Categories
MTmax Moulded Case Circuit Breaker

Meba Automatic Regulation Moulded Case Circuit Breaker MTmax-160A-3P

1.MTmax series power moulded case circuit breaker is the lasted model of MCCB, suitable for circuit AC 50Hz/60Hz, rated voltage up to AC 660V, rated operating current up to 1600A.

2.It features normal structure, reliable performance, high breaking capacity.

3.Used for power distribution and protecting the circuit and electrical equipment against overload and short circuit.

4.It complies with standard of IEC60947-2.

Classification:

1. Installation way: Mounted vertically, Horizontal installation;
2. By use of circuit breaker usage: Distribution protection, Motor protection;
3. According to the mode of wiring points: Front panel wiring, Back panel wiring , Plug-in connection;
4. According to the mode of operation: direct operating handle, External turning the handle operations, electric operation;
5. By release type distinction: instantaneous action release (magnetic release), thermal + electromagnetic release (duplex); electronic release;
6.  Poles Number: 3poles, 4poles;

Type MTMAX-160 MTMAX-250
Poles No. 3 3
Rated current In(A) 16-160 100-250
Rated operating voltage Ue(V)(50/60Hz) 690 690
Rated insulation voltage Ui(V) 800 800
Rated impulse withstand voltage Uimp(KV) 8 8
Utilisation category A A
Rated limited short-circuit breaking capacity Icu(KA) 220/230V 25 50
380/415V 16 36
400V 10 25
500V 8 20
690V 3 5
500V-3poles in series 16 36
Rated short-circuit service breaking capacity Ics 100 75

 

Outline and Installation Dimension

[Download not found]

MTmax series 160A automatic regulation moulded case circuit breaker with different rated current mainly protecting the circuit and electrical equipment against overload and short circuit.

Categories
C Series Moulded Case Circuit Breaker

Meba MCCB E2KM 400A

·Brief description
1. Compared with traditional circuit breaker or relevant fuse,MEBA C series circuit breaker has excellent protection performance in smaller space, in maximum range can satisfy rated current and faulty current’s requirement.
2. C series  circuit breaker  can  be used in cascade system,  meet next stage circuit breaker’s limit section capacity select protection req-uirement, save whole system cost.
C series circuit breaker complies with IECZ60947-2 international standard;  also comply with main industrial countries standard.

·Features
1. C series  circuit  breaker  including 7 basic frames, frame current from  100  to  2500A.  Each  frame  has up to  415V 100KA (AC240V 200KA)short circuit breaking capacity multiple choice, more flexibility in design, and save space as well.
2. Actually, using  C series  circuit breaker  can  avoid  in  re-design system.  It  can be used in original  switchboard,  feeder ark, bus duct, equipment control panel,  motor  control  center  substitute of old type circuit  breaker.  At  most situations,  can  adopt  same Connector bar, terminal and shaft structure.
3. Circuit  breaker  stan dard  temperature  is  40  degree,  for other higher  ambient  temperature  situation,  can  use  50  degree  factory finalize type design circuit breaker.
4. C series circuit breaker can be used in DC situation as well, 630A frame  3P  circuit breaker   concatenation  used  in  DC600V  breaking capacity can reach 40KA.

·Most reasonable contact terminal system design
C series circuit breaker flexible and special specific is adopt one of the most reasonable design in circuit breaker history, can assure circuit breaker in high fault current fast and reliable breaking.

·Whole testing process in factory
Each C series circuit breaker steady and reliable quality is acc-ording to a whole testing procedure assurance, each circuit breaker’s same pole has to make two times setting test to verify trip,  operating characteristic and electric circuit contentiously.

·High breaking capacity in smaller space
C circuit breaker in shape and electric function can be interchan-ged with Westinghouse moulded case circuit breaker, this means C series circuit breaker is ideal product after  improve its equipment design.

·Operation structure
1.C  series  circuit breaker adopt in fast-separate  and  fast-close mechanical  operation,  which has free trip function,  assure  circuit breaker in short circuit time can not keep closed.
2. Circuit  breaker’s  trip shaft’s  position and two sides’  windows point its working condition:  ‘witch-on’, ‘reak- brake’ and ‘rip’ If circuit breaker overloading,  short circuit, shunt  or  under voltage or press TEST button makes trip, shaft will slip to ‘rip’ position. At mean while if need  circuit  breaker re-switch on,  it should switch shaft to reset position then break brake.

·Current limit feature
   C series circuit breaker adopts high repulsion contact terminal structure and advantage ARC technology, so it has significant currentlimit function.

·Standard
  IEC60947-1:General rule
IEC60947-2:Circuit breaker
IEC60947-3:Switch, isolating switch, load switch etc.

C Series Trip unit type work

E2FM 225 Parameter

Working condition:
1.The altitude not exceeding 2000m
2.The ambient temperature is from +40°Cto -5°C
3.Ambient environment is free from explosive danger and air or dust, which may cause corrosion of metal or weakness of insulation.
4.Ambient environment is free from erosion of rain or snow.
5.Pollution degree 3
6.Over-voltage category III

C series MCCB Structure

[Download not found]Meba MCCB E2KM 400A is big ampere circuit breaker  with high breaking capacity match with RCCB, MCB  use  to protection power distribution equipment safety.