Categories
Universal Sockets

Meba electric outlet MS-5P-2035

Meba electric outlet MS-5P-2035

1. Shell: Aluminum alloy
2. Protection:
2. Control: Multi-function anti-lighting and anti-surge device
4. Certification: CE, RoHS
5. Export Markets: Gobal
6. Productioin Capacity: 200, 000/Year
7. Packing: Carton with PE

Meba electric light socket MS-5P-2015

Technical Parameter:

Model No: MS 5P /2035

Rated Voltage : 250 VAC

Rated Frequency : 50/60 Hz

Rated Current: 16 A

Surrounding Temperature : -10 To + 60 C

Humidity : 60 % At + 40 C

Overload Breaking Capacity : 16 A

Standard: UL817, CSA 22.2 , CEE7 V11

Packing way: Standard export carton box

Certificate: CE

Categories
Universal Sockets

Meba electric light socket MS-5P-2015

Meba electric light socket MS-5P-2015

1. Shell: Aluminum alloy
2. Protection:
2. Control: Multi-function anti-lighting and anti-surge device
4. Certification: CE, RoHS
5. Export Markets: Gobal
6. Productioin Capacity: 200, 000/Year
7. Packing: Carton with PE

Meba electric light socket MS-5P-2015

Technical Parameter:

Model No: MS 5P /2015

Rated Voltage : 250 VAC

Rated Frequency : 50/60 Hz

Rated Current: 16 A

Surrounding Temperature : -10 To + 60 ℃

Humidity : 60 % At + 40 C

Overload Breaking Capacity : 16 A

Standard: UL817, CSA 22.2 , CEE7 V11

Packing way: Standard export carton box

Certificate: CE

Categories
C Series Moulded Case Circuit Breaker

Meba Low Voltage Moulded case circuit breaker HMDLB65k

·Brief description
1. Compared with traditional circuit breaker or relevant fuse,MEBA C series circuit breaker has excellent protection performance in smaller space, in maximum range can satisfy rated current and faulty current’s requirement.
2. C series  circuit breaker  can  be used in cascade system,  meet next stage circuit breaker’s limit section capacity select protection req-uirement, save whole system cost.
C series circuit breaker complies with IECZ60947-2 international standard;  also comply with main industrial countries standard.
·Features
1. C series  circuit  breaker  including 7 basic frames, frame current from  100  to  2500A.  Each  frame  has up to  415V 100KA (AC240V 200KA)short circuit breaking capacity multiple choice, more flexibility in design, and save space as well.
2. Actually, using  C series  circuit breaker  can  avoid  in  re-design system.  It  can be used in original  switchboard,  feeder ark, bus duct, equipment control panel,  motor  control  center  substitute of old type circuit  breaker.  At  most situations,  can  adopt  same Connector bar, terminal and shaft structure.
3. Circuit  breaker  stan dard  temperature  is  40  degree,  for other higher  ambient  temperature  situation,  can  use  50  degree  factory finalize type design circuit breaker.
4. C series circuit breaker can be used in DC situation as well, 630A frame  3P  circuit breaker   concatenation  used  in  DC600V  breaking capacity can reach 40KA.

·Most reasonable contact terminal system design
C series circuit breaker flexible and special specific is adopt one of the most reasonable design in circuit breaker history, can assure circuit breaker in high fault current fast and reliable breaking.

·Whole testing process in factory
Each C series circuit breaker steady and reliable quality is acc-ording to a whole testing procedure assurance, each circuit breaker’s same pole has to make two times setting test to verify trip,  operating characteristic and electric circuit contentiously.

·High breaking capacity in smaller space
C circuit breaker in shape and electric function can be interchan-ged with Westinghouse moulded case circuit breaker, this means C series circuit breaker is ideal product after  improve its equipment design.
·Operation structure
1.C  series  circuit breaker adopt in fast-separate  and  fast-close mechanical  operation,  which has free trip function,  assure  circuit breaker in short circuit time can not keep closed.
2. Circuit  breaker’s  trip shaft’s  position and two sides’  windows point its working condition:  ‘witch-on’, ‘reak- brake’ and ‘rip’ If circuit breaker overloading,  short circuit, shunt  or  under voltage or press TEST button makes trip, shaft will slip to ‘rip’ position. At mean while if need  circuit  breaker re-switch on,  it should switch shaft to reset position then break brake.

·Current limit feature
   C series circuit breaker adopts high repulsion contact terminal structure and advantage ARC technology, so it has significant currentlimit function.
·Standard
  IEC60947-1:General rule
IEC60947-2:Circuit breaker
IEC60947-3:Switch, isolating switch, load switch etc.

C Series Trip unit type work

KW-40K-Parameter

Working condition:
1.The altitude not exceeding 2000m
2.The ambient temperature is from +40°Cto -5°C
3.Ambient environment is free from explosive danger and air or dust, which may cause corrosion of metal or weakness of insulation.
4.Ambient environment is free from erosion of rain or snow.
5.Pollution degree 3
6.Over-voltage category III

C series MCCB Structure

[Download not found]Meba Low Voltage Moulded case circuit breaker HMDLB65k is big ampere circuit breaker  with high breaking capacity match with RCCB, MCB  use  to protection power distribution equipment safety.

Categories
Automatic Voltage Regulator

Meba Auto Voltage Regulator SVC-5000VA

General:

SVC single-phase and three-phase high accuracy full-automatic AC voltage stabilizer is one kind of our dominant products, made up of contact auto voltage regulator, servo motor, automatic control circuit, etc.

When the power network voltage fluctuates or the load varies, automatic sampling control circuit will send signal to drive the servo motor which can adjust the position of carbon brush of auto voltage regulator, then, the output voltage will be adjusted to rated value and get a steady state.

It has excellent features, such as elegant appearance, compact structure, light weight, small waveform distortion, high efficiency, stable and reliable performance and so on.

This product is an ideal stabilized voltage supply, widely used in any locations requiring electricity and ensures your power device can run normally.

Application:

For office equipment, test equipment, lighting systems, safety alarm systems, communication systems, medical equipment, duplicators, stereo sound equipment, industrial automatic equipment, color film developing equipment, digital control machine tools, checkout equipment, TV sets, office appliances.

Performance:

Single-phase input voltage Single phase 160V-250V
Single-phase output voltage 1. 0.5KVA~3KVA: Single -phase 220V and 110V
2. 5KVA~30KVA: Single -phase 220V
Three-phase input voltage 1. Phase voltage 160-250V
2. Wire voltage 227-430V
Three-phase output voltage 1. Phase voltage 220V
2. Wire voltage 380V
Voltage stabilizing precision 220V±3% 110V±6%
Frequency 50Hz/60Hz
Adjustable time <1s(when input voltage has a change of 10%)
Efficiency >90%
Over-voltage protection 246V±4V
Delay time Long 5min±2min, short 5s±2s
Ambient temperature -5℃ ~ +40℃
Relative humidity ≤90%
Waveform distortion No additional waveform distortion
Load power factor 0.8
Dielectric strength 1500V/1min
lnsulation resistance ≥2MΩ

 

Model and Sepc:

Spec(VA) Product size DXWXH(cm) Package size DXWXH(cm) Weight (kg) Qty
Single-phase two-wire(desk type) SVC-500 17X19X13 44X25X35 5.0 4
SVC-1000 20X22X16 50X28X40 7.0 4
SVC-1500 20X22X16 50X28X40 8.0 4
SVC-2000 26X24X19 34X32X50 14 2
SVC-3000 29X22X24 62X38X34 16 2
SVC-5000 46X24X19 54X32X27 27 1
SVC-8000 57X27X24 71X40X35 40 1
SVC-10000 57X27X24 70X40X35 41 1
Three-phase four-wire SVC-1500 40X36X17 52X48X28 18 1
SVC-3000 42X38X19 54X50X31 23 1
SVC-4500 42X38X19 54X50X31 27 1
SVC-6000 37X28X68 48X40X78 39 1
SVC-9000 35X33X78 48X45X90 48 1
SVC-15000 43X38X73 55X51X90 85 1
Single-phase two-wire(desk type) SVC-5000 29X24X40 31X29X48 28.5 1
SVC-8000 29X24X42 40X35X52 39 1
SVC-10000 29X24X42 40X35X52 40 1
SVC-15000 40X33X65 48X45X90 75 1
SVC-20000 58X35X68 68X48X90 110 1
SVC-30000 53X43X102 64X53X112 165 1
SVC-45000 79X43X129 90X65X140 200 1
SVC-60000 79X43X129 90X65X140 250 1
Three-phase four-wire SVC-20000 43X51X91 64X55X106 124 1
SVC-30000 43X51X91 64X55X106 131 1
SVC-45000 65X43X95 78X55X110 197 1
SVC-60000 77X55X100 90X67X115 260 1
SVC-80000 77X55X100 90X67X115 290 1
SVC-100000 77X55X100 90X67X115 350 1

[Download not found] SVC 5KVA Auto Voltage Regulator suit for office equipment, test equipment, medical equipment, industrial automation equipment, household lighting system, communication system, etc.

Categories
C Series Moulded Case Circuit Breaker

Meba AC Circuit Breaker LW630

·Brief description
1. Compared with traditional circuit breaker or relevant fuse,MEBA C series circuit breaker has excellent protection performance in smaller space, in maximum range can satisfy rated current and faulty current’s requirement.
2. C series  circuit breaker  can  be used in cascade system,  meet next stage circuit breaker’s limit section capacity select protection req-uirement, save whole system cost.
C series circuit breaker complies with IECZ60947-2 international standard;  also comply with main industrial countries standard.
·Features
1. C series  circuit  breaker  including 7 basic frames, frame current from  100  to  2500A.  Each  frame  has up to  415V 100KA (AC240V 200KA)short circuit breaking capacity multiple choice, more flexibility in design, and save space as well.
2. Actually, using  C series  circuit breaker  can  avoid  in  re-design system.  It  can be used in original  switchboard,  feeder ark, bus duct, equipment control panel,  motor  control  center  substitute of old type circuit  breaker.  At  most situations,  can  adopt  same Connector bar, terminal and shaft structure.
3. Circuit  breaker  stan dard  temperature  is  40  degree,  for other higher  ambient  temperature  situation,  can  use  50  degree  factory finalize type design circuit breaker.
4. C series circuit breaker can be used in DC situation as well, 630A frame  3P  circuit breaker   concatenation  used  in  DC600V  breaking capacity can reach 40KA.

·Most reasonable contact terminal system design
C series circuit breaker flexible and special specific is adopt one of the most reasonable design in circuit breaker history, can assure circuit breaker in high fault current fast and reliable breaking.

·Whole testing process in factory
Each C series circuit breaker steady and reliable quality is acc-ording to a whole testing procedure assurance, each circuit breaker’s same pole has to make two times setting test to verify trip,  operating characteristic and electric circuit contentiously.

·High breaking capacity in smaller space
C circuit breaker in shape and electric function can be interchan-ged with Westinghouse moulded case circuit breaker, this means C series circuit breaker is ideal product after  improve its equipment design.
·Operation structure
1.C  series  circuit breaker adopt in fast-separate  and  fast-close mechanical  operation,  which has free trip function,  assure  circuit breaker in short circuit time can not keep closed.
2. Circuit  breaker’s  trip shaft’s  position and two sides’  windows point its working condition:  ‘witch-on’, ‘reak- brake’ and ‘rip’ If circuit breaker overloading,  short circuit, shunt  or  under voltage or press TEST button makes trip, shaft will slip to ‘rip’ position. At mean while if need  circuit  breaker re-switch on,  it should switch shaft to reset position then break brake.

·Current limit feature
   C series circuit breaker adopts high repulsion contact terminal structure and advantage ARC technology, so it has significant currentlimit function.
·Standard
  IEC60947-1:General rule
IEC60947-2:Circuit breaker
IEC60947-3:Switch, isolating switch, load switch etc.

KW-40K-Parameter

Working condition:
1.The altitude not exceeding 2000m
2.The ambient temperature is from +40°Cto -5°C
3.Ambient environment is free from explosive danger and air or dust, which may cause corrosion of metal or weakness of insulation.
4.Ambient environment is free from erosion of rain or snow.
5.Pollution degree 3
6.Over-voltage category III

C series MCCB Structure

[Download not found]Meba AC Circuit Breaker LW630 is big ampere circuit breaker  with high breaking capacity match with RCCB, MCB  use  to protection power distribution equipment safety.

Categories
C Series Moulded Case Circuit Breaker

Meba intelligent high breaking capacity Moulded Case Circuit Breaker KW 40k

·Brief description
1. Compared with traditional circuit breaker or relevant fuse,MEBA C series circuit breaker has excellent protection performance in smaller space, in maximum range can satisfy rated current and faulty current’s requirement.
2. C series  circuit breaker  can  be used in cascade system,  meet next stage circuit breaker’s limit section capacity select protection req-uirement, save whole system cost.
C series circuit breaker complies with IECZ60947-2 international standard;  also comply with main industrial countries standard.
·Features
1. C series  circuit  breaker  including 7 basic frames, frame current from  100  to  2500A.  Each  frame  has up to  415V 100KA (AC240V 200KA)short circuit breaking capacity multiple choice, more flexibility in design, and save space as well.
2. Actually, using  C series  circuit breaker  can  avoid  in  re-design system.  It  can be used in original  switchboard,  feeder ark, bus duct, equipment control panel,  motor  control  center  substitute of old type circuit  breaker.  At  most situations,  can  adopt  same Connector bar, terminal and shaft structure.
3. Circuit  breaker  stan dard  temperature  is  40  degree,  for other higher  ambient  temperature  situation,  can  use  50  degree  factory finalize type design circuit breaker.
4. C series circuit breaker can be used in DC situation as well, 630A frame  3P  circuit breaker   concatenation  used  in  DC600V  breaking capacity can reach 40KA.

·Most reasonable contact terminal system design
C series circuit breaker flexible and special specific is adopt one of the most reasonable design in circuit breaker history, can assure circuit breaker in high fault current fast and reliable breaking.

·Whole testing process in factory
Each C series circuit breaker steady and reliable quality is acc-ording to a whole testing procedure assurance, each circuit breaker’s same pole has to make two times setting test to verify trip,  operating characteristic and electric circuit contentiously.

·High breaking capacity in smaller space
C circuit breaker in shape and electric function can be interchan-ged with Westinghouse moulded case circuit breaker, this means C series circuit breaker is ideal product after  improve its equipment design.
·Operation structure
1.C  series  circuit breaker adopt in fast-separate  and  fast-close mechanical  operation,  which has free trip function,  assure  circuit breaker in short circuit time can not keep closed.
2. Circuit  breaker’s  trip shaft’s  position and two sides’  windows point its working condition:  ‘witch-on’, ‘reak- brake’ and ‘rip’ If circuit breaker overloading,  short circuit, shunt  or  under voltage or press TEST button makes trip, shaft will slip to ‘rip’ position. At mean while if need  circuit  breaker re-switch on,  it should switch shaft to reset position then break brake.

·Current limit feature
   C series circuit breaker adopts high repulsion contact terminal structure and advantage ARC technology, so it has significant currentlimit function.
·Standard
  IEC60947-1:General rule
IEC60947-2:Circuit breaker
IEC60947-3:Switch, isolating switch, load switch etc.

KW-40K-Parameter

Working condition:
1.The altitude not exceeding 2000m
2.The ambient temperature is from +40°Cto -5°C
3.Ambient environment is free from explosive danger and air or dust, which may cause corrosion of metal or weakness of insulation.
4.Ambient environment is free from erosion of rain or snow.
5.Pollution degree 3
6.Over-voltage category III

C series MCCB Structure

[Download not found]Meba intelligent high breaking capacity Moulded Case Circuit Breaker KW 40k is big ampere circuit breaker  with high breaking capacity match with RCCB, MCB  use  to protection power distribution equipment safety.

Categories
Universal Sockets

Meba electrical socket MS2015

Meba electrical socket MS2015 

1. Shell: Aluminum alloy
2. Protection:
2. Control: Multi-function anti-lighting and anti-surge device
4. Certification: CE, RoHS
5. Export Markets: Gobal
6. Productioin Capacity: 200, 000/Year
7. Packing: Carton with PE

Meba electrical socket MS2015

Technical Parameter:

Model No: MS 3P /2015

Rated Voltage : 250 VAC

Rated Frequency : 50/60 Hz

Rated Current: 16 A

Surrounding Temperature : -10 To + 60 C

Humidity : 60 % At + 40 C

Overload Breaking Capacity : 16 A

Standard: UL817, CSA 22.2 , CEE7 V11

Packing way: Standard export carton box

Certificate: CE

Categories
Cam Switch

Meba-rotary cam switches-MC1001

Categories
C Series Moulded Case Circuit Breaker

Meba Moulded Case Circuit Breaker MCCB JW 40K

·Brief description
1. Compared with traditional circuit breaker or relevant fuse,MEBA C series circuit breaker has excellent protection performance in smaller space, in maximum range can satisfy rated current and faulty current’s requirement.
2. C series  circuit breaker  can  be used in cascade system,  meet next stage circuit breaker’s limit section capacity select protection req-uirement, save whole system cost.
C series circuit breaker complies with IECZ60947-2 international standard;  also comply with main industrial countries standard.
·Features
1. C series  circuit  breaker  including 7 basic frames, frame current from  100  to  2500A.  Each  frame  has up to  415V 100KA (AC240V 200KA)short circuit breaking capacity multiple choice, more flexibility in design, and save space as well.
2. Actually, using  C series  circuit breaker  can  avoid  in  re-design system.  It  can be used in original  switchboard,  feeder ark, bus duct, equipment control panel,  motor  control  center  substitute of old type circuit  breaker.  At  most situations,  can  adopt  same Connector bar, terminal and shaft structure.
3. Circuit  breaker  stan dard  temperature  is  40  degree,  for other higher  ambient  temperature  situation,  can  use  50  degree  factory finalize type design circuit breaker.
4. C series circuit breaker can be used in DC situation as well, 630A frame  3P  circuit breaker   concatenation  used  in  DC600V  breaking capacity can reach 40KA.

·Most reasonable contact terminal system design
C series circuit breaker flexible and special specific is adopt one of the most reasonable design in circuit breaker history, can assure circuit breaker in high fault current fast and reliable breaking.

·Whole testing process in factory
Each C series circuit breaker steady and reliable quality is acc-ording to a whole testing procedure assurance, each circuit breaker’s same pole has to make two times setting test to verify trip,  operating characteristic and electric circuit contentiously.

·High breaking capacity in smaller space
C circuit breaker in shape and electric function can be interchan-ged with Westinghouse moulded case circuit breaker, this means C series circuit breaker is ideal product after  improve its equipment design.
·Operation structure
1.C  series  circuit breaker adopt in fast-separate  and  fast-close mechanical  operation,  which has free trip function,  assure  circuit breaker in short circuit time can not keep closed.
2. Circuit  breaker’s  trip shaft’s  position and two sides’  windows point its working condition:  ‘witch-on’, ‘reak- brake’ and ‘rip’ If circuit breaker overloading,  short circuit, shunt  or  under voltage or press TEST button makes trip, shaft will slip to ‘rip’ position. At mean while if need  circuit  breaker re-switch on,  it should switch shaft to reset position then break brake.

·Current limit feature
   C series circuit breaker adopts high repulsion contact terminal structure and advantage ARC technology, so it has significant currentlimit function.
·Standard
  IEC60947-1:General rule
IEC60947-2:Circuit breaker
IEC60947-3:Switch, isolating switch, load switch etc.

C Series Trip unit type work

GWF 125 parameter

Working condition:
1.The altitude not exceeding 2000m
2.The ambient temperature is from +40°Cto -5°C
3.Ambient environment is free from explosive danger and air or dust, which may cause corrosion of metal or weakness of insulation.
4.Ambient environment is free from erosion of rain or snow.
5.Pollution degree 3
6.Over-voltage category III

C series MCCB Structure

[Download not found]Meba Moulded Case Circuit Breaker MCCB JW 40K  is big ampere circuit breaker  with high breaking capacity match with RCCB, MCB  use  to protection power distribution equipment safety.

Categories
Cam Switch

Meba-changeover switch-MC6317

Installed in equipments,which requires a key to lock the switch. It prevents the mis-operation of the equipments from the unthorised personnel;

[Download not found]
Categories
C Series Moulded Case Circuit Breaker

Meba 3P 225A Moulded Case Breakers FWF 225

·Brief description
1. Compared with traditional circuit breaker or relevant fuse,MEBA C series circuit breaker has excellent protection performance in smaller space, in maximum range can satisfy rated current and faulty current’s requirement.
2. C series  circuit breaker  can  be used in cascade system,  meet next stage circuit breaker’s limit section capacity select protection req-uirement, save whole system cost.
C series circuit breaker complies with IECZ60947-2 international standard;  also comply with main industrial countries standard.
·Features
1. C series  circuit  breaker  including 7 basic frames, frame current from  100  to  2500A.  Each  frame  has up to  415V 100KA (AC240V 200KA)short circuit breaking capacity multiple choice, more flexibility in design, and save space as well.
2. Actually, using  C series  circuit breaker  can  avoid  in  re-design system.  It  can be used in original  switchboard,  feeder ark, bus duct, equipment control panel,  motor  control  center  substitute of old type circuit  breaker.  At  most situations,  can  adopt  same Connector bar, terminal and shaft structure.
3. Circuit  breaker  stan dard  temperature  is  40  degree,  for other higher  ambient  temperature  situation,  can  use  50  degree  factory finalize type design circuit breaker.
4. C series circuit breaker can be used in DC situation as well, 630A frame  3P  circuit breaker   concatenation  used  in  DC600V  breaking capacity can reach 40KA.

·Most reasonable contact terminal system design
C series circuit breaker flexible and special specific is adopt one of the most reasonable design in circuit breaker history, can assure circuit breaker in high fault current fast and reliable breaking.

·Whole testing process in factory
Each C series circuit breaker steady and reliable quality is acc-ording to a whole testing procedure assurance, each circuit breaker’s same pole has to make two times setting test to verify trip,  operating characteristic and electric circuit contentiously.

·High breaking capacity in smaller space
C circuit breaker in shape and electric function can be interchan-ged with Westinghouse moulded case circuit breaker, this means C series circuit breaker is ideal product after  improve its equipment design.
·Operation structure
1.C  series  circuit breaker adopt in fast-separate  and  fast-close mechanical  operation,  which has free trip function,  assure  circuit breaker in short circuit time can not keep closed.
2. Circuit  breaker’s  trip shaft’s  position and two sides’  windows point its working condition:  ‘witch-on’, ‘reak- brake’ and ‘rip’ If circuit breaker overloading,  short circuit, shunt  or  under voltage or press TEST button makes trip, shaft will slip to ‘rip’ position. At mean while if need  circuit  breaker re-switch on,  it should switch shaft to reset position then break brake.

·Current limit feature
   C series circuit breaker adopts high repulsion contact terminal structure and advantage ARC technology, so it has significant currentlimit function.
·Standard
  IEC60947-1:General rule
IEC60947-2:Circuit breaker
IEC60947-3:Switch, isolating switch, load switch etc.

C Series Trip unit type work

GWF 125 parameter

Working condition:
1.The altitude not exceeding 2000m
2.The ambient temperature is from +40°Cto -5°C
3.Ambient environment is free from explosive danger and air or dust, which may cause corrosion of metal or weakness of insulation.
4.Ambient environment is free from erosion of rain or snow.
5.Pollution degree 3
6.Over-voltage category III

C series MCCB Structure

[Download not found]Meba 3P 225A Moulded Case Breakers FWF 225 is big ampere circuit breaker  with high breaking capacity match with RCCB, MCB  use  to protection power distribution equipment safety. 

Categories
Cam Switch

Meba-cam switch-MB3018

Type CA10-20 CA10-25 CA10-32 CA10-75 CA10-125
Rated Insulation Voltage Ui(V) 660 660 660 660 660
Conventional Heating Current Ith(A) AC10≤40 20 25 32 75 125
Rated Working Voltage Ue(V) 120 240 440 120 240 440 120 240 440 120 440 440
Rated Working Current Ie(A) AC-21A AC-22A 20 25 32 63 125
AC-23A 15 22 30 57 90
AC-2 15 22 30 57 90
AC-3 11 15 22 36 36
AC-4 3.5 6.5 11 15 30
AC-15 5 4 8 5 14 6
AC-13 5 1 9 1.5 25 11 60
Rated Control Power (KW) AC-23A 7.5 11 15 30 45
AC-2 7.5 11 15 30 45
AC-3 5.5/3 7.5/3.7 11 24 45
AC-4 1.5 3/2.2 5.5 11.5 18.5
Mechanical Life 60X104
Electrical Life AC-15 20X104 DC-12 6X104
[Download not found]
Categories
Socket Mounted KWH Meters

Meba-Electromechanical Socket Power Meter-MB351PB

Application

 Meba electromechanical socket power meter MB351PB  is a kind of new style single phase three wire active energy meter, it adopt micro-electronics technique, and imported large scale integrate circuit, use advanced technique of digital and SMT techniques, etc. The meter completely accord with relevant technical requirements of class 1 single phase active energy meter stipulated in international standard IEC 62053-21 and standard ANSI C12.10-1997. It can accurate and directly measure 50Hz or 60Hz active energy consumption from three phase AC electricity net, it is use for setting indoor or outdoor meter box. This meter has 7 digits LCD displays shows power. And there is far infrared communication module in it, can read the meter and set the system parameters conveniently, it has following features: good reliability, light weight, specious nice appearance, convenient installation, etc.

Technical Data

Model Accuracy Reference Voltage(V) Current specifications(A) Starting current(A) Insulation performance
MB351PB Class 1 240 15(100) 0.06 AC voltage 4kv for 1 minute,
1.2/50us waveform
pulse voltage 6kv

Installing Diagram

Dimension for MB351PB
Dimension for MB351PB

 

 

 

 

 

Wiring diagram for MB351PB
Wiring diagram for MB351PB

1. Socket installed, the cover is made of PC material which is transparent and anti-UV molded overall, the terminal is made of black glass fiber which can fire-retardant and enhanced PC material. It has following features: Good weatherability, anti-impact, specious appearance, etc. complying with standard ANSI C12.10-1997.
2. 8 digits LCD display, may select 6+2 digits display (999999.91kWh, default) or 7+1 digits display, can be set by the port of far infrared communication by users.
3. There is a port of far infrared pulse output, use for checking conveniently.
4. There is a port of far infrared state communication, standard configuration communication agreement complying with standard DL/T645-1997, may select other configuration communication agreement.
5. LED instructions signal of energy impulse (red).
6. Automatic detection of the flow of load current, and display on LCD (when display, that is meaning the direction of the flow of load current reverse).
7. Single direction single component measure single phase three wire active energy consumption. It is nothing with direction of the flow of load current. Complying with standard IEC 62053-21.
8. Directly connect operation, type 2S wiring, may select single phase two wire, Directly connect operation, type 1S wiring (Product Configuration code is PA).

[Download not found]
Categories
Socket Mounted KWH Meters

Meba-Socket Controlled Meters-MB352

Application

Meba socket controlled meters MB352 is a kind of new style portable socket installed single phase two wire active energy meter, it adopt micro-electronics technique, and imported large scale integrate circuit, use advanced technique of digital and SMT techniques, etc. It is use for the people who hope power monitor to house appliance. The meter completely accord with relevant technical requirements of class 2 single phase active energy meter stipulated in international standard IEC 62053-21. It can accurate and directly measure 50Hz or 60Hz active energy consumption from single phase AC electricity net, it can display total energy consumption by step motor type impulse register. It has following features: good reliability, small volume, light weight, specious nice appearance, convenient installation, etc.

Technical Data

Model Accuracy Reference Voltage(V) Current specifications(A) Starting current(A) Insulation performance
MB352 Class 2 127
230
3(16) 0.015 AC voltage 4kv for 1 minute,
1.2/50us waveform
pulse voltage 6kv

Installing Diagram

Dimension for MB352
Dimension for MB352

 

 

 

 

 

 

 

Wiring diagram for MB352
Wiring diagram for MB352

1. Portable socket installed, the cover, the bottom of the meter, and the terminal are made of flame-retardant glass fiber make strong of PC material with transparent glass window which made of PC material, it has following features: anti-impact, specious appearance, etc.
2. Plug and socket can turn right 90, and make installation and using conveniently.
3. The plug can fit for all kinds of socket in Europe. There are two kinds of sockets you can choose, two-hole a circular type grounding needle (Product Configuration code is ZA) and two-hole and two grounding strip (Product Configuration code is ZB).
4. 5+1 digits display (99999.1kWh) by step motor type impulse register.
5. Two LED instructions power supply state (green) and signal of energy impulse (red).
6. Standard configuration don’t detection direction of the flow of load current. May select automatic detection the direction of the flow of load current. And instructions (Only red energy pulse signal when working, that is meaning the direction of the flow of load current reverse).
7. Single direction measure single phase two wire active energy consumption. It is nothing with direction of the flow of load current. Complying with standard IEC 62053-21.
8. Directly connect operation, type 1C wiring.

Categories
Socket Mounted KWH Meters

Meba-Energy Smart Socket Meters-MB352-1

Application

Meba energy smart socket meters MB352  is a kind of new style portable socket installed single phase two wire active energy meter, it adopt micro-electronics technique, and imported large scale integrate circuit, use advanced technique of digital and SMT techniques, etc. It is use for the people who hope power monitor to house appliance. The meter completely accord with relevant technical requirements of class 2 single phase active energy meter stipulated in international standard IEC 62053-21. It can accurate and directly measure 50Hz or 60Hz active energy consumption from single phase AC electricity net, it can display total energy consumption by step motor type impulse register. It has following features: good reliability, small volume, light weight, specious nice appearance, convenient installation, etc.

Technical Data

Model Accuracy Reference Voltage(V) Current specifications(A) Starting current(A) Insulation performance
MB352 Class 2 127
230
3(16) 0.015 AC voltage 4kv for 1 minute,
1.2/50us waveform
pulse voltage 6kv

Installing Diagram

Dimension for MB352
Dimension for MB352

 

 

 

 

 

 

 

 

Wiring diagram for MB352
Wiring diagram for MB352

1. Portable socket installed, the cover, the bottom of the meter, and the terminal are made of flame-retardant glass fiber make strong of PC material with transparent glass window which made of PC material, it has following features: anti-impact, specious appearance, etc.
2. Plug and socket can turn right 90, and make installation and using conveniently.
3. The plug can fit for all kinds of socket in Europe. There are two kinds of sockets you can choose, two-hole a circular type grounding needle (Product Configuration code is ZA) and two-hole and two grounding strip (Product Configuration code is ZB).
4. 5+1 digits display (99999.1kWh) by step motor type impulse register.
5. Two LED instructions power supply state (green) and signal of energy impulse (red).
6. Standard configuration don’t detection direction of the flow of load current. May select automatic detection the direction of the flow of load current. And instructions (Only red energy pulse signal when working, that is meaning the direction of the flow of load current reverse).
7. Single direction measure single phase two wire active energy consumption. It is nothing with direction of the flow of load current. Complying with standard IEC 62053-21.
8. Directly connect operation, type 1C wiring.

Categories
Energy Meter Base

Meba-Meter Sockets-GTFP200A7J

Application

Meba meter sockets GTFP200A7J is manufactured from 1.2-1.5MM galvanized steel with a baked gary power polyester paint finish to improve corrosion resistance.

Rated current: 200Amps, 600V AC.
Connectors Line and load size #6-350 Cu-AI
Heavy duty tinned copper jaw with reinforced clip.

Ample gutter space for easy wiring.

Convenient knockouts in the side back and bottom.

Lay in type terminal with pressure plates for easy connections.

The fixed hub size 1/2” to 2- 1/2” for option.

Technical Data

Product number

Description

Outline Dimensions

H

W

D

GTFP-200-4J-R

1 Phase,200A, 4 Jaw, Ring type

396

203

108

GTFP -200-5J-R

1 Phase,200A, 4 Jaw, Ring type

396

203

108

GTFP-200-7J-R

3 Phase,200A, 7 Jaw, Ring type

396

203

108

GTFP-200-4J-RL

1 Phase,200A, 4 Jaw, Ringless type

396

203

108

GTFP-200-5J-RL

1 Phase,200A, 5 Jaw, Ringless type

396

203

108

GTFP-200-7J-RL

3 Phase,200A, 7 Jaw, Ringless type

396

203

108

GTFP-200B-4J-RL

1 Phase,200A, 4 Jaw, Ringless type

396

280

108

Features

1.        Standard meter sockets are manufactured from 1.2-1.5MM galvanized steel with a baked gray powder polyester paint finish to improve corrosion resistance.

2.        These meter socket suitable for service voltage 600Vac Max .

3.        Ample gutter space for easy wiring

4.        Convenient knockouts in side back and bottom

5.        Lay in type terminals with pressure plates for easy connections

6.        Meter sockets are designed to accept conduit hubs from 1″ to 2-1/2″ size.[/acc_item][/accordion]

[Download not found]
Categories
Energy Meter Base

Meba-Square Meter Base-GTFP-100A

Application

Meba square meter base GTFP-100A are manufactured from 1.2-1.5MM galvanized steel with a baked gary power polyester paint finish to improve corrosion resistance. Square meter base is also called square meter socket, and characterized with small customer service, temporary service and die cast aluminum.

The Die-cast Aluminium enclosure.Electrostatically applied epoxy and polyester resins,which are baked on.Gray color exterior.

The current carrying parts are made of phosphor copper.

The ground connector is designed to in sure a positive electrical connection by effectively clamping the conductor against a serrated surface.

Technical Data

ProductNumber Description  Outline Dimensions
H W D
GTFP-100A/4J 1Phase,100A 4jaw,ring type 226.5 194 111
GTFP-125A/4J 1Phase,125A4jaw,ringless type 324.2 219 116.2
GTFP-125A/5J 1Phase,125A5jaw ringless type 324.2 219 116.2

Features

1. Standard meter sockets are manufactured from 1.2-1.5MM galvanized steel with a baked gary power polyester paint finish to improve corrosion resistance.

2.These meter socket suitable for single Phase,sevice voltage 600Vac Max.

3. Ample gutter space for easy wiring

4. Conveniet knockout in side back and bottom

5.Lay in type terminal with pressure plate for easy connections

6.Meter sockets are designed to accept conduit hubs from 1”-2-1/2”size

[Download not found]
Categories
Energy Meter Base

Meba-Round Energy Meter Box-GTP100A(4JR)

Round Energy Meter Box-GTP100A(4JR)

1. 100Amps, 120/240VAC

2. Single phase, 4 terminals, 2 or 3 wire Long phosphor copper, Copper connector, 1 or 1 1/4″Hub

The Die-cast Aluminium enclosure.Electrostatically applied epoxy and polyester resins,which are baked on. Gray color exterior.

The current carrying parts are made of phosphor copper.

The ground connector is designed to in sure a positive electrical connection by effectively clamping the conductor against a serrated surface.

Stainless steel sealing ring

Fix hub size:1/2,3/4,1,1-1/4 for option

Applications:

1. Temporary Service

2. Outdoor Advertising

3. Small Customer Service

4. Other Low Amperage Requirements

[Download not found]
Categories
Energy Meter Base

Meba-Electric Metal Meter Socket-GTFP200A4(RL)

Electric Electric Metal Meter Socket GTFP200A4(RL)

* Model Number: GTFP Series Meter Sockets.

* Material: Zinc, Alum, Steel, Malleable .

* Color: Silver Color.

* Rated Current: 200A.

* Rated Voltage: 600V.

1. 200A, 600V AC

2. Connectors Line and load size #6-350 Cu-Al.

3. Heavy duty tinned copper jaw with reinforced clip.

4. C/W center neural bar.

5. NEMA 3R type construction 1.2mm thickness (#18gauge) or 1.5mm thickness (#16 gauge) galvanized steel sheet, electrostatically applied epoxy baked gray powder finished.

6. Ample gutter space for easy wiring.

7. Convenient knockouts in the side back and bottom.

8. Lay in type terminal with pressure plates for easy connections.

9. The fixed hub size: 1/2″ to 2-1/2″ for option.

 

Product Number Description Outline Dimensions
H W D
GTFP-200A-4J-R 1 Phase,200A, 4 Jaw, Ring type 396 203 108
GTFP-200A-5J-R 1 Phase,200A, 4 Jaw, Ring type 396 203 108
GTFP-200A-7J-R 3 Phase,200A, 7 Jaw, Ring type 396 203 108
GTFP-200A-4J 1 Phase,200A, 4 Jaw, Ringless type 396 203 108
GTFP-200A-5J-RL 1 Phase,200A, 5 Jaw, Ringless type 396 203 108
GTFP-200A-7J 3 Phase,200A, 7 Jaw, Ringless type 396 203 108
GTFP-200A-4J-RL 1 Phase,200A, 4 Jaw, Ringless type 396 280 108

 

 

 

 

 

 

 

 

 

 

[Download not found]
Categories
Energy Saving Lamp

Meba watt unit of power MS6123-15W

Meba watt unit of power MS6123-15W is used tri-phosphor rare earth fluorescence power, luminous efficiency ≥ 50Lm/ W, Ra index ≥ 80, Starting temperature can be as low as minus 15 degrees Celsius, Low power consumption, long-life hours, average lifetime: 6000hrs/8000hrs/10000hrs/12000hrs, No noise, fast starting, no stroboscopic, eye-care.

1. Recessed lighting, shelf lighting, ceiling/wall coves
2. Cabinet and under counter lighting, office work station
3. Back lighting, step lighting, light boxes

Meba watt unit of power MS6123-15W

Technical Parameter:

E14/15W/6400K
Un: 170-250 VAC
Hz: 50/60 Hz
Temperature: 0 to 45℃
Life: 8000 H

Up to 80% energy saving over standard incandescent bulbs.
Long life lasts up to 8 times longer than standard incandescent bulbs.
Can operate within 170-250V range.
Equipped with fuse and flame-retardant plastics for safer operation.

Packing way: Standard export carton box

Certificate: CE