Categories
Front Board Mounted KWH Meters

Meba- Energy Meters Digital -MB073RJ

Application

Meba energy meters digital MB073RJ is a kind of new style single phase two wire active energy meter, it is designed on the basis of original DD862 single phase electromechanical meter, and fully absorb new technologies about electromechanical meter from domestic and abroad. The meter completely accord with relevant technical requirements of class 2 single phase active energy meter stipulated in international standard IEC 62053-11. It can accurate and directly measure 50Hz or 60Hz active energy consumption from single phase AC electricity net, it is use for setting indoor or out door meter box. The meter has novel design, rational structure, and it can display total energy consumption by drum wheel mechanical register. It has following features: high overload, power loss, long-life, specious appearance, etc.

Technical Data

Model Accuracy Reference Voltage(V) Current specifications(A) Starting current(A) Insulation performance
MB073RJ Class 2 127
230
5(20)
10(40)
20(80)
30(100)
0.025
0.05
0.1
0.15
AC voltage 2kv for 1 minute,
1.2/50us waveform
pulse voltage 6kv

Installing Diagram

 

Dimension for MB073RJ
Dimension for MB073RJ

 

 

 

Wiring diagram for MB073RJ
Wiring diagram for MB073RJ

1. Front board three fixed installation, the cover is made of high definition transparent glass material molded overall, the bottom of the meter and the terminal is made of quality bakelite material which is moisture-resistant, fire-retardant, high temperature molded overall. It has following features: good weatherability, high rigid, specious appearance, etc.
2. The meter frame adopt aluminum molding with excellent mechanical strength, stable structure and anti-impact.
3. Voltage components and current components is used of double insulation structure, has good electrical characteristics.
4. Standard configuration bottom bearing is used of double gem bearing, oriented bearing is made of high wear resistance copper alloy bush and stainless steel needle. It has following features: long life and minimal friction, etc. May select magnetic thrust bearing (Product Configuration code is RD).
5. All kinds of adjustment mechanism adopt no step shifting mechanism. The meter starting and creeping needn’t to be adjust which is finished by anti-creeping hole of disc and convenient for adjusting by users.
6. Standard configuration 6 digits display by drum wheel mechanical register, may select 5 digits display by drum wheel mechanical register (Product Configuration code is RG).
7. Standard configuration without the device which can prevent retrograde, may select add the function of prevent retrograde. (Please specified when ordering).
8. Single component measure single phase two wire active energy consumption. Complying with standard IEC 62053-11.
9. Direct connect operation, there are two types wiring you may select. Standard configuration type 1B wiring, may select type 1A wiring (Product Configuration code is RK).
10. Extension terminals cover, in order to protect to use safety.

[Download not found]
Categories
Front Board Mounted KWH Meters

Meba-standard active meter -MB341AM

Application

 Meba standard active meter  MB341AM  is a kind of three phase four wire three tariffs (time-sharing billing)active energy meter, the meter completely accord with relevant technical requirements of class 1 three phase active energy meter stipulated in international standard IEC 62053-21. It can accurate and directly measure 50Hz or 60Hz active energy consumption from three phase four wire AC electricity net, it is use for setting indoor or out door meter box. This meter has seven digits LCD displays shows various consumption data and information. And there are far infrared and RS485 communication module in it. It is use for setting and reading the meter. Contact with all kind of AMR system conveniently. It has following features: good reliability, light weight, specious nice appearance, convenient installation, etc.

Technical Data

Model Accuracy Reference Voltage(V) Current specifications(A) Starting current(A) Insulation performance
MB341AM Class 1 3X127/220
3X230/440
5(30)
10(60)
20(100)
0.02
0.04
0.08
AC voltage 4kv for 1 minute,
1.2/50us waveform
pulse voltage 6kv

 

Installing Diagram

 

Dimension for MB341AM
Dimension for MB341AM

 

 

 

Wiring diagram for MB341AM
Wiring diagram for MB341AM

1. Front board three fixed installation, up and down mounting holes center distance is 198-212 mm, users can choose any one by themselves.
2. Have three tariffs, may select 12 daily period of times. You can set the date arbitrary which can automatic read the meter every month. May select single tariff function in weekend. (Please specified when ordering)
3. There are a clock and Maintenance-free backup lithium batteries in it. Battery capacity detection and display all the time. It can keep the electricity data for 12 months. The data can be kept forever after power cut off.
4. May select cycle display (default) or push the button itemized display, we can set the cycle display, it can display 14 data at most. Can select the data which displayed. The decimal median which displayed can choose set one or two.
5. There are a polarity port of pulse output passive closed and a nonpolarity port of pulse output passive distant, the output rate is 10 or 100 imp/kWh (can select), Complying with standard IEC 62053-31 and DIN 43864.
6. There are far infrared and a port of RS485 communication data. It is use for setting and reading the meter. Set and operation have password protection, communication agreement complying with standard DL/T645-1997.
7. Ten LED instructions respectively power supply state, signal of energy impulse, the direction of the flow of load current, the state rates just now and the data communications state.
8. Single direction three components measure three phase four wire active energy consumption. It is nothing with direction of the flow of load current. Complying with standard IEC 62053-21.
9. Standard configuration for direct connect operation, type 16B wiring, we can also choose another type of wiring, and use CT (Product Configuration code is AO) and PT & CT (Product Configuration code is AQ), type 48B wiring for operation.
10. Standard configuration extension terminals cover, in order to protect to use safety, may select short terminals cover.  (Product Configuration code is AL).