UL817, CSA 22.2 , CEE7 V11

Packing way: Standard export carton box

Certificate: CE