Categories
G series Moulded Case Circuit Breaker

Meba Mcb And Mccb HJW-250

Meba Mcb And Mccb HJW-250

·Brief description
G series moulded case circuit breaker not only has compact volume than normal circuit breaker or fuse, but
also supply more advanced performance. Advantages as following:

■Easy installation accessory

■Easy installation accessory

■20A-2500A can equip with electronic trip

■Built in 20A earth fault protection

·Application
HJW-250 is one kind of latest developed molded case circuit breaker in our factory, it is according to cutler-hammer technology, at present we mainly export to South America and Middle East countries, quality is satisfied by our customers.

·Operating mechanism
1.
G circuit breaker adopts shaft operation feature, this shaft can instruct circuit breaker’s  working condition: ON OFF and PIPPED.

2. When circuit breaker appear overloading, short circuit, shunt or under voltage trip action, shaft will jump to TRIPPED (trip) position, at this time, if need to re-switch on must push shaft to RESET position.

3. On both sides of shaft on EG and RG frame there will have 2 windows, which direct circuit breaker’s  working condition, red, green and white each correspondence  to: On/OFF/TRIPPED.

Type G F J K L
Frame Current(A) 100 225 250 400 630
Culter-hammer Specifications GWF FW HFW FWH HFWF HJW HKW HLW
Rated Current(A) 16-100 16-225 125-250 125-400 315-600
Number of Poles 3 Poles
Breaking Capacity(kA, rms), AC50/60Hz
IEC60947-2 220-240V AC Icu 65 85 100 85 100 100 100 100
Ics 33 85 100 85 100 100 100 100
380-415V AC Icu 25 40 70 40 70 70 70 70
Ics 13 40 70 40 70 70 70 70
660-690V AC Icu 12 14 12 14 18 25 25
Ics 6 7 6 7 9 13 13
250V DC Icu 10 10 20 10 20 20 20 20
Ics 5 5 10 5 10 10 10 10
NEMA 240V AC 65 65 100 65 100 100 100 100
480VAC 22 25 65 25 65 65 65 65
600VAC 18 25 18 25 25 35 35
Rated Insulation Voltage Main Circuit 750VAC
Auxiliary Circuit 690VAC
Uimp Main Circuit 6kV 8kV
Auxiliary Circuit 4kV
Rated Working Voltage, Ue 440 690
Ambient Temperature From -20 to +70
Size(mm) H 123.8 152.4 177.8 280 273
W 76.2 105 105 140 210
D 66.7 86 103 104 104
Weight(kg) 1 2.4 5.2 6.1 9.4

Working condition:
1.The altitude not exceeding 2000m
2.The ambient temperature is from +40°Cto -5°C
3.Ambient environment is free from explosive danger and air or dust, which may cause corrosion of metal or weakness of insulation.
4.Ambient environment is free from erosion of rain or snow.
5.Pollution degree 3
6.Over-voltage category III

[Download not found] Meba Mcb And Mccb HJW250 is big ampere circuit breaker  with high breaking capacity match with RCCB, MCB  use  to protection power distribution equipment safety.

Categories
MTmax Moulded Case Circuit Breaker

Meba Moulded Case Circuit Breakers EZC-250F

1. EZC-250F MCCB series is one of breakers which adopts international advanced design, manufacture technology to develop.

2.The rated insulating voltage is 500V, suitable for AC 50Hz(60Hz), rated working voltage 500V or below, rated working current is 15A to 250A of circuit and use in distributing electric energy.

3. It complies with standard of IEC60947-2.

Classification:

1. Installation way: Mounted vertically, Horizontal installation;
2. By use of circuit breaker usage: Distribution protection, Motor protection;
3. According to the mode of wiring points: Front panel wiring, Back panel wiring , Plug-in connection;
4. According to the mode of operation: direct operating handle, External turning the handle operations, electric operation;
5. By release type distinction: instantaneous action release (magnetic release), thermal + electromagnetic release (duplex); electronic release;
6. Poles Number: 3poles, 4poles;

Type

EZC60E

EZC100B

EZC100D

EZC160D

EZC250D

Poles No.

3

3

3

3

3

Rated Current In(A)

15, 20, 25, 30, 40, 50, 60

15, 20, 25, 30, 40, 50, 60, 75, 80, 100

15, 20, 25, 30, 40, 50, 60, 75, 80, 100

125, 160

200, 225, 250

Rated Operating Voltage Ue(V)(50/60Hz)

500

500

500

500

500

Rated Insulation Voltage Ui(V)

500

500

500

500

500

Rated Impulse Voltage Uimp(Kv)

6

6

6

6

6

Utilisation Category

A

A

A

A

A

Rated Limited Breaking Capacity Icu(KA)

220/240V

7.5

25

25

85

85

380V

7.5

10

18

18

18

400V

7.5

10

15

15

15

Rated Used Breaking Capacity Ics(%Icu)

25

50

50

50

50

Working condition:
1.The altitude not exceeding 2000m
2.The ambient temperature is from +40°Cto -5°C
3.Ambient environment is free from explosive danger and air or dust, which may cause corrosion of metal or weakness of insulation.
4.Ambient environment is free from erosion of rain or snow.
5.Pollution degree 3
6.Over-voltage category III

Trip characteristic:
The thermodynamic release of the breaker has the advantages of inverse time-delay while the magnetic release the instantaneous operation as shown on table 2(distribution circuit breaker)and table 3(motor protection circuit breaker).

Overall & Installation Dimensions:

EZC Series Overall & Installation Dimensions

[Download not found] Meba Moulded Case Circuit Breakers EZC-250F is big ampere circuit breaker  with high breaking capacity match with RCCB, MCB  use  to protection power distribution equipment safety.