Categories
Residual Current Circuit Breaker

Meba Electrical Rccb RCD PF-2P

Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: OLL7-4
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 2P

Application:

1. OLL7-4, Residual Current Devices for earth leakage detection.

2. It is to be used in association with miniature circuit breakers, its function is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.

3. These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.

Merits:

Good quality , high breaking capability, updated structure,quick trip and guide installation, competitive price,excellent and safe performance,beautiful and compact appearance, etc .

Mounting Requirements:

1. Circumstance temperature -5°C ~ +40°C, average temperature not exceeding 35°C.
2. Altitude above sea level less than 2000 m.
3. Humidity not exceeding 50% at 40°C and not exceeding 90% at 25°C.
4. Installation class II or III.
5. Pollution class 2.
6. Installation method DIN Rail mounting type.
7. The external magnetism shall not be more than 5 times of terrestrial one.
8. Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position.

1. Electromagnetic and Electronic type
2. 35mm wide for 2 pole Din Rail installation.
3. Standsrd: IEC1008/EN61008
4. Rated Voltage(Un): 2pole, 230V AC
5. Rated Current(In): 25, 40, 63A
6. Rated residual operating current(I△n): 30, 100, 300, 500mA
7. Rated residual non-operating current(I△no): 0.5 I△n
8. Residual current off-time: ≤0.1s
9. Minimum value of rated breaking capacity(lm): 630A
10. Rated conditional short-circuit capacity (lnc): 10KA

Flexibilit:
With a wide range of currents and rated trip current available, the appropriate level of protection can be chosen for specific applications for either personnel or equipment protection.

Dimensions(mm):

[Download not found]Meba Electrical Rccb RCD PF-2P open a circuit automatically in the event of an earth fault between phase and earth and/or netural and earth.

Categories
Residual Current Circuit Breaker

Meba Residual Current Circuit Breaker CF-362

Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: CF-362
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 2P

Specification:

1. CF-362, Residual Current Devices for earth leakage detection. It is to be used in association with miniature circuit breakers.

2. Its function is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.

3. These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.

Merits:

Good quality , high breaking capability, updated structure,quick trip and guide installation, competitive price,excellent and safe performance,beautiful and compact appearance, etc .

1. Electromagnetic and Electronic type
2. 35mm wide for 2 pole Din Rail installation.
3. Standsrd: IEC1008/EN61008
4. Rated Voltage(Un): 2pole, 230V AC
5. Rated Current(In): 25, 40, 63A
6. Rated residual operating current(I△n): 30, 100, 300, 500mA
7. Rated residual non-operating current(I△no): 0.5 I△n
8. Residual current off-time: ≤0.1s
9. Minimum value of rated breaking capacity(lm): 630A
10. Rated conditional short-circuit capacity (lnc): 6KA

[Download not found] Meba Residual Current Circuit Breaker CF-362  is precise in structure, less elements, without auxiliary power and high working reliability.

Categories
Residual Current Circuit Breaker With Over Current Protection

Meba residual current circuit breakers with overcurrent protection RCBOs MB161

Meba residual current circuit breakers with overcurrent protection RCBOs MB161

Construction and Feature
– Provides protection against earth fault/leakage current, short-circuit and overload
– High short-circuit capacity
– Provides complementary protection against direct contact by human body
– Effectively protects electric equipmet against insulating failure
– Contact position indication
– Provides protection against over-voltage
– Provides comprehensive protection to household and commercial distribution systems

Meba residual current circuit breakers with overcurrent protection RCBOs MB161

Technical Data
– Type: Electro-magnetic type
– Residual current characteristics: AC
– Pole NO.: 1P+N
– Tripping curve: B, C
– Rated short-circuit capacity: 10kA
– Rated current(A): 6, 10, 16, 20, 25, 32
– Rated voltage: 230/240V AC
– Rated frequency: 50/60Hz
– Rated residual operating current(mA): 0.03, 0.1
– Tripping duration: instantaneous ≤0.1s
– Electro-mechanical endurance: 4000 cycles
– Connection terminal: pillar terminal with clampWiring Diagram

Overall & Installation Dimensions

Categories
Residual Current Circuit Breaker With Over Current Protection

Meba residual current circuit breaker with overload protection electrical rcbo MBB1

Meba residual current circuit breaker with overload protection electrical rcbo MBB1

is Electronic Type, used for AC 50HZ or 60HZ, single pole and two poles 230V; three poles and four poles 400V, rated current is up to 40A. It can automatically and immediately cut off power supply once someone suffers from electric shock or leakage current above specified value. It can effectively protect personal security and avoid the damage to equipments. This RCBO can also function as overload and short-circuit protection and un-frequent changeover of line under normal condition.
It is suitable for industry, business, building and residence, etc.
The product is conformity with GB16917.1, IEC61009-1 standards.

Meba residual current circuit breaker with overload protection electrical rcbo MBB1

Techincal Data
1. Rated current: 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A.
2. Rated residual operating current: 0.01A, 0.03A.
3. Tripping characteristics: C.
4. Icn: 6000A
5. Rated residual current operated making and breaking capacity Im: 500A
6. Rated residual non-operated current: Ino: 0.5InOverall and Mounting DimensionsDimensions B(mm)

1 pole 2 pole 3 pole 4 pole
54 72 117 135

Meba residual current circuit breaker with overload protection electrical rcbo MBB1

Techincal Data
1. Rated current: 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A.
2. Rated residual operating current: 0.01A, 0.03A.
3. Tripping characteristics: C.
4. Icn: 6000A
5. Rated residual current operated making and breaking capacity Im: 500A
6. Rated residual non-operated current: Ino: 0.5InOverall and Mounting DimensionsDimensions B(mm)

1 pole 2 pole 3 pole 4 pole
54 72 117 135