Categories
Residual Current Circuit Breaker

Meba Elcb Breaker OLL2-N-4P

Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: OLL2-N
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 4P

Application:

1. OLL2-N, Residual Current Devices for earth leakage detection.

2. It is to be used in association with miniature circuit breakers, its function is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.

3. These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.

Merits:

Good quality , high breaking capability, updated structure,quick trip and guide installation, competitive price,excellent and safe performance,beautiful and compact appearance, etc .

Mounting Requirements:

1. Circumstance temperature -5°C ~ +40°C, average temperature not exceeding 35°C.
2. Altitude above sea level less than 2000 m.
3. Humidity not exceeding 50% at 40°C and not exceeding 90% at 25°C.
4. Installation class II or III.
5. Pollution class 2.
6. Installation method DIN Rail mounting type.
7. The external magnetism shall not be more than 5 times of terrestrial one.
8. Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position.

1. Electromagnetic and Electronic type
2. 70mm wide for 2 pole Din Rail installation.
3. Standsrd: IEC1008/EN61008
4. Rated Voltage(Un): 2pole, 230V AC
5. Rated Current(In): 25, 40, 63A
6. Rated residual operating current(I△n): 30, 100, 300, 500mA
7. Rated residual non-operating current(I△no): 0.5 I△n
8. Residual current off-time: ≤0.1s
9. Minimum value of rated breaking capacity(lm): 630A
10. Rated conditional short-circuit capacity (lnc): 6KA

Categories
Residual Current Circuit Breaker

Meba Elcb Circuit OLL2-N-2P

Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: OLL2-N
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 2P

Application:

1. OLL2-N, Residual Current Devices for earth leakage detection.

2. It is to be used in association with miniature circuit breakers, its function is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.

3. These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.

Merits:

Good quality , high breaking capability, updated structure,quick trip and guide installation, competitive price,excellent and safe performance,beautiful and compact appearance, etc .

Mounting Requirements:

1. Circumstance temperature -5°C ~ +40°C, average temperature not exceeding 35°C.
2. Altitude above sea level less than 2000 m.
3. Humidity not exceeding 50% at 40°C and not exceeding 90% at 25°C.
4. Installation class II or III.
5. Pollution class 2.
6. Installation method DIN Rail mounting type.
7. The external magnetism shall not be more than 5 times of terrestrial one.
8. Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position.

1. Electromagnetic and Electronic type
2. 35mm wide for 2 pole Din Rail installation.
3. Standsrd: IEC1008/EN61008
4. Rated Voltage(Un): 2pole, 230V AC
5. Rated Current(In): 25, 40, 63A
6. Rated residual operating current(I△n): 30, 100, 300, 500mA
7. Rated residual non-operating current(I△no): 0.5 I△n
8. Residual current off-time: ≤0.1s
9. Minimum value of rated breaking capacity(lm): 630A
10. Rated conditional short-circuit capacity (lnc): 6KA

[Download not found]Meba Elcb Circuit OLL2-N-2P open a circuit automatically in the event of an earth fault between phase and earth and/or netural and earth.

Categories
Residual Current Circuit Breaker

Meba RCCB RCBO MBEA-63A

Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: MBACH2
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 2P

Application:

1. MBEA-63A RCCB provide the function of isolation switching and earth leakage protection of electrical circuits.

2. They open a circuit automatically in the event of an earth fault be tween phase and earth and/or neutral and earth.

3. A wide range of current ratings and sensitivities are available. Suitable for domestic, commercial and industrial applications.

 

Merits:

Good quality , high breaking capability, updated structure,quick trip and guide installation, competitive price,excellent and safe performance,beautiful and compact appearance, etc .

Mounting Requirements:

1. Circumstance temperature -5°C ~ +40°C, average temperature not exceeding 35°C.
2. Altitude above sea level less than 2000 m.
3. Humidity not exceeding 50% at 40°C and not exceeding 90% at 25°C.
4. Installation class II or III.
5. Pollution class 2.
6. Installation method DIN Rail mounting type.
7. The external magnetism shall not be more than 5 times of terrestrial one.
8. Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position.

Rated Voltage

1Pole+N: 230/240V AC, 3Pole+N: 400/415V AC

 Rated Current

10, 16, 20, 25, 32, 40A, 50A, 63A

 Rated Frequency

 50/60Hz

 Rated Residual Operating Current

 30, 100, 300, 500mA

Rated residual non-operating current(I no)

 0.5ls n

 Rated Circuit Breaking Capacity

 6KA

Residual current off-time

0.1S

Operating temperatur2

-5 to +55℃

Standard

IEC61008-1

[Download not found]Meba RCCB RCBO MBEA-63A open a circuit automatically in the event of an earth fault between phase and earth and/or netural and earth. A wide range of current ratings and sensitivities are available. Suitable for domestic, commercial and industrial applications.

Categories
Residual Current Circuit Breaker

Meba Legrand Elcb Diagram MB089

Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: MB089
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 2P

Application:

1. MB089 RCD provide the function of isolation switching and earth leakage protection of electrical circuits.

2. They open a circuit automatically in the event of an earth fault between phase and earth and/or netural and earth. A wide range of current ratings and sensitivities are available.

3. Suitable for domestic, commercial and industrial applications.

Merits:

Good quality , high breaking capability, updated structure,quick trip and guide installation, competitive price,excellent and safe performance,beautiful and compact appearance, etc .

Mounting Requirements:

1. Circumstance temperature -5°C ~ +40°C, average temperature not exceeding 35°C.
2. Altitude above sea level less than 2000 m.
3. Humidity not exceeding 50% at 40°C and not exceeding 90% at 25°C.
4. Installation class II or III.
5. Pollution class 2.
6. Installation method DIN Rail mounting type.
7. The external magnetism shall not be more than 5 times of terrestrial one.
8. Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position.

Mode

Electro-magnetic type, electronic type

Residual current characteristics

A, AC

Pole No.

2, 4

Rated making and breaking capacity

630A

Rated current(A)

16 25 40 63A

Rated voltage

240/415V AC

Rated frequency

50/60Hz

Rated residual operating current IΔn(mA)

10, 30, 100, 300, 500

Rated residual non operating current IΔno

0.5IΔn

Rated conditional breaking current Inc

6000A

Rated conditional residual breaking current IΔc

6000A

Tripping duration

Instantaneous tripping≤0.1s

Residual tripping current range

0.5IΔn~IΔn

Electro-mechanical endurance

4000 cycles

Connection capacity

Rigid conductor up to 25mm2

Connection terminal

Screw terminal

Pillar terminal with clamp

Fastening torque

2.0 Nm

Installation

On symmetrical DIN rail 35mm

Panel mounting

Dimensions:

[Download not found]Meba Legrand Elcb Diagram MB089 shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position.