Categories
Front Board Mounted KWH Meters

http://test.meba.net/adb-dial-torque-wrench/

Single Phase Electronic Prepayment Watt-hour Meter

Characteristics and Range of application:

Type DDSY666 Single phase electronic prepayment watt-hour meter (hereafter is the meter) is the most advanced type instrument developed by us adopted the newest technique of personal computer and electronic and currency IC card for purchasing electric energy media. It is assisted by software and hardware technique of computer automation management for getting electric energy fee. It is suitable for measuring active energy in electric net with Single Phase AC 50 Hz/60Hz. The meter must be mounted in the place which temperature is in -10℃~+50℃ and the relativem humidity shall not exceed 85%. And the air should not include corrosive gas, keep away from dust and sand, mildew and insect, etc.

Features:  1. Comparing with the old type MB091, DDSY666 using new material is more suitable for the high temperature areas.  2. Transparent cover 3. LCD display

Main specifications and technical parameter:
The meter are completely conformed to the relative requirements of the
International Standard IEC62053-21(Class 1 or Class 2).

Specifications

Type  Class of precision  Rated voltage Un  Rated current Ib
DDSY666 1 220-240V 15(60)A, 20(80)A, 30(100)A
2

The drawings of external surface:

Prepay-meter

Connection diagrams::

energy meter

Categories
Socket Mounted KWH Meters

Meba-Electromechanical Socket Power Meter-MB351PB

Application

 Meba electromechanical socket power meter MB351PB  is a kind of new style single phase three wire active energy meter, it adopt micro-electronics technique, and imported large scale integrate circuit, use advanced technique of digital and SMT techniques, etc. The meter completely accord with relevant technical requirements of class 1 single phase active energy meter stipulated in international standard IEC 62053-21 and standard ANSI C12.10-1997. It can accurate and directly measure 50Hz or 60Hz active energy consumption from three phase AC electricity net, it is use for setting indoor or outdoor meter box. This meter has 7 digits LCD displays shows power. And there is far infrared communication module in it, can read the meter and set the system parameters conveniently, it has following features: good reliability, light weight, specious nice appearance, convenient installation, etc.

Technical Data

Model Accuracy Reference Voltage(V) Current specifications(A) Starting current(A) Insulation performance
MB351PB Class 1 240 15(100) 0.06 AC voltage 4kv for 1 minute,
1.2/50us waveform
pulse voltage 6kv

Installing Diagram

Dimension for MB351PB
Dimension for MB351PB

 

 

 

 

 

Wiring diagram for MB351PB
Wiring diagram for MB351PB

1. Socket installed, the cover is made of PC material which is transparent and anti-UV molded overall, the terminal is made of black glass fiber which can fire-retardant and enhanced PC material. It has following features: Good weatherability, anti-impact, specious appearance, etc. complying with standard ANSI C12.10-1997.
2. 8 digits LCD display, may select 6+2 digits display (999999.91kWh, default) or 7+1 digits display, can be set by the port of far infrared communication by users.
3. There is a port of far infrared pulse output, use for checking conveniently.
4. There is a port of far infrared state communication, standard configuration communication agreement complying with standard DL/T645-1997, may select other configuration communication agreement.
5. LED instructions signal of energy impulse (red).
6. Automatic detection of the flow of load current, and display on LCD (when display, that is meaning the direction of the flow of load current reverse).
7. Single direction single component measure single phase three wire active energy consumption. It is nothing with direction of the flow of load current. Complying with standard IEC 62053-21.
8. Directly connect operation, type 2S wiring, may select single phase two wire, Directly connect operation, type 1S wiring (Product Configuration code is PA).

[Download not found]
Categories
Front Board Mounted KWH Meters

Meba-Watt Hour Intelligent Meter-MB082WD

Application

Meba watt hour intelligent meter MB082WD is a kind of new style three phase four wire active energy meter, it is on the basis of original D86 three phase electromechanical meter, and fully absorb new technologies about electromechanical meter from domestic and abroad. The meter completely accord with relevant technical requirements of class 2 three phase active energy meter stipulated in international standard IEC 62053-11. It can accurate and directly measure 50Hz or 60Hz active energy consumption from three phase four wire AC electricity net, it is use for setting indoor or out door meter box.

Technical Data

Model Accuracy Reference Voltage(V) Current specifications(A) Starting current(A) Insulation performance
MB082WD Class 2 3X127/220
3X230/440
5(20)
10(40)
20(80)
30(100)
0.025
0.05
0.1
0.15
AC voltage 4kv for 1 minute,
1.2/50us waveform
pulse voltage 8kv

Installing Diagram

 

Dimension for MB082WD
Dimension for MB082WD

 

 

 

 

Wiring diagram for MB082WD
Wiring diagram for MB082WD

 

1. Front board three fixed installation, the cover is made of PC material which is transparent and anti-UV molded overall, the bottom of the meter is made of black glass fiber which can fire-retardant and enhanced PC material, and the terminal is made of quality bakelite material which is moisture-resistant, fire-retardant, high temperature molded overall. It has following features: good weatherability, anti-impact, specious appearance, etc.
2. The meter frame adopt aluminum molding with excellent mechanical strength, stable structure and anti-impact.
3. Voltage components and current components is used of double insulation structure, has good electrical characteristics.
4. Standard configuration the meter adopt magnetic thrust bottom bearing, oriented bearing is made of lubrication graphite bush and stainless steel needle. It has following features: Small abrasion, long life and minimal friction, etc. May select double gem bearing (Product Configuration code is WP).
5. All kinds of error adjustment mechanism adopt no step shifting mechanism. The meter starting and creeping needn’t to be adjust which is finished by anti-creeping hole of disc and convenient for adjusting by users.
6. Standard configuration 5 digits display by drum wheel mechanical register, may select 6 digits display by drum wheel mechanical register (Product Configuration code is WJ).
7. Standard configuration without the device which can prevent retrograde, may select add the function of prevent retrograde. (Please specified when ordering).
8. Three components measure three phase four wire active energy consumption. Complying with standard IEC 62053-11.
9. Standard configuration for direct connect operation, type 16A wiring, we can also choose another type of wiring, and use CT (Product Configuration code is WE), type 48A wiring, and PT & CT (Product Configuration code is WF), type 48A wiring for operation.
10. Extension terminals cover, in order to protect to use safety.

[Download not found]
Categories
Front Board Mounted KWH Meters

Meba-Reading Electricity Meter-MB061AL

Application

Meba reading electricity mete MB061AL is a kind of new style three phase four wire active energy meter. The meter completely accord with relevant technical requirements of class 1 three phase active energy meter stipulated in international standard IEC 62053-23 and class 2 three phase reactive energy meter. It can accurate and directly measure 50Hz or 60Hz active energy consumption from three phase four wire AC electricity net. This meter has LCD displays shows the active energy consumption, and there are far infrared and RS485 communication module in it, contact with all kind of AMR system conveniently. It has following features: good reliability, small volume, light weight, specious nice appearance, convenient installation, etc.

Technical Data

Model Accuracy Reference Voltage(V) Current specifications(A) Starting current(A) Insulation performance
MB061AL Active Class 1
Reactive Class 2
3X127/220
3X230/440
5(30)
10(60)
20(100)
0.02
0.04
0.08
AC voltage 4kv for 1 minute,
1.2/50us waveform
pulse voltage 6kv

Installing Diagram

 

Dimension for MB061AL
Dimension for MB061AL

 

 

Wiring diagram for MB061AL
Wiring diagram for MB061AL

1. Front board three fixed installation, the cover is made of PC material which is transparent and anti-UV molded overall, the bottom of the meter and the terminal is made of quality bakelite material which is moisture-resistant, fire-retardant, high temperature molded overall. It has following features: good weatherability, high rigid, good insulation performance, etc.
2. Have six tariffs, may select 12 daily period of times. You can set the date arbitrary which can automatic read the meter every month. May select single tariff function in weekend. (Please specified when ordering).
3. There are a clock and Maintenance-free backup lithium batteries in it. Battery capacity detection and display all the time. It can keep the electricity data for 12 months. The data can be kept forever after power cut off.
4. May select cycle display (default) or push the button itemized display, it can display 14 data at most. Can select the data which displayed. The decimal median which displayed can choose set one or two.
5. There are a polarity port of pulse output passive closed and a nonpolarity port of pulse output passive distant (the output rate is 10 or 100 imp/kWh, can select ). Complying with standard IEC 62053-31 and DIN 43864.
6. There are far infrared and a port of RS485 communication data. It is use for setting and reading the meter. Set and operation have password protection, communication agreement complying with standard DL/T645-1997.
7. Ten LED instructions respectively power supply state, signal of energy impulse, the direction of the flow of load current, the state rates just now and the data communications state.
8. Detect active and reactive energy, active and reactive power, voltage, current and frequency, etc. of three phase four wire forward and reverse. Complying with standard IEC 62053-21 and IEC 62053-23.
9. Standard configuration direct connect operation, type 16B wiring, we can also choose another type of wiring, and use CT (Product Configuration code is AO) and PT & CT (Product Configuration code is AQ) for operation.
10. Standard configuration short terminals cover, may select extension terminals cover, in order to protect to use safety.  (Product Configuration code is AM).

[Download not found]
Categories
Front Board Mounted KWH Meters

Meba-Multifunctional Prepaying Meters-MB091QB

Application

 Meba multifunctional prepaying meters MB091QB is a kind of single phase two wire active energy meter which purchase electricity by IC card, electric energy measuring, load control and using electricity management. The meter completely accord with relevant technical requirements of class 1 single phase active energy meter stipulated in international standard IEC 62053-21. It can accurate and directly measure 50Hz or 60Hz active energy consumption from single phase AC electricity net, it is use for setting indoor or out door meter box. This meter has LCD display power. It has following features: god reliability, light weight, specious nice appearance, convenient installation, etc.

 

Technical Data

Model Accuracy Reference Voltage(V) Current specifications(A) Starting current(A) Insulation performance
MB091QB Class 1 127
230
5(30)
10(60)
20(100)
0.02
0.04
0.08
AC voltage 4kv for 1 minute,
1.2/50us waveform
pulse voltage 6kv

 

Installing Diagram

 

 

 

Dimension for MB091QB
Dimension for MB091QB

 

 

 

 

Wiring diagram for MB091QB
Wiring diagram for MB091QB

 

 

1. Standard configuration one meter one card, can repeat input money from PC machinery which with IC programmer, may select one-time recharge card. (Please specified when ordering).
2. It has IC card with code and data against false, standard configuration use storage IC card, may select non-contact RF card. (Product Configuration code is QJ)
3. Standard configuration payment by kWh, may select payment by money. (Please specified when ordering).
4. Standard configuration of the prepayment management system use of single version, may select network version. (Please specified when ordering).
5. It has load control and function of automatic fault detection and instructions, standard configuration without function of open terminals cover and detection, may select open terminals cover and cut power. (Please specified when ordering).
6. Standard configuration 7 LCD digits display, 6+1 digits display (999999.1kWh), may select 5+1LED digits display. (Product Configuration code is PB).
7. A port of pulse output passive closed (polarity), complying with standard IEC 62053-31 and standard DIN 43864.
8. Three LED instructions power supply state (green), signal of energy impulse (red) and direction of the flow of load current (yellow).
9. Automatic detection the direction of the flow of load current. When the yellow LED display, that is meaning the direction of the flow of load current reverse.
10. Single direction single component measure single phase two wire active energy consumption. It is nothing with direction of the flow of load current. Complying with standard IEC 62053-21.
11. Direct connect operation, there are two types wiring you may select. Standard configuration type 1A wiring, may select type 1B wiring (Product Configuration code is QA).
12. Front board three fixed installation, standard configuration extension terminals cover, in order to protect to use safety, may select short terminals cover.  (Product Configuration code is QD).

[Download not found]
Categories
Front Board Mounted KWH Meters

Meba-Phase Control Power Meters-MB074SI

Application

Meba phase control power meters MB074SI is a kind of new style single phase two wire active energy meter, it is designed on the basis of original DD284 single phase electromechanical meter, and fully absorb new technologies about electromechanical meter from domestic and abroad. The meter completely accord with relevant technical requirements of class 2 single phase active energy meter stipulated in international standard IEC 62053-11. It can accurate and directly measure 50Hz or 60Hz active energy consumption from single phase AC electricity net, it is use for setting indoor or out door meter box. The meter has novel design, rational structure, and it can display total energy consumption by drum wheel mechanical register. It has following features: compact structure design, small size, economy benefits, specious appearance, etc.

Technical Data

Model Accuracy Reference Voltage(V) Current specifications(A) Starting current(A) Insulation performance
MB074SI Class 2 127
230
10(20)
20(40)
30(60)
40(80)
0.05
0.1
0.15
0.2
AC voltage 2kv for 1 minute,
1.2/50us waveform
pulse voltage 6kv

Installing Diagram

 

 

Dimension for MB074SI
Dimension for MB074SI

 

 

 

Wiring diagram for MB074SI
Wiring diagram for MB074SI

1. Front board two fixed installation, the cover is made ABS engineering plastics molded overall which is black, fire-retardant and has a transparent glass window, the bottom of the meter is made of quality steel which is after double-through antirust processing, and the terminal is made of quality bakelite material which is moisture-resistant, fire-retardant, high temperature molded overall. It has following features: Economy benefits, specious appearance, etc.
2. The meter frame adopt aluminum molding with excellent mechanical strength, stable structure and anti-impact.
3. Voltage components and current components is used of double insulation structure, has good electrical characteristics.
4. Standard configuration voltage circuit and current circuit connect in the case, may select connect outside.
5. Standard configuration bottom bearing is used of single-precious stone bearing, oriented bearing is made of high wear resistance copper alloy bush and stainless steel needle. May select magnetic thrust bearing (Product Configuration code is SA) or double gem bearing (Product Configuration code is SE).
6. All kinds of error adjustment mechanism adopt no step shifting mechanism. The meter starting and creeping needn’t to be adjust which is finished by anti-creeping hole of disc and convenient for adjusting by users.
7. Standard configuration 5 digits display by drum wheel mechanical register, may select 6 digits display by drum wheel mechanical register (Product Configuration code is SK).
8. Standard configuration without the device which can prevent retrograde, may select add the function of prevent retrograde. (Please specified when ordering).
9. Single component measure single phase two wire active energy consumption. Complying with standard IEC 62053-11.
10. Direct connect operation, there are two types wiring you may select. Standard configuration type 1B wiring, may select type 1A wiring (Product Configuration code is SJ).
11. Standard configuration extension terminals cover, in order to protect to use safety, may select short terminals cover. (Product Configuration code is OI)

[Download not found]
Categories
Front Board Mounted KWH Meters

Meba- Energy Meters Digital -MB073RJ

Application

Meba energy meters digital MB073RJ is a kind of new style single phase two wire active energy meter, it is designed on the basis of original DD862 single phase electromechanical meter, and fully absorb new technologies about electromechanical meter from domestic and abroad. The meter completely accord with relevant technical requirements of class 2 single phase active energy meter stipulated in international standard IEC 62053-11. It can accurate and directly measure 50Hz or 60Hz active energy consumption from single phase AC electricity net, it is use for setting indoor or out door meter box. The meter has novel design, rational structure, and it can display total energy consumption by drum wheel mechanical register. It has following features: high overload, power loss, long-life, specious appearance, etc.

Technical Data

Model Accuracy Reference Voltage(V) Current specifications(A) Starting current(A) Insulation performance
MB073RJ Class 2 127
230
5(20)
10(40)
20(80)
30(100)
0.025
0.05
0.1
0.15
AC voltage 2kv for 1 minute,
1.2/50us waveform
pulse voltage 6kv

Installing Diagram

 

Dimension for MB073RJ
Dimension for MB073RJ

 

 

 

Wiring diagram for MB073RJ
Wiring diagram for MB073RJ

1. Front board three fixed installation, the cover is made of high definition transparent glass material molded overall, the bottom of the meter and the terminal is made of quality bakelite material which is moisture-resistant, fire-retardant, high temperature molded overall. It has following features: good weatherability, high rigid, specious appearance, etc.
2. The meter frame adopt aluminum molding with excellent mechanical strength, stable structure and anti-impact.
3. Voltage components and current components is used of double insulation structure, has good electrical characteristics.
4. Standard configuration bottom bearing is used of double gem bearing, oriented bearing is made of high wear resistance copper alloy bush and stainless steel needle. It has following features: long life and minimal friction, etc. May select magnetic thrust bearing (Product Configuration code is RD).
5. All kinds of adjustment mechanism adopt no step shifting mechanism. The meter starting and creeping needn’t to be adjust which is finished by anti-creeping hole of disc and convenient for adjusting by users.
6. Standard configuration 6 digits display by drum wheel mechanical register, may select 5 digits display by drum wheel mechanical register (Product Configuration code is RG).
7. Standard configuration without the device which can prevent retrograde, may select add the function of prevent retrograde. (Please specified when ordering).
8. Single component measure single phase two wire active energy consumption. Complying with standard IEC 62053-11.
9. Direct connect operation, there are two types wiring you may select. Standard configuration type 1B wiring, may select type 1A wiring (Product Configuration code is RK).
10. Extension terminals cover, in order to protect to use safety.

[Download not found]
Categories
Front Board Mounted KWH Meters

Meba-Transparent Power Meter Google-MB313TH

Application

Meba power meter google MB313TH  is a kind of new style single phase two wire active energy meter, it adopt micro-electronics technique, and imported large scale integrate circuit, use advanced technique of digital and SMT techniques, etc. The meter completely accord with relevant technical requirements of class 1 single phase active energy meter stipulated in international standard IEC 62053-21. It can accurate and directly measure 50Hz or 60Hz active energy consumption from single phase AC electricity net, it is use for setting indoor or setting out door directly, and it can display total energy consumption by step motor type impulse register. It has following features: good reliability, small volume, light weight, specious nice appearance, convenient installation, etc.

Technical Data

Model Accuracy Reference Voltage(V) Current specifications(A) Starting current(A) Insulation performance
MB313TH Class 1 127
230
5(30)
10(60)
20(100)
0.02
0.04
0.08
AC voltage 4kv for 1 minute,
1.2/50us waveform
pulse voltage 6kv

Installing Diagram

 

 

Dimension for MB313TH
Dimension for MB313TH

 

 

 

 

Wiring diagram for MB313TH
Wiring diagram for MB313TH

1. Front board three fixed installation, the cover is made of PC material which is transparent and anti-UV molded overall, the bottom and the terminal of the meter are made of black glass fiber which can fire-retardant and enhanced PC material, and the IP rating up to IP56. It has following features: good weatherability, anti-impact, good insulation performance, specious appearance, etc.
2. Standard configuration the bottom and the terminal of the meter are closed by the screw of the meter, may select the bottom and the terminal of the meter are closed by ultrasonic. (Please specified when ordering).
3. Standard configuration 5+1 digits display (99999.1kWh) by step motor type impulse register. May select 6+1 digits display (Product Configuration code is UC).
4. Standard configuration one port of pulse output passive (polarity), May select increase a distant port of pulse output passive (nonpolarity). And contact with all kind of AMR system conveniently, Complying with standard IEC 62053-31 and DIN 43864.
5. Standard configuration only one LED instructions signal of energy impulse (red), may select add instructions power supply state (green) and automatic detection the direction of the flow of load current and instructions by LED (when display yellow, that is meaning the direction of the flow of load current reverse). Please specified when ordering.
6. Single direction single component measure single phase two wire active energy consumption. It is nothing with direction of the flow of load current. Complying with standard IEC 62053-21.
7. Direct connect operation, there are two types wiring you may select. Standard configuration type 1A wiring, may select type 1B wiring (Product Configuration code is AH).
8. Standard configuration extension terminals cover, in order to protect to use safety, may select short terminals cover. (Product Configuration code is TG).

[Download not found]
Categories
Front Board Mounted KWH Meters

Meba-tested meters-MB071VB

Application

Meba-tested meters-MB071VB is a kind of new style single phase two wire active energy meter, it is on the basis of original single phase electromechanical meter, and fully absorb new technologies about electromechanical meter from domestic and abroad, and development long-life technology. The meter completely accord with relevant technical requirements of class 2 single phase active energy meter stipulated in international standard IEC 62053-11. It can accurate and directly measure 50Hz or 60Hz active energy consumption from single phase AC electricity net, it is use for setting indoor or out door meter box, and it can display total energy consumption by drum wheel mechanical register. It has following features: high overload, power loss, long-life, specious appearance, etc.
Technical Data

Model Accuracy Reference Voltage(V) Current specifications(A) Starting current(A) Insulation performance
MB071VB Class 2 127
230
5(30)
10(60)
20(100)
0.025
0.05
0.1
AC voltage 4kv for 1 minute,
1.2/50us waveform
pulse voltage 8kv

Installing Diagram

Dimension for Meba-tested meters-MB071VB
Dimension for Meba-tested meters-MB071VB

 

Wiring diagram for Meba-tested meters-MB071VB
Wiring diagram for Meba-tested meters-MB071VB

1. Front board three fixed installation, the bottom of the meter and the terminal is made of quality bakelite material which is moisture-resistant, fire-retardant, high temperature molded overall. The cover is also made of bakelite material and has a transparent glass window. It has following features: good weatherability, high rigid, specious appearance, etc.
2. The meter frame adopt top-quality steel plate once molding with excellent mechanical strength, stable structure and anti-impact.
3. Voltage components is used of all closed vacuum pouring coil by epoxy resin. Current components is used of double insulation structure, has good electrical characteristics.
4. The meter adopt magnetic thrust bottom bearing, oriented bearing is made of lubrication graphite bush and stainless steel needle. It has following features: small abrasion, long life and minimal friction, etc.
5. All kinds of adjustment mechanism adopt no step shifting mechanism. The meter starting and creeping needn’t to be adjust which is finished by anti-creeping hole of disc and convenient for adjusting by users.
6. Standard configuration 5 digits display by drum wheel mechanical register, may select 6 digits display by drum wheel mechanical register (Product Configuration code is VE).
7. Single component measure single phase two wire active energy consumption. Complying with standard IEC 62053-11.
8. Direct connect operation, there are two types wiring you may select. Standard configuration type 1A wiring, may select type 1B wiring (Product Configuration code is VA).
9. Standard configuration extension terminals cover, in order to protect to use safety, may select short terminals cover. (Product Configuration code is RB).

[Download not found]