1. MBE series MCCB is developed from LS type, suitable for industrial or commercial power and lighting with AC50/60Hz, rated working voltage up to AC600V/DC250V, rated current up to 630A.
2. It’S a kind of economical breaker with the characters of stable and reliable function, beautiful appearance, small size and long life.
3. It can be used for conversion of line and infrequent starting motor. It can also be attached to install the accessories which have protection function for avoiding loss-voltage, undervoltage.
4. The product can install connection line with front board and back board, it also can equip hand-operating apparatus or motor-operating apparatus to control in a remote distance.
The rated insulation voltage for this series of circuit breaker is 690V, the rated operating voltage is 600V, the rated frequency is 50Hz, the other rated values for the main circuit.
|
Type |
2pole |
MBE-32E |
MBE-52E |
MBE-52S |
MBE-62E |
MBE-62S |
|
3pole |
MBE-33S |
MBE-53E |
MBE-53S |
MBE-63E |
MBE-63S |
|
|
Frame size(AF) |
30 |
50 |
60 |
|||
|
Rated current (A) |
5,10,15, |
5,10,15,20 |
60 |
|||
|
Rated operational voltage(V) Ue (50/60Hz) |
600 |
600 |
600 |
600 |
600 |
|
|
Rated insulation voltage(V) Ui (50/60Hz) |
690 |
690 |
690 |
690 |
690 |
|
|
Rated impulse withstand voltage (KV) Uimp |
6 |
6 |
6 |
6 |
6 |
|
|
Ultimate breaking capacity |
220/240V |
10 |
10 |
25 |
10 |
25 |
|
380V |
7.5/5 |
7.5/5 |
14/10 |
7.5/5 |
14/10 |
|
|
415V |
7.5/5 |
7.5/5 |
14/10 |
7.5/5 |
14/10 |
|
|
440/460V |
5 |
5 |
10 |
5 |
10 |
|
|
480/500V |
2.5 |
2.5 |
7.5 |
2.5 |
7.5 |
|
|
600V |
2.5 |
2.5 |
5 |
2.5 |
5 |
|
|
Utilisation category |
A |
A |
A |
A |
A |
|
|
Endurance |
Mechanical |
8500 |
8500 |
8500 |
8500 |
8500 |
|
Electrical |
1500 |
1500 |
1500 |
1500 |
1500 |
|
Part2
| Type | 2pole |
MBE-102E |
MBE-102S |
|||||
| 3pole |
MBE-103E |
MBE-103S |
MBE-203E |
MBE-203S |
MBE-403E |
MBE-403S |
||
| Frame size(AF) |
100 |
225 |
400 |
|||||
| Rated current (A) |
5,10,15, |
5,10,15, |
100,125,150,175,220,225 |
250,300,350,400 |
||||
| Rated operational voltage(V) Ue (50/60Hz) |
600 |
600 |
600 |
600 |
600 |
600 |
||
| Rated insulation voltage(V) Ui (50/60Hz) |
690 |
690 |
690 |
690 |
690 |
690 |
||
| Rated impulse withstand voltage (KV) Uimp |
6 |
6 |
6 |
6 |
6 |
6 |
||
| Ultimate breaking capacity (KA, Icu, AC 50/60Hz) |
220/240V |
10 |
50 |
35 |
50 |
35 |
50 |
|
| 380V |
7.5/5 |
25 |
18 |
25 |
30 |
42 |
||
| 415V |
7.5/5 |
25 |
18 |
25 |
25 |
35 |
||
| 440/460V |
5 |
25 |
18 |
25 |
25 |
35 |
||
| 480/500V |
2.5 |
25 |
10 |
14 |
18 |
25 |
||
| 600V |
2.5 |
14 |
7.5 |
10 |
18 |
22 |
||
| Utilisation category |
A |
A |
A |
A |
A |
A |
||
| Endurance | Mechanical |
8500 |
8500 |
7000 |
7000 |
4000 |
400 |
|
| Electrical |
1500 |
1500 |
1000 |
1000 |
1000 |
1000 |
||
Dimension:
Meba LS ABE 225A MCCB Circuit Breaker MBE 203B is delevop moulded case circuit breaker used to distribute electric energy in distribution network, overload or short circuit protection power equipment and transformation of infrequent circuit under the normal conditions.
1. MBE series MCCB is developed from LS type, suitable for industrial or commercial power and lighting with AC50/60Hz, rated working voltage up to AC600V/DC250V, rated current up to 630A.
2. It’S a kind of economical breaker with the characters of stable and reliable function, beautiful appearance, small size and long life.
3. It can be used for conversion of line and infrequent starting motor. It can also be attached to install the accessories which have protection function for avoiding loss-voltage, undervoltage.
4. The product can install connection line with front board and back board, it also can equip hand-operating apparatus or motor-operating apparatus to control in a remote distance.
The rated insulation voltage for this series of circuit breaker is 690V, the rated operating voltage is 600V, the rated frequency is 50Hz, the other rated values for the main circuit.
|
Type |
2pole |
MBE-32E |
MBE-52E |
MBE-52S |
MBE-62E |
MBE-62S |
|
3pole |
MBE-33S |
MBE-53E |
MBE-53S |
MBE-63E |
MBE-63S |
|
|
Frame size(AF) |
30 |
50 |
60 |
|||
|
Rated current (A) |
5,10,15, |
5,10,15,20 |
60 |
|||
|
Rated operational voltage(V) Ue (50/60Hz) |
600 |
600 |
600 |
600 |
600 |
|
|
Rated insulation voltage(V) Ui (50/60Hz) |
690 |
690 |
690 |
690 |
690 |
|
|
Rated impulse withstand voltage (KV) Uimp |
6 |
6 |
6 |
6 |
6 |
|
|
Ultimate breaking capacity |
220/240V |
10 |
10 |
25 |
10 |
25 |
|
380V |
7.5/5 |
7.5/5 |
14/10 |
7.5/5 |
14/10 |
|
|
415V |
7.5/5 |
7.5/5 |
14/10 |
7.5/5 |
14/10 |
|
|
440/460V |
5 |
5 |
10 |
5 |
10 |
|
|
480/500V |
2.5 |
2.5 |
7.5 |
2.5 |
7.5 |
|
|
600V |
2.5 |
2.5 |
5 |
2.5 |
5 |
|
|
Utilisation category |
A |
A |
A |
A |
A |
|
|
Endurance |
Mechanical |
8500 |
8500 |
8500 |
8500 |
8500 |
|
Electrical |
1500 |
1500 |
1500 |
1500 |
1500 |
|
Part2
| Type | 2pole |
MBE-102E |
MBE-102S |
|||||
| 3pole |
MBE-103E |
MBE-103S |
MBE-203E |
MBE-203S |
MBE-403E |
MBE-403S |
||
| Frame size(AF) |
100 |
225 |
400 |
|||||
| Rated current (A) |
5,10,15, |
5,10,15, |
100,125,150,175,220,225 |
250,300,350,400 |
||||
| Rated operational voltage(V) Ue (50/60Hz) |
600 |
600 |
600 |
600 |
600 |
600 |
||
| Rated insulation voltage(V) Ui (50/60Hz) |
690 |
690 |
690 |
690 |
690 |
690 |
||
| Rated impulse withstand voltage (KV) Uimp |
6 |
6 |
6 |
6 |
6 |
6 |
||
| Ultimate breaking capacity (KA, Icu, AC 50/60Hz) |
220/240V |
10 |
50 |
35 |
50 |
35 |
50 |
|
| 380V |
7.5/5 |
25 |
18 |
25 |
30 |
42 |
||
| 415V |
7.5/5 |
25 |
18 |
25 |
25 |
35 |
||
| 440/460V |
5 |
25 |
18 |
25 |
25 |
35 |
||
| 480/500V |
2.5 |
25 |
10 |
14 |
18 |
25 |
||
| 600V |
2.5 |
14 |
7.5 |
10 |
18 |
22 |
||
| Utilisation category |
A |
A |
A |
A |
A |
A |
||
| Endurance | Mechanical |
8500 |
8500 |
7000 |
7000 |
4000 |
400 |
|
| Electrical |
1500 |
1500 |
1000 |
1000 |
1000 |
1000 |
||
Dimension:
Meba ABE ABS moulded case circuit breaker MBE52B is delevop moulded case circuit breaker used to distribute electric energy in distribution network, overload or short circuit protection power equipment and transformation of infrequent circuit under the normal conditions.
Meba plugs and connectors MN3302
Meba industrial sockets MN3312
Meba industrial sockets MB1808
Meba industrial power socket MN3321
Meba industrial power socket MN3321
Meba industrial power socket MB1809
Meba industrial power socket MB1809
Meba industrial plugs and sockets-MN1332
Meba industrial plugs and sockets-MN1332
RCBO MBR2210C from Meba
General
1.1Function
Personnel and fire protection
Cable and line protection against overload and short-circuits.
1.2 Selection
I∆n ≤ 30 mA: additional protection
In the case of direct contact.
I∆n ≤ 300 mA: preventative fire protection
In the case of ground fault currents.
AC class – Tripping is ensured for sinusoidal,
Alternating currents, whether they be quickly applied or slowly increase.
1.3 Performance & Usage
Circuit breaker is mainly suitable for overload and short protection. It is especially used for illumination and distribution. It is of pleasing out-look, light weight, reliable performance, high breaking capacity, quick trip. etc.
|
Standard |
IEC60898 |
|
Type(wave form of the earth leakage sensed) |
AC |
|
Thermo-magnetic release characteristic |
8-12In |
|
Number of poles |
2P |
|
Rated current(In) |
6, 10, 16, 20, 25, 32, 40A |
|
Rated sensitivity I∆n |
0.03, 0.1, 0.3A |
|
Rated residual making and breaking capacity I∆n |
2000A |
|
Rated short-circuit capacity Icn |
6000A |
|
Break time under I∆n |
≤0.1S |
|
Rated frequency |
50Hz |
|
Rated impulse withstand voltage(1.2/50) Uimp |
4000V |
|
Dielectric TEST voltage, Freq for 1min |
2.0Kv |
|
Insulated voltage UI |
500V |
|
Pollution degree |
3 |
|
Electrical life |
1500 |
|
Mechanical life |
8500 |
|
Contact position indicator |
Yes |
|
Protection degree |
IP20 |
|
Ambient temperature (with daily average≤35℃) |
-5~+40℃ |
|
Storage temperature |
-25~+70℃ |
|
Terminal connection type |
Cable/Pin-type busbar |
|
Terminal size top/bottom for cable |
16~50mm² |
|
6-1/10AWG |
|
|
Terminal size top/bottom for busbar |
16~35mm² |
|
6-2AWG |
|
|
Tightening torque |
3.5 N*m |
|
31 In-Ibs |
|
|
Mounting connection |
On din rail EN60715(35mm) by means of fast dip device from top |
Meba Electrical RCBO MBR2210C frame and parts adopt plastic of high inflammable resistance and shock resistance for long service life. It is mainly used for overload and short circuit protection.
Meba industrial plugs and connectors-MN3301
Meba industrial plugs and connectors-MN3301
Protection against the effects of earth leakage, overload and short circuit currents.
■ 2 pole switching of phase & neutral. Phase protected against overloads and short circuits
■ Commercial, industrial and domestic electrical distribution systems
Note: must not be used as the sole means of providing protection against direct contact.
Application:
1. C65NLE RCBO is used for the protection against electrical leakage in the circuit of 50Hz or 60Hz, rated voltage single-phase 230V, 3 phase 400V, rated current up to 60A.
2. When somebody gets an electric shock or the residual current of the circuit exceeds the fixed value, the ELCB can cut off the power within the time.
3. It is automatically to protect the personal safety and preventing the equipment from the fault resulted by the residual current.
4. With this function, the ELCB can protect the circuit against overload and short circuit or can be used for the unfrequent switchover of the circuit under normal conditions.
5. It conforms to IEC61009 standard.
Performance & Usage
Circuit breaker is mainly suitable for overload and short protection. It is especially used for illumination and distribution. It is of pleasing out-look, light weight, reliable performance, high breaking capacity, quick trip. etc.
|
Rated Current |
6, 10, 16, 20, 25, 32, 40A |
|
Circuit breaker application |
Distribution |
|
Range of product |
C60 |
|
Product or component type |
Earth leakage circuit breaker |
|
Device short name |
C60 RCBO |
|
Poles description |
1P + N |
|
Neutral position |
Right |
|
[In] rated current |
20 A ( 30 °C ) |
|
Network type |
AC |
|
Trip unit technology |
Thermal-magnetic |
|
Curve code |
C |
|
Earth-leakage sensitivity |
100 mA |
|
Earth-leakage protection time delay |
Instantaneous |
|
Mounting support |
35 mm symmetrical DIN rail |
|
Working Frequency |
50/60 Hz |
■ Nominal voltage: 110/240V
■ Breaking capacity: 6000A Ics to BS EN 60898, and earth leakage tested to BS EN 61009
■ Tripping characteristics: C curve: the magnetic release operates between 5 and 10 In
■ Positive contact indication of the phase
conductor: in accordance with the IEE Wiring Regulations BS7671
■ Sensitivity: (non-adjustable) 30mA:
unwanted tripping: The DPN rcbo incorporates a filtering device, preventing the risks of unwanted tripping due to transient voltages (lightning, line disturbances on other equipment and transient currents from high capacitive circuits)
■ Visual indication of trip due to earth faults
■ AC Class
■ Cable capacities: Tunnel terminals up to 16mm2
■ Weight: 190g
■ Installation: Panel mounting on symmetrical DIN rail in multi-service type boards and standard
enclosures
■ Padlocking in the ON/OFF position by using
Comb busbars:
Comb busbars enable several circuit breakers to be supplied with power.
■ The supply to the comb busbar can be connected:
■ Directly across the circuit breaker terminals by a
16mm2 cable
OR
■ Via 25mm2 connectors. Suitable for use with DPN MCBs and DPN vigi or combinations of both
Characteristics:
■ Current rating at 400C:
■ 100A with a central connector
■ 125A with two supply points
Clip-on markers
■ Markers can be installed:
■ On the front face (max. 6 markers) Or above the downstream terminals (max. 4markers).
Meba Meba C60 DPN RCBO Combined MCB RCD MBR116C frame and parts adopt plastic of high inflammable resistance and shock resistance for long service life. It is mainly used for overload and short circuit protection.
Meba industrial plugs and receptacles MN1342
Meba industrial plugs and receptacles MN1342
Meba industrial plug MN6301
Meba industrial plug MB1810
Application:
1. This is belong to DZ47L C45L RCBO is used for the protection against electrical leakage in the circuit of 50Hz or 60Hz, rated voltage 1 phase 230V and 3 phase 400V, rated current up to 63A.
2. When somebody gets an electric shock or the residual current of the circuit exceeds the fixed value, the ELCB can cut off the power within the time.
3. It is automatically to protect the personal safety and preventing the equipment from the fault resulted by the residual current.
4. With this function, the ELCB can protect the circuit against overload and short circuit or can be used for the unfrequent switchover of the circuit under normal conditions.
5. It conforms to IEC61009 standard.
Normal Operation and Mounting Requirement:
◆Circumstance temperature -5~+40, average temperature not exceeding 35.
◆Altitude above sea level less than 2000m.
◆Humidity not exceeding 50% at 40 and not exceeding 90% at 25.
◆Installation class II or III.
◆Pollution class II.
◆Installation method DIN Rail mounting type.
◆The external magnetism shall not be more than 5 times of terrestrial one.
◆Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position.
Performance & Usage
Circuit breaker is mainly suitable for overload and short protection. It is especially used for illumination and distribution. It is of pleasing out-look, light weight, reliable performance, high breaking capacity, quick trip. etc.
|
Standard |
lEC/EN61009-1 |
|
Poles |
1P+N,2P,3P,3P+N,4P |
|
Type(wave form of the earth leakage sensed) |
AC |
|
Thermo-magnetic release characteristic |
C,D |
|
Rated sensitivity lΔn |
0.03A,0.05A,0.1A,0.3A |
|
Rated residual making and breaking capacity lΔm |
500(ln<63A)630(ln=63A) |
|
Rated short-circuit capacity lcn |
3000/4500A |
|
Break time under lΔn |
≤0.1s |
|
Rated impulse withstand voltage(1.2/50)Uimp |
4000V |
|
Dielectric test voltage at ind.Freq.for 1min |
2KV |
|
lnsulation voltage Ui |
500V |
|
Electrical life |
2000t |
|
Mechanical life |
2000t |
|
Contact position indicator |
Yes |
|
Protection degree |
lP20 |
|
Ambient temperature(with daily average≤35°c) |
-5~+40°c |
|
Storage temperature |
-25~+70°c |
|
Terminal connection type |
Cable/Pin-type busbar |
|
Terminal size top/bottom for cable |
25mm² 18-3AWG |
|
Terminal size top/bottom for busbar |
25mm² 18-3AWG |
|
Tightening torque |
2N*m 18ln-lbsm |
|
Mounting |
On DIN rail EN 60715(35mm)by means of fast clip device |
Product Purpose:
1.Personnal and fire protection cable and line protection against overload and short-circuits
2,General rules for choosing RCBO:
A. Rated residual operating current
lΔn≤30mA:additional protection in the case of direct contact
lΔn≤300mA:preventative fire protection in the case of ground fault currents
B. Tripping class
Operation Principle:
Meba Earth Leakage Circuit Breakers MBR416C frame and parts adopt plastic of high inflammable resistance and shock resistance for long service life. It is mainly used for overload and short circuit protection.
Meba electric sockets MN6321
Application:
1. C65NLE RCBO is used for the protection against electrical leakage in the circuit of 50Hz or 60Hz, rated voltage single-phase 230V, 3 phase 400V, rated current up to 60A.
2. When somebody gets an electric shock or the residual current of the circuit exceeds the fixed value, the ELCB can cut off the power within the time.
3. It is automatically to protect the personal safety and preventing the equipment from the fault resulted by the residual current.
4. With this function, the ELCB can protect the circuit against overload and short circuit or can be used for the unfrequent switchover of the circuit under normal conditions.
5. It conforms to IEC61009 standard.
Performance & Usage
Circuit breaker is mainly suitable for overload and short protection. It is especially used for illumination and distribution. It is of pleasing out-look, light weight, reliable performance, high breaking capacity, quick trip. etc.
|
Frame class |
1–60A |
|
Rated working voltage |
240/415V |
|
Rated frequency |
50/60Hz |
|
Rated working current |
16202532405063A |
|
Rated residual operating current |
0.03,0.1,0.3,0.5A |
|
Rated residual un-operating current |
0.015,0.05,0.15,0.25A |
|
Sensibility |
A TypeAC Type |
|
Maximum operating time |
In t≤0.1s , 5In t≤0.04 |
|
Rated making and breaking capacity |
In≤50A 500A,In=63A 630A , In63A 1500A |
|
Limiting value of un-operating current |
6In |
|
Rated limiting short-circuit current |
3000A |
|
Pole number |
1/2/3/4P |
|
Mechanical life |
8000 |
|
Electric life |
4000 |
Basic Data:
|
Constrcution and Feature |
|
1)Protection against both overload and short circuit |
|
2)High short-circuit capacity |
|
3)Applicable to terminal and pin/fork type busbar connection |
|
4)Easy mounting onto 35mm DIN rail |
|
Technical Data |
|
4)Pole No.: 1 . 1P+N .2 . 3 . 3P+N . 4 / 30mA |
|
5)Rated Voltage : AC 230/400V~ |
|
6)Rated Current(A): 1,2,3,4,6,10,13,16,20,25,32,40,50,63 |
|
7)Tripping curve: B, C, D |
|
8)Rated short-circuit capacity(Icn): 6KA |
|
9)Rated frequency :50Hz/60Hz |
|
10)Enerygy limiting class : 3 |
|
11)Rated impulse withstand voltage: 6.2kV |
|
12)Electro-mechanical endurance : 4000 |
|
13)Connection terminal : srew terminal and pillar terminal with clamp |
|
14)Connection capacity : Rigid conductor up to 25mm2 |
|
15)Fastenning torque: 2.0Nm |
|
16)Installation: On symmetrical DIN rail 35mm /Panel Mounting |
|
17)Terminal Connection Height: 19mm |
Meba C65 2P function earth leakage circuit breaker MBR126C frame and parts adopt plastic of high inflammable resistance and shock resistance for long service life. It is mainly used for overload and short circuit protection.
Application:
1. C65NLE RCBO is used for the protection against electrical leakage in the circuit of 50Hz or 60Hz, rated voltage single-phase 230V, 3 phase 400V, rated current up to 60A.
2. When somebody gets an electric shock or the residual current of the circuit exceeds the fixed value, the ELCB can cut off the power within the time.
3. It is automatically to protect the personal safety and preventing the equipment from the fault resulted by the residual current.
4. With this function, the ELCB can protect the circuit against overload and short circuit or can be used for the unfrequent switchover of the circuit under normal conditions.
5. It conforms to IEC61009 standard.
Performance & Usage
Circuit breaker is mainly suitable for overload and short protection. It is especially used for illumination and distribution. It is of pleasing out-look, light weight, reliable performance, high breaking capacity, quick trip. etc.
|
Frame class |
1–60A |
|
Rated working voltage |
240/415V |
|
Rated frequency |
50/60Hz |
|
Rated working current |
16202532405063A |
|
Rated residual operating current |
0.03,0.1,0.3,0.5A |
|
Rated residual un-operating current |
0.015,0.05,0.15,0.25A |
|
Sensibility |
A TypeAC Type |
|
Maximum operating time |
In t≤0.1s , 5In t≤0.04 |
|
Rated making and breaking capacity |
In≤50A 500A,In=63A 630A , In63A 1500A |
|
Limiting value of un-operating current |
6In |
|
Rated limiting short-circuit current |
3000A |
|
Pole number |
1/2/3/4P |
|
Mechanical life |
8000 |
|
Electric life |
4000 |
Basic Data:
|
Constrcution and Feature |
|
1)Protection against both overload and short circuit |
|
2)High short-circuit capacity |
|
3)Applicable to terminal and pin/fork type busbar connection |
|
4)Easy mounting onto 35mm DIN rail |
|
Technical Data |
|
4)Pole No.: 1 . 1P+N .2 . 3 . 3P+N . 4 / 30mA |
|
5)Rated Voltage : AC 230/400V~ |
|
6)Rated Current(A): 1,2,3,4,6,10,13,16,20,25,32,40,50,63 |
|
7)Tripping curve: B, C, D |
|
8)Rated short-circuit capacity(Icn): 6KA |
|
9)Rated frequency :50Hz/60Hz |
|
10)Enerygy limiting class : 3 |
|
11)Rated impulse withstand voltage: 6.2kV |
|
12)Electro-mechanical endurance : 4000 |
|
13)Connection terminal : srew terminal and pillar terminal with clamp |
|
14)Connection capacity : Rigid conductor up to 25mm2 |
|
15)Fastenning torque: 2.0Nm |
|
16)Installation: On symmetrical DIN rail 35mm /Panel Mounting |
|
17)Terminal Connection Height: 19mm |
Meba c65 elcb rcbo rccb earth leakage circuit breaker MBR136C frame and parts adopt plastic of high inflammable resistance and shock resistance for long service life. It is mainly used for overload and short circuit protection.
Application
Meba electronic current relay switches MBTH-22 series thermal realy is suitable for using in power system with AC 50HZ,rated operation voltage up to 660A and 1000V,in main circuit,current from 0.1A to 630A.It is used to protect AC threephase asynchronous motor against overload and open-phase.The realys have the best push-button for breaking NC contacts and the operating indication and free trip characteristics.The products also can be supplied with protecting case to ensure safety .The products can be plug and install independently or mount by rail.
Technical Data