MTmax Moulded Case Circuit Breaker

Meba MCCB Breaker Protection MBS250

1. EZC-250F MCCB series is one of breakers which adopts international advanced design, manufacture technology to develop.

2.The rated insulating voltage is 500V, suitable for AC 50Hz(60Hz), rated working voltage 500V or below, rated working current is 15A to 250A of circuit and use in distributing electric energy.

3. It complies with standard of IEC60947-2.

Classification:

1. Installation way: Mounted vertically, Horizontal installation;
2. By use of circuit breaker usage: Distribution protection, Motor protection;
3. According to the mode of wiring points: Front panel wiring, Back panel wiring , Plug-in connection;
4. According to the mode of operation: direct operating handle, External turning the handle operations, electric operation;
5. By release type distinction: instantaneous action release (magnetic release), thermal + electromagnetic release (duplex); electronic release;
6. Poles Number: 3poles, 4poles;

Type MBS-125 MBS-250
Poles No. 3 3
Rated Current In(A) 16, 20, 25, 32, 40, 50, 60, 80, 100, 125 63, 80, 100, 125, 160, 200, 225, 250
Rated Insulation Voltage Ui(V) 690 690
Rated Impulse Withstand Voltage(Kv) 6 8
Utilisation Category A A
Rated Breaking Capacity(KA)Icu/Ics 220/240VAC 25/7 40/40
380/415VAC 18/5 25/25
660/690VAC 12/6

Working condition:
1.The altitude not exceeding 2000m
2.The ambient temperature is from +40°Cto -5°C
3.Ambient environment is free from explosive danger and air or dust, which may cause corrosion of metal or weakness of insulation.
4.Ambient environment is free from erosion of rain or snow.
5.Pollution degree 3
6.Over-voltage category III

Trip characteristic:
The thermodynamic release of the breaker has the advantages of inverse time-delay while the magnetic release the instantaneous operation as shown on table 2(distribution circuit breaker)and table 3(motor protection circuit breaker).

Overall & Installation Dimensions:

MBS series Overall & Installation Dimensions

[Download not found]Meba MCCB Breaker Protection MBS250 is big ampere circuit breaker  with high breaking capacity match with RCCB, MCB  use  to protection power distribution equipment safety. 

Categories
NF Moulded Case Circuit Breaker

Meba Moulded Case Circuit Breaker NF100-CP

1. NF series thermal magnetic type molded case circuit breaker, developed from Mitsubishi type, included NF-CS, NF-SS, NF-CP, NF-SP, NF-HP, NF-CW series.

2. Rated working voltage 690V, 50HZ or 60HZ, and rated working current from 3A to 800A.

3. It mainly used in distributing electric energy and protect the electrical circuit and power equipment from damages caused by overload, short circuit or under-voltage in the distribution network.

4. It complies with IEC60947-2 and GB14048.2 standards.

Working Conditions and Mounting Environments
1. The altitude should be less than 2000m
2. The ambient medium temperature should within -5℃ to +40℃
3. This moulded case circuit breaker is resistant to moisture, salt fog, nuclear radiation, and mildew
4. The maximum tilt angle is 22.5°
5. MCCB can still work reliably if the product is subjected to vibration from ships or earthquakes(4g)

Parameters of NF-100 Moulded Case Circuit Breaker

Frame Current(A) 100
Model NF-100C NF-100S NF-100M NF-100H
Rated Current in(A) 16,20,32,40,50,63,80,100A
Poles 2 3 4 2 3 4 2 3 4 2 3 4
Rated Voltage Ue(V) AC400
Rated Insulation Voltage Ui(V) AC690
(KA)AC400 Short-Circuit Interrupting Capacity Icu/Ics 15/7.5 50/25 50/35 80/50
Operation Life(cycle) Power on 3000
Power off 7000
Dimensions(mm) a 60 90 120 60 90 120 90 90 120 90 90 120
b 155 155 155 155
c 68 68 68 83
ca 90 90 90 105
Weight(kg) 0.7 1.0 0.75 1.1 1.4 0.75 1.1 1.4 0.75 1.1 1.4
Electrical-operation Device(MD)
External Rotary Handle
Automatic Tripping Device thermal-magnetic thermal-magnetic thermal-magnetic thermal-magnetic

[Download not found]Meba Moulded Case Circuit Breaker NF100-CP is update thermal magnetic type mccb max 100A against overload & short circuit.