Categories
Miniature Circuit Breaker

Miniature circuit breaker MB516C made by Meba

Miniature circuit breaker MB516C made by Meba

Meba miniature circuit breaker MB516C, adopts advanced design technology, it has protective function as shortage as overload, and are used in lighting distribution system industry, commerce and dwelling, and protecting fractional electric motors, and Meba miniature circuit breaker MB516C, also have many merits of high protective grade(up to IP20), high breaking capacity, reliable sensitive action, convenient, multiple assembling, long life etc. They are mainly adapted to the circuit of AC 50Hz, 230V in single pole; 400V in double, three, four poles for protecting overload and short circuit. Meanwhile Meba miniature circuit breaker MB516C, are also used in turning on or off the electric apparatus and lighting circuit under the normal condition.

Meba miniature circuit breaker MB516C

Technical parameters:

 

IEC 60898 IEC60947

Tropicalization

Relative Humidity

93% RH at 25℃

Room Temperature

-5℃ a 40℃

Electrical Properties

Rated at 40℃

A

6/10/16/20/25/32/40/50/63

Rated operating voltage at 40℃

Vac

240/415

Nominal Frequency

Hz

50/60

Interrupting Capacity at 230V

kA

6

Operating temperature

-5℃ a 40℃

Degree of Protection

IP20

Number of poles

1/2/3/4

Conductor cross section (minimum allowable)

mm2

25

Minimum number of power moves

6000

Minimum number of mechanical operations

20000

Operation curve

B/C/D

Current Trip Curve

A

5 a 10 In

Characteristic Intervention

attach

Type Of Assembly

FOR RIEL DIN 35 mm

Operation Indicator Window

The circuit breaker have an operating window color display that shows the state in which it is (connected or disconnected).

Features

MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current (Type C), 3 to 5 times rated current (Type B), 10 to 14 times rated current (Type D)

BIMETAL: ensures the breaker trip when overloaded.

ARC CHAMBER: effectively dissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit.

Present Certificates

CE CB

ISO 9001-2000 awarded by the competent certification body, Meba is qualified in the manufacturing of the object

IEC 60898 standards in the manufacture of the goods

Curve compliance issued Shot by an accredited laboratory for effect

Life, given by Meba to ensure that the life of the goods offered by at least 15 years.

Testing For Acceptance

Before receiving the circuit breakers(breakers), customers may perform the tests may be necessary to ensure compliance with the technical specifications.

Packing

The packaging is sure that withstand any adverse conditions during transport and handling to the warehouse of cutomers.

Dial Century, Year, Month and Batch

In one of its sides the breaker is marked with permanent ink, year, month and batch.

Catalog

Attach catalogs indicating the technical specification

Shows

Submit sample of the product offered

Technical Warranty

2 YEARS

Place of Delivery

CNF&FOB

Delivery

25 DAYS

Categories
Miniature Circuit Breaker

Meba electrical circuit breaker XYDB7

Meba electrical circuit breaker XYDB7

Meba electrical circuit breaker XYDB7

have protective function as shortage as overload, and used in lighting distribution system, industry, commerce, and protect fractional electric motors. And they also have many merits of high protective grade(up to IP20),high break capacity, reliable sensitive action, convenient, multi-pole assembling, long life etc. They are mainly adapted to the circuit of AC 50Hz,230V in single pole,400V in double, three, four poles for protecting overload and short circuit. Meanwhile, they are also used in turning on or off the electric apparatus and lighting circuit under the normal condition.

Meba electrical circuit breaker XYDB7

Electrical specification EN60898(IEC898 GB10963-99)
Conforms to standard of electrical 230V/400V;50/60Hz
Rated current(Ue) 10KA IEC898(0.5~63A)
15KA IEC947-2(0.5~63A)
Short circuit breaking capacity of DC Max.48V(KL7…,10KA)single pole
Max.250v(Kl7-DC,6KA)single pole
Perfermance C,D charaectisistic curve
Max.fuse that can be connected to 100AgL(>10KA)
Selective grade 3
Working ambient temperature -5 ℃ to +40 ℃
Enclosed protective class P40(Under mounting)
Life:Electrical  Mechanical No less than 8000 times
No less than20000 times
The length of exposed plane 45mm
Enclosure height 80mm
Enclosure width 17.5mm per pole(single pole)
35mm:1P+N(two pole)
Mounting manner Used for track of 35mm of IEC standard
Terminal manner Two-function terminal can connect with busbar and conducting wire
Terminal block capacity Wire 1-25mm2
Conducting wire 0.8-2mm
Categories
Miniature Circuit Breaker

Meba RDP50 4P 23A Miniature Circuit Breaker

Meba RDP50 4P 23A Miniature Circuit Breaker is used in lighting distribution system or motor distribution system for protection overload and short-circuit in the system. The product is neoteric in structure, light in weight, reliable and excellent in performance. It has high breaking capacity, can trip quickly, and its case and items are adopted by high fire-resistant and shockproof plastics. The product, with long life, is mainly used in AC 50Hz/60Hz single-pole 230V or two, three, four pole 400V circuit for overload and short-circuit protection as well as for unfrequent on-and-off switching electric equipment and lighting circuit in normal case. The products comply with IEC 60898.

Meba RDP50 4P 23A Miniature Circuit Breaker

Technical parameters

Type: RDP50
Rated Voltage: 65VDC, 230/400V
Rated Current(A): 1, 2, 3, 6, 10, 15, 20, 25, 30, 40, 50
Breaking Capacity: 65VDC 2000A; 230/400VAC 1000A; O-CO-O
Life: Mechanical Life: 10000 times; Electric Life: 6000 times
Ambient Temperature: -40+85
Insulated resistance: 100M(500VDC)
Operation resistance: 2000V 1min
Overload release capacity: Follow
Auxiliary contact point: 230V(AC) 1A
Connection ways: Screw
Resist vibration: 1055Hz 1028Hz 1.5mm 2555Hz 5g
Pole: 1P,2P,3P
Weight : 1P 95g, 2P 190g, 3P 285g

Dimension

RDP50 Over-Current Protection Property

Current Character 232 release time(s)
Model Model Pole In 1.5In 2In 6In 10In
AC 62M Single Non-release 5-60 1.8-20 0.04-0.5 0.01-0.1
Two Non-release 7-30 3.6-10 0.18-0.7
DC 52M Single Non-release 3-43 0.8-13 0.02-1 0.04-0.19
Two Non-release 5.5-22 2.6-7.7 0.14-0.48 0.01-0.03
Categories
Miniature Circuit Breaker

Meba electric fuse MBP41

 is used in the single phase residual current of AC50/60Hz, rated voltage 220V or below for protecting electron circuit from overload and short circuit This product has advantages of high breaking capacity, small volume, width is only 18mm. Zero and live wire are cut off at the same time, preventing the person and fire danger. It is the ideal  distribution protective switch in the civil residence field at present. This product conforms to the requirement of IEC60898.

Meba electric fuse MBP41

 

. Pole No.: 1P,2P,3P,4P
. Rated voltage: AC 230V
. Rated current (A): 63A, 80A,100A
. Tripping curve: C, D
. Rated short-circuit capacity(Icn): 4000A
. Rated frequency: 50/60Hz
. Energy limiting class: 3
.  Current Trip Curve: Type C: 5 a 10 In, Type D: 10 a 14 In

Features:

MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current (Type C), 10 to 14 times rated current (Type D)

BIMETAL: ensures the breaker trip when overloaded.

ARC CHAMBER: effectively dissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit.

Categories
Miniature Circuit Breaker

Meba breaker MBL7 DPN

Meba breaker MBL7 DPN

  •  protecting against electrical leakage (residual current)
  • 50Hz or 60Hz, rated voltage single-phase 240V, three phases 415V, rated current up to 40A
  • cut off the power within the time of 0.1s automatically when the current exceeds the fixed value
  • protect the un-frequent switch-over of the circuit under normal conditions
  • conforms to IEC1009.1 and GB16917.1.

Meba breaker MBL7 DPN

Rated Voltage 230V;50/60HZ
Rated Current 6A 10A 16A 20A 25A 32A 40A
Rated Breaking Capacity 6kA
Trip Character C Characteristic Curve
Max fuse that can be connect to Max 100A gl/gG(>6kA)
Selection Grade 3
Working Enviroment Termperature -5~+40°C
Case Protection Grade IP40
Electrical life ≥8000times

 

MACHANICAL PARAMETER

The length of exposed plate 45mm
Enclosure heitht 80mm
Enclosure width 17.5 (1P+N)
Mounting According to IEC 35 mm DIN-Rail
Terminal Connection of exaltation
Terminal block capacity 1-6mm2

 

DIMENSION

 

 

Moller 1 Modular 1P+N Circuit Breaker L7 circuit breaker DPN