Categories
Miniature Circuit Breaker

Meba mcb rccb MB1-63-50A

Meba mcb rccb MB1-63-50A

Meba mcb rccb MB1-63-50A , this series Miniature Circuit Breaker is nice in appearance, reasonable in structure, sound in feature and high in breaking capacity. Installed with standard din rail, it is convenient and easy in usage. It is mainly used in the line of AC 50/60Hz, rated working voltage to 240V/415V, and rated current to 63A as protection against overload and short-circuit. It can be used as infrequent on-and-off operation and changeover.
It complies with standard of GB10963 and IEC/EN60898.

Meba mcb rccb MB1-63-50A

Technical parameters

Frame class

63A

Rated working voltage

240V/415V

Rated frequency

50/60Hz

Rated working current

1、3、6、10、16、20、25、32、40、50、63A

Making and breaking capacity

6000A(6~40A),4500A(50、63A)

Release type

B、C、D

Poles

1、2、3、4P

Mechanical life

20000

Electric life

4000

The over-current tripping unit protection feature   

Sequence
NO .

Release

Test
current I/In

Start state

Tripping
time

Expected
result

1

B、C、D

1.13In

Cold state

t≤1h

Not tripping

2

B、C、D

1.45In

Start right after
the serial NO .
1 test

t<1h

Tripping

3

B、C、D

2.55In

Cold state

1s<t<60s

Tripping

4

B
C
D

3In
5In
10In

Cold state

t≤0.1s

Not tripping

5

B
C
D

5In
10In
20In

Cold state

t<0.1s

Tripping

 

Dimensions(mm)

Meba-mcb-and-mccb-MB1-63-40A

Characteristics curve

Meba mcb and mccb MB1-63-40A Characteristics curve

Categories
Miniature Circuit Breaker

Meba mcb rcd MB49

Meba mcb rcd MB49

Meba mcb rcd MB49  major export to South America, Middle East market, has light weight, small size, novel structure and excellent performance. They are mounted in the metal distribution board and used in guesthouses. block of fiats, high buildings, squares, airports, railway stations, plants and enterprises etc, in AC circuits 240V(single pole)up to 415V(3poie)50Hz for protection of overload short circuit and for circuit changeover in lighting system. Breaking capacity is 3KA. The items comply with BS&NEMA STANDARD.

Feature:

MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current (Type C), 3 to 5 times rated current ( Type B ), 10 to 20 times rated current ( Type D )

BIMETAL: ensures the breaker trip when overloaded.

ARC CHAMBER: effectively dissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit.

Meba mcb rcd MB49

Technical parameters

ropicalization Relative Humidity 93% RH at 25℃
Room Temperature 10℃ a 60℃
Electrical Properties Rated at 40℃ A 6/10/15/20/30/40/50/63
Rated operating voltage at 40℃ Vac 120/240/415
Nominal Frequency Hz 50/60
Interrupting Capacity at 230V kA 3
Operating temperature -5℃ a +40℃
Degree of Protection IP20
Number of poles 1,2,3,4
Conductor cross section (minimum allowable) mm2 25
Minimum number of power moves 4000
Minimum number of mechanical operations 6000
Operation curve B/C/D
Current Trip Curve A Type B 3a 5 In
Type C 5 a 10 In
Type D 10 a 14 In
Characteristic Intervention attach
Type Of Assembly NEMA Type
Features MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current (Type C), 10 to 14 times rated current ( Type D )
BIMETAL: ensures the breaker trip when overloaded.
ARC CHAMBER: effectively dissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit.
Categories
Residual Current Circuit Breaker

Meba rccb MB62

Meba rccb MB62

Meba rccb MB62 ,Residual Cur rent Devices for earth leakage detection. It is to be used in association with miniature circuit breakers, its function is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application. These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.

Application:

1. MB64, Residual Current Devices for earth leakage detection.

2. It is to be used in association with miniature circuit breakers, its function is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.

3. These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.

Merits:

Good quality , high breaking capability, updated structure,quick trip and guide installation, competitive price,excellent and safe performance,beautiful and compact appearance, etc .

Mounting Requirements:

1. Circumstance temperature -5°C ~ +40°C, average temperature not exceeding 35°C.
2. Altitude above sea level less than 2000 m.
3. Humidity not exceeding 50% at 40°C and not exceeding 90% at 25°C.
4. Installation class II or III.
5. Pollution class 2.
6. Installation method DIN Rail mounting type.
7. The external magnetism shall not be more than 5 times of terrestrial one.
8. Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position.

[tab_item title=”Parameter”]

Meba rccb MB62

Technical Parameter:
– Electromagnetic and Electronic type
– Rated residual non-operating current(Ino): 0.5 In
– 35mm wide for 2 pole Din Rail installation.
– Residual current off-time: 0.1s
– Standsrd: IEC1008/EN61008
– Minimum value of rated breaking capacity(lm): 630A
– Rated Voltage(Un): 2pole, 230V AC
– Rated conditional short-circuit capacity (lnc): 6KA
– Rated Current(In): 25, 40, 63A
– Rated residual operating current(In): 30, 100, 300, 500mA
Categories
Residual Current Circuit Breaker

Meba rccb and mcb MBL1210C

Meba rccb and mcb MBL1210C

Meba rccb and mcb MBL1210C

has introduced the F200 Ground Fault Equipment Protector (GFEP), designed to protect equipment against damaging line-to-ground currents by disconnecting all ungrounded conductors of the faulted circuit. A ground fault is caused by an insulation loss between a live conductor and an exposed conductive part that creates a flow of current to the ground. Most short circuits initially manifest as ground faults, which, if undetected, can cause serious and costly damage to electrical systems and equipment. An  F200 GFEP added to an electrical system trips when the system leaks a significant current to ground, immediately preventing the potential short circuit before such damage can occur.

The MEBA F200 GFEP line consists of the 2-pole F202 for single phase networks, and the 4-pole F204 for split phases, Delta and Wye networks.  The F200 GFEP immediately detects ground faults by continuously measures the current balance between live conductors and the neutral using a toroidal current transformer.

Application:

1. MBL1210C, Residual Current Devices for earth leakage detection.

2. It is to be used in association with miniature circuit breakers, its function is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.

3. These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.

Merits:

Good quality , high breaking capability, updated structure,quick trip and guide installation, competitive price,excellent and safe performance,beautiful and compact appearance, etc .

Mounting Requirements:

1. Circumstance temperature -5°C ~ +40°C, average temperature not exceeding 35°C.
2. Altitude above sea level less than 2000 m.
3. Humidity not exceeding 50% at 40°C and not exceeding 90% at 25°C.
4. Installation class II or III.
5. Pollution class 2.
6. Installation method DIN Rail mounting type.
7. The external magnetism shall not be more than 5 times of terrestrial one.
8. Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position.

Meba rccb and mcb MBL1210C

Technical Parameter:
-Rated residual non-operating current(Ino): 0.5 In
– 35mm wide for 2 pole Din Rail installation.
– Residual current off-time: 0.1s
– Standsrd: IEC1008/EN61008
– Minimum value of rated breaking capacity(lm): 630A
– Rated Voltage(Un): 2pole, 230V AC
– Rated conditional short-circuit capacity (lnc): 6KA
– Rated Current(In): 25, 40, 63A
– Rated residual operating current(In): 30, 100, 300, 500mA

Categories
Residual Current Circuit Breaker

Meba rccb breaker MBNT50L

Meba rccb breaker MBNT50L

Meba rccb breaker MBNT50L ,it has protective function as shortage as overload, and are used in lighting distribution system in dusty, commerce and dwelling, and protecting fractional electric motors, And they also have many merits of high protective grade (up to IP20), high break capacity, reliable sensitive action, convenient, multiple assembling, long life etc.

They are mainly adapted to the circuit of AC 50HZ, 230V in single pole, 400V in double, three, four poles for protecting overload and short circuit, Meanwhile, they are also used in turning on or off the electric apparatus and lighting circuit under the normal condition.

Meba rccb breaker MBNT50L

Technical Parameter:
Meba rccb breaker MBNT50L
MBNT50 MCB MBNT50L
Standard IEC60898 Number of pole 1P+N, 2P
Number of pole 1P+N, 2P Rated current(In) 6, 10,15,20,25,32
Rated current(In) 6,10,15,20, 25,32 Rated voltage(Un) 115/230V
Rated voltage (Un) 115/230V I n(mA) 10,15,30
Rated frequency B,C I n(mA) 5,7,5,15
Tripping curve ≥6000 times Tripping curve ≥6000 times
Electrical life 10000 times Electrical life 10000 times
Tropical ration Treatmen 2(RH95%, at 55℃) Im(A) 115V/1500, 230V/1000V
Protection degree IP20 Protection degree IP20
Categories
Residual Current Circuit Breaker With Over Current Protection

Meba residual current circuit breaker with overload protection rccb rcbo MB941

Meba residual current circuit breaker with overload protection rccb rcbo MB941 is the latest developed RCBO(residual current circuit breaker with overload protection), the function include leakage, overload and short circuit current. additional protection against direct contact(thanks to In=30A)

Meba residual current circuit breaker with overload protection rccb rcbo MB941

Technical Data
No. of Poles Type/Class Nominal Fault Current In mA Nominal Current In A Order Details Type Code
Icn=4.5kA,B characterisics
1P+N AC 30 10 MB941 B10-30MA AC
16 MB941 B16-30MA AC
20 MB941 B20-30MA AC
25 MB941 B25-30MA AC
Icn=4.5kA,C characterisics
1P+N AC 30 10 MB941 C10-30MA AC
16 MB941 C16-30MA AC
20 MB941 C20-30MA AC
25 MB941 C25-30MA AC
Icn=6kA,B characterisics
1P+N AC 30 10 MB951 B10-30MA AC
16 MB951 B16-30MA AC
20 MB951 B20-30MA AC
25 MB951 B25-30MA AC
Icn=6kA,C characteristics
1P+N AC 30 10 MB951 C10-30MA AC
16 MB951 C16-30MA AC
20 MB951 C20-30MA AC
25 MB951 C25-30MA AC
Categories
Miniature Circuit Breaker

Mcb rcd MB816C made by Meba

Meba mcb rcd MB816C adopts advanced design technology, it has protective function as shortage as overload, and are used in lighting distribution system industry, commerce and dwelling, and protecting fractional electric motors, and they also have many merits of high protective grade(up to IP20), high breaking capacity, reliable sensitive action, convenient, multiple assembling, long life etc. Meba mcb rcd MB816C are mainly adapted to the circuit of AC 50Hz, 230V in single pole; 400V in double, three, four poles for protecting overload and short circuit, meanwhile Meba mcb rcd MB816C are also used in turning on or off the electric apparatus and lighting circuit under the normal condition.

Meba mcb rcd MB816C

Technical parameters:

 

IEC 60898 IEC60947

Tropicalization

Relative Humidity

93% RH at 25℃

Room Temperature

-5℃ a 40℃

Electrical Properties

Rated at 40℃

A

6/10/16/20/25/32/40/50/63

Rated operating voltage at 40℃

Vac

240/415

Nominal Frequency

Hz

50/60

Interrupting Capacity at 230V

kA

6

Operating temperature

-5℃ a 40℃

Degree of Protection

IP20

Number of poles

1/2/3/4

Conductor cross section (minimum allowable)

mm2

25

Minimum number of power moves

6000

Minimum number of mechanical operations

20000

Operation curve

B/C/D

Current Trip Curve

A

5 a 10 In

Characteristic Intervention

attach

Type Of Assembly

FOR RIEL DIN 35 mm

Operation Indicator Window

The circuit breaker have an operating window color display that shows the state in which it is (connected or disconnected).

Features

MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current (Type C), 3 to 5 times rated current (Type B), 10 to 14 times rated current (Type D)

BIMETAL: ensures the breaker trip when overloaded.

ARC CHAMBER: effectively dissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit.

Present Certificates

CE CB

ISO 9001-2000 awarded by the competent certification body, Meba is qualified in the manufacturing of the object

IEC 60898 standards in the manufacture of the goods

Curve compliance issued Shot by an accredited laboratory for effect

Life, given by Meba to ensure that the life of the goods offered by at least 15 years.

Testing For Acceptance

Before receiving the circuit breakers(breakers), customers may perform the tests may be necessary to ensure compliance with the technical specifications.

Packing

The packaging is sure that withstand any adverse conditions during transport and handling to the warehouse of cutomers.

Dial Century, Year, Month and Batch

In one of its sides the breaker is marked with permanent ink, year, month and batch.

Catalog

Attach catalogs indicating the technical specification

Shows

Submit sample of the product offered

Technical Warranty

2 YEARS

Place of Delivery

CNF&FOB

Delivery

25 DAYS

Categories
Miniature Circuit Breaker

Meba mcb rccb GN type

Meba mcb rccb GN type  major export to South America, Middle East market, has light weight, small size, novel structure and excellent performance. They are mounted in the metal distribution board and used in guesthouses. block of fiats, high buildings, squares, airports, railway stations, plants and enterprises etc, in AC circuits 240V(single pole)up to 415V(3poie)50Hz for protection of overload short circuit and for circuit changeover in lighting system. Breaking capacity is 3KA. The items comply with BS&NEMA STANDARD.

Feature:

MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current (Type C), 3 to 5 times rated current ( Type B ), 10 to 20 times rated current ( Type D )

BIMETAL: ensures the breaker trip when overloaded.

ARC CHAMBER: effectively dissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit.

Meba mcb rccb GN type

Technical parameters

ropicalization Relative Humidity 93% RH at 25
Room Temperature 10 a 60
Electrical Properties Rated at 40 A 6/10/15/20/30/40/50/63
Rated operating voltage at 40 Vac 120/240/415
Nominal Frequency Hz 50/60
Interrupting Capacity at 230V kA 3
Operating temperature -5 a +40
Degree of Protection IP20
Number of poles 1,2,3,4
Conductor cross section (minimum allowable) mm2 25
Minimum number of power moves 4000
Minimum number of mechanical operations 6000
Operation curve B/C/D
Current Trip Curve A Type B 3a 5 In
Type C 5 a 10 In
Type D 10 a 14 In
Characteristic Intervention attach
Type Of Assembly NEMA Type
Features MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current (Type C), 10 to 14 times rated current ( Type D )
BIMETAL: ensures the breaker trip when overloaded.
ARC CHAMBER: effectively dissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit.