Categories
Residual Current Circuit Breaker

Meba Residual Current Device Operation OLL2-4P

Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: OLL2
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 4P

Application:

1. OLL2, Residual Current Devices for earth leakage detection.

2. It is to be used in association with miniature circuit breakers, its function is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.

3. These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.

Merits:

Good quality , high breaking capability, updated structure,quick trip and guide installation, competitive price,excellent and safe performance,beautiful and compact appearance, etc .

Mounting Requirements:

1. Circumstance temperature -5°C ~ +40°C, average temperature not exceeding 35°C.
2. Altitude above sea level less than 2000 m.
3. Humidity not exceeding 50% at 40°C and not exceeding 90% at 25°C.
4. Installation class II or III.
5. Pollution class 2.
6. Installation method DIN Rail mounting type.
7. The external magnetism shall not be more than 5 times of terrestrial one.
8. Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position.

1. Electromagnetic and Electronic type
2. 70mm wide for 2 pole Din Rail installation.
3. Standsrd: IEC1008/EN61008
4. Rated Voltage(Un): 2pole, 230V AC
5. Rated Current(In): 25, 40, 63A
6. Rated residual operating current(I△n): 30, 100, 300, 500mA
7. Rated residual non-operating current(I△no): 0.5 I△n
8. Residual current off-time: ≤0.1s
9. Minimum value of rated breaking capacity(lm): 630A
10. Rated conditional short-circuit capacity (lnc): 6KA

[Download not found]Meba Residual Current Device Operation OLL2-4P open a circuit automatically in the event of an earth fault between phase and earth and/or netural and earth.

Categories
Residual Current Circuit Breaker

Meba Residual Current Operated Circuit Breakers OLL2-2P

Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: OLL2
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 4P

Application:

1. OLL2, Residual Current Devices for earth leakage detection.

2. It is to be used in association with miniature circuit breakers, its function is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.

3. These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.

Merits:

Good quality , high breaking capability, updated structure,quick trip and guide installation, competitive price,excellent and safe performance,beautiful and compact appearance, etc .

Mounting Requirements:

1. Circumstance temperature -5°C ~ +40°C, average temperature not exceeding 35°C.
2. Altitude above sea level less than 2000 m.
3. Humidity not exceeding 50% at 40°C and not exceeding 90% at 25°C.
4. Installation class II or III.
5. Pollution class 2.
6. Installation method DIN Rail mounting type.
7. The external magnetism shall not be more than 5 times of terrestrial one.
8. Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position.

1. Electromagnetic and Electronic type
2. 35mm wide for 2 pole Din Rail installation.
3. Standsrd: IEC1008/EN61008
4. Rated Voltage(Un): 2pole, 230V AC
5. Rated Current(In): 25, 40, 63A
6. Rated residual operating current(I△n): 30, 100, 300, 500mA
7. Rated residual non-operating current(I△no): 0.5 I△n
8. Residual current off-time: ≤0.1s
9. Minimum value of rated breaking capacity(lm): 630A
10. Rated conditional short-circuit capacity (lnc): 6KA

[Download not found]Meba Residual Current Operated Circuit Breakers OLL2-2P open a circuit automatically in the event of an earth fault between phase and earth and/or netural and earth.

Categories
Residual Current Circuit Breaker

Meba Residual Current Measurement MBEFI 4P

1. Residual current circuit breakers MBEFI are used for protection against indirect touching of parts under voltage.

2. For prevention of lasting voltage on earthed parts which should appear because of a defect in the electrical installation and for protection against direct contacts of parts under voltage in case of I n 30mA.

3. Residual current circuit breakers can be used in TN-S, TN-C, TT and IT network systems or with other words in all systems where neutral and protective conductor are separated (VDE 0100 Teil 410).

4. Types – Our programme comprises residual current circuit breakers which are sensitive to alternating residu al current (AC-type) and residual current circuit breakers which are sensitive to alternating and pulsating direct current (A-type).

Merits:

Good quality , high breaking capability, updated structure,quick trip and guide installation, competitive price,excellent and safe performance,beautiful and compact appearance, etc .

MBEFI2 MBEFI4
type A type AC type G type A type AC type S type G
For alternating residual current
For alternating and pulsating direct residual current
Short-circuit capacity with back-up fuse
VDE 0664, part 1(up to 80A)
lower temperature limit of application -25℃
Selective (time delayed min. 40 ms)
Short time delayed (min. 10 ms)

MBEFI-4 type A, MBEFI-4 type AC

In [A] IΔn [A] number of poles code No.A code No.AC weight [g] packaging [pcs]
16 0,03 4 002062541 002062141 393 1/27
25 0,03 4 002062542 002062142 393 1/27
40 0,03 4 002062543 002062143 393 1/27
63 0,03 4 002062544 002062144 400 1/27
80 0,03 4 002062545 002062145 407 1/27
100 0,03 4 002062546 002062146 407 1/27
16 0,1 4 002063541 002063141 393 1/27
25 0,1 4 002063542 002063142 393 1/27
40 0,1 4 002063543 002063143 393 1/27
63 0,1 4 002063544 002063144 400 1/27
80 0,1 4 002063545 002063145 407 1/27
100 0,1 4 002063546 002063146 407 1/27
16 0,3 4 002064541 002064141 364 1/27
25 0,3 4 002064542 002064142 364 1/27
40 0,3 4 002064543 002064143 364 1/27
63 0,3 4 002064544 002064144 372 1/27
80 0,3 4 002064545 002064145 372 1/27
100 0,3 4 002064546 002064146 372 1/27
16 0.5 4 002065541 002065141 364 1/27
25 0,5 4 002065542 002065142 364 1/27
40 0,5 4 002065543 002065143 364 1/27
63 0,5 4 002065544 002065144 372 1/27
80 0,5 4 002065545 002065145 372 1/27

* type with N-pole on the left side is also available.

MBEFI-4 type S

In [A] IΔn [A] number of poles code No.AC weight [g] packaging [pcs]
40 0,3 4 002064243 400 1/27
63 0,3 4 002064244 400 1/27

MBEFI-4 type G

In [A] IΔn [A] number of poles code No.AC weight [g] packaging [pcs]
40 0,03 4 002062743* 320 1/27
40 0,1 4 002063743* 320 1/27

*The same housing as MBEFI-4 100 A.

download id=”88″]Meba Residual Current Measurement MBEFI 4P a wide range of current ratings and sensitivities are available. Suitable for domestic, commercial and industrial applications.