Categories
Fixed Professional Light

Meba-anti dazzle passageway light-ZY8100

Application

Meba-anti dazzle passageway light-ZY8100 is widely applicable to the floodlighting of the roads or passages for the plants, stations, large facilities, stadiums, tunnels and bridges.
Technical Data

 

1. Voltage/Hz  AC220V  50Hz
2. Light source
MH    Watts70W / 150W
Luminous flux 5500lm / 13000lm
Life cycle 9000 h
HPS   Watts 70W / 100W / 150W
Luminous flux 6000 lm / 9600 lm / 16000 lm
Life cycle 27500h
3. Cable outer dia φ6~φ8mm
4. Dimension 340×270×208mm
5. Net weight 6.2kg

6.Gross weight 7.1Kg
6. Shell protection grade IP65
7. Corrosion-proof grade WF2

1. ZY8100 lighting source and electrical components are of famous brands from Germany, with power factor > 0.9, long service life, reliable performance, good light transmission, and brightness 1020 higher than those with same power.

2. By means of the protection angle design, it can prevent the dazzling light, reduce the irritation to the eyes of operators and avoid discomfort and weariness.

3. With multi-layer shock-proof structure design and high intensity alloy shell, it is guaranteed for long-time and safe operation under high frequency shocking environments like the roadbed, track or tunnel.

4. Special seal and surface coating keep the lamp from corrosion or rusting under very harsh conditions of great moisture or high temperature.

[Download not found]
Categories
Terminal Block

Meba Connection terminal Box MBT411

TECHNICAL DATA
• Rated insulation voltage 500V
• Fixed on DIN rail or on panel with 2 screws
• Insulated screen for each brass bar
• Offset realization of the feed-in holes to permit an easier wiring of the conductors
• PA,Polyamide66,94-2 grade,inflaming retarding, working
• Tempertaure:-30 °C to110  °C
• Voltage:250-450

MATERIALS
• Brass
• Iron screws
• Plastic body: Polycarbonate V0 according to UL94

COMPLYING WITH STANDARDS
• Conformity to standard EN 60947-1

DETAILS
• Releasing device adopted on all the bars
• Possibility of removing all the bars for an easy wiring

Advantages:
1) High precision
2) Excellent inoxidability
3) Great ingredient accuracy and high intensity
4) High corrosion resistance
5) Our own mold workshop and injection molding workshop
6) OEM Service
7) Prompt Delivery
8) Small Order Accept
9) Tolerance: ± 0.3mm
10) Certificate: CE&RoHS&OTHERS
11) Free sample

All products that we supplied  have  the feature of safety, reliable, convenient and cheaper in price. Good in power conductor, lower in contact resistance, full range of specification. Customer  satisfaction is our greatest pursuit !

Item No. Bus Bar Spec. No. Of Bus Bar Conductors with starfix temules
X-section(mm²)
Cond. wout ferr.
X-section(mm²)
Dimensions(L*W*H)(mm)
MBT207 5* Φ 5.3mm
2* Φ 7.5mm
2 1.5 to 6
6 to 16
2.5 to 6
10 to 25
65*42*50
MBT211 7* Φ 5.3mm
2* Φ 7.5mm
2* Φ 9mm
2 1.5 to 6
6 to 16
10 to 16
2.5 to 6
10 to 25
10 to 35
100*42*50
MBT215 11* Φ 5.3mm
2* Φ 7.5mm
2* Φ 9mm
2 1.5 to 6
6 to 16
10 to 16
2.5 to 6
10 to 25
10 to 35
135*42*50
MBT407 5* Φ 5.3mm
2* Φ 7.5mm
4 1.5 to 6
6 to 16
2.5 to 6
10 to 25
65*85*50
MBT411 7* Φ 5.3mm
2* Φ 7.5mm
2* Φ 9mm
4 1.5 to 6
6 to 16
10 to 16
2.5 to 6
10 to 25
10 to 35
100*85*50
MBT415 11* Φ 5.3mm
2* Φ 7.5mm
2* Φ 9mm
4 1.5 to 6
6 to 16
10 to 16
2.5 to 6
10 to 25
10 to 35
135*85*50

Meba Connection terminal Box MBT411 feature of safety, reliable, convenient and cheaper in price. Good in power conductor, lower in contact resistance, full range of specification.

Categories
Residual Current Circuit Breaker

Meba residual current circuit MB3410C

Meba residual current circuit  MB3410C

Meba residual current circuit  MB3410C , It is to be used in association with miniature circuit breakers, its function is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application. These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.

Application:

1. MB3410, Residual Current Devices for earth leakage detection.

2. It is to be used in association with miniature circuit breakers, its function is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.

3. These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.

Merits:

Good quality , high breaking capability, updated structure,quick trip and guide installation, competitive price,excellent and safe performance,beautiful and compact appearance, etc .

Mounting Requirements:

1. Circumstance temperature -5°C ~ +40°C, average temperature not exceeding 35°C.
2. Altitude above sea level less than 2000 m.
3. Humidity not exceeding 50% at 40°C and not exceeding 90% at 25°C.
4. Installation class II or III.
5. Pollution class 2.
6. Installation method DIN Rail mounting type.
7. The external magnetism shall not be more than 5 times of terrestrial one.
8. Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position.

[tab_item title=”Parameter”]

Meba residual current circuit  MB3410C

Technical Parameter:
1. Electromagnetic and Electronic type
2. 70mm wide for 4 pole Din Rail installation.
3. Standsrd: IEC1008/EN61008
4. Rated Voltage(Un): 4pole, 400V AC
5. Rated Current(In): 25, 40, 63A
6. Rated residual operating current(I△n): 30, 100, 300, 500mA
7. Rated residual non-operating current(I△no): 0.5 In
8. Residual current off-time: ≤0.1s
9. Minimum value of rated breaking capacity(lm): 630A
10. Rated conditional short-circuit capacity (lnc): 6KA
Categories
Residual Current Circuit Breaker

Meba residual current circuit breaker MB64

Meba residual current circuit breaker MB64

Meba residual current circuit breaker MB64 , It is to be used in association with miniature circuit breakers, its function is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application. These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.

Application:

1. MB64, Residual Current Devices for earth leakage detection.

2. It is to be used in association with miniature circuit breakers, its function is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.

3. These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.

Merits:

Good quality , high breaking capability, updated structure,quick trip and guide installation, competitive price,excellent and safe performance,beautiful and compact appearance, etc .

Mounting Requirements:

1. Circumstance temperature -5°C ~ +40°C, average temperature not exceeding 35°C.
2. Altitude above sea level less than 2000 m.
3. Humidity not exceeding 50% at 40°C and not exceeding 90% at 25°C.
4. Installation class II or III.
5. Pollution class 2.
6. Installation method DIN Rail mounting type.
7. The external magnetism shall not be more than 5 times of terrestrial one.
8. Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position.

[tab_item title=”Parameter”]

Meba residual current circuit breaker MB64

Technical Parameter:
1. Electromagnetic and Electronic type
2. 70mm wide for 4 pole Din Rail installation.
3. Standsrd: IEC1008/EN61008
4. Rated Voltage(Un): 4pole, 400V AC
5. Rated Current(In): 25, 40, 63A
6. Rated residual operating current(In): 30, 100, 300, 500mA
7. Rated residual non-operating current(Ino): 0.5 In
8. Residual current off-time: 0.1s
9. Minimum value of rated breaking capacity(lm): 630A
10. Rated conditional short-circuit capacity (lnc): 6KA

 

Categories
Residual Current Circuit Breaker

Meba rccb MB62

Meba rccb MB62

Meba rccb MB62 ,Residual Cur rent Devices for earth leakage detection. It is to be used in association with miniature circuit breakers, its function is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application. These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.

Application:

1. MB64, Residual Current Devices for earth leakage detection.

2. It is to be used in association with miniature circuit breakers, its function is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.

3. These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.

Merits:

Good quality , high breaking capability, updated structure,quick trip and guide installation, competitive price,excellent and safe performance,beautiful and compact appearance, etc .

Mounting Requirements:

1. Circumstance temperature -5°C ~ +40°C, average temperature not exceeding 35°C.
2. Altitude above sea level less than 2000 m.
3. Humidity not exceeding 50% at 40°C and not exceeding 90% at 25°C.
4. Installation class II or III.
5. Pollution class 2.
6. Installation method DIN Rail mounting type.
7. The external magnetism shall not be more than 5 times of terrestrial one.
8. Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position.

[tab_item title=”Parameter”]

Meba rccb MB62

Technical Parameter:
– Electromagnetic and Electronic type
– Rated residual non-operating current(Ino): 0.5 In
– 35mm wide for 2 pole Din Rail installation.
– Residual current off-time: 0.1s
– Standsrd: IEC1008/EN61008
– Minimum value of rated breaking capacity(lm): 630A
– Rated Voltage(Un): 2pole, 230V AC
– Rated conditional short-circuit capacity (lnc): 6KA
– Rated Current(In): 25, 40, 63A
– Rated residual operating current(In): 30, 100, 300, 500mA
Categories
Metal Distribution Board

TS Metal Box Stainless Steel Distribution Box

1. Designed to enclose electrical and or electronic equipment and protect against harsh,industrial environments.

2. For use as instrument enclosures,electric hydraulic or pneumatic control housings,electrical junction boxes or terminal wiring enclosures.

3. Impressive styling features make the enclosure a suitable addition to any high-tech equipment installation

4. For high temperature applications ,a gasket retainer may be required, please refer to factory

5. Single door, IP65 weather proof metal box ,Many sizes for your selecting
Construction:

1. Body and cover are formed from 1.2mm mild steel. mounting plate in sheet  steal or galvanized steel.

2. Continuously hinged cover has steel hinges and provides 120 º opening.

H W D Thickness
mm mm mm Door/mm Body/mm M.P/mm
200 200 150 1.2 1.2 2
250 200 150 1.2 1.2 2
300 200 150 1.2 1.2 2
300 200 200 1.2 1.2 2
300 250 150 1.2 1.2 2
300 250 200 1.2 1.2 2
300 250 250 1.2 1.2 2
300 300 150 1.2 1.2 2
300 300 200 1.2 1.2 2
300 300 250 1.2 1.2 2
400 300 150 1.2 1.2 2
400 300 200 1.2 1.2 2
400 300 250 1.2 1.2 2
400 300 300 1.2 1.2 2
400 400 150 1.2 1.2 2
400 400 200 1.2 1.2 2
400 400 250 1.2 1.2 2
400 400 300 1.2 1.2 2
500 300 150 1.2 1.2 2
500 300 200 1.2 1.2 2
500 300 250 1.2 1.2 2
500 300 300 1.2 1.2 2
500 400 150 1.2 1.2 2
500 400 200 1.2 1.2 2
500 400 250 1.2 1.2 2
500 400 300 1.2 1.2 2
500 500 150 1.2 1.2 2
500 500 200 1.2 1.2 2
500 500 250 1.2 1.2 2
500 500 300 1.2 1.2 2
600 400 150 1.2 1.2 2
600 400 200 1.2 1.2 2
600 400 250 1.2 1.2 2
600 400 300 1.2 1.2 2
600 500 150 1.2 1.2 2
600 500 200 1.2 1.2 2
600 500 250 1.2 1.2 2
600 500 300 1.2 1.2 2
600 600 150 1.2 1.2 2
600 600 200 1.2 1.2 2
600 600 250 1.2 1.2 2
600 600 300 1.2 1.2 2
700 400 200 1.2 1.2 2
700 400 300 1.2 1.2 2
700 500 150 1.2 1.2 2
700 500 200 1.2 1.2 2
700 500 250 1.2 1.2 2
700 500 300 1.2 1.2 2
700 600 200 1.2 1.2 2
700 600 250 1.2 1.2 2
700 600 300 1.2 1.2 2
800 600 200 1.5 1.5 2
800 600 250 1.5 1.5 2
800 600 300 1.5 1.5 2
800 600 400 1.5 1.5 2
800 800 200 1.5 1.5 2
800 800 250 1.5 1.5 2
800 800 300 1.5 1.5 2
1000 600 200 1.5 1.5 2
1000 600 250 1.5 1.5 2
1000 600 300 1.5 1.5 2
1000 700 200 1.5 1.5 2
1000 800 200 1.5 1.5 2
1000 800 250 1.5 1.5 2
1000 800 300 1.5 1.5 2
1000 800 400 1.5 1.5 2
1000 1000 250 1.5 1.5 2
1000 1000 300 1.5 1.5 2
1200 600 200 1.5 1.5 2
1200 600 250 1.5 1.5 2
1200 600 300 1.5 1.5 2
1200 800 200 1.5 1.5 2
1200 800 250 1.5 1.5 2
1200 800 300 1.5 1.5 2
1200 1000 250 1.5 1.5 2
1200 1000 300 1.5 1.5 2
1200 1000 400 1.5 1.5 2
1200 1200 250 1.5 1.5 2
1200 1200 300 1.5 1.5 2
1400 600 300 1.5 1.5 2
1400 800 300 1.5 1.5 2
1400 800 400 1.5 1.5 2
1400 1000 300 1.5 1.5 2
1400 1000 400 1.5 1.5 2
1400 1200 300 1.5 1.5 2

[Download not found] TS Metal Box Stainless Steel Distribution Box Wider enclosure offers ease or wiring and move heat dissipation.

Categories
Metal Distribution Board

Meba Double doors enclosure manufacturer MBTS-5

1.Designed for safe,reliable distribution and control of electrical power as service entrance equipment in residential,commercial and light industrial installations.

2.Electrical enclosure protect against harsh,industrial envirenments.

3.For use as instrument enclosure,electric, hydraulic or pneumatic control housings,electrical junction boxes

4. For high temperature applications ,a gasket retainer may be required, please refer to factory

5. Single door, IP65 weather proof metal box ,Many sizes for your selecting

6. For use as instrument enclosures,electric hydraulic or pneumatic control housings,electrical junction boxes or terminal wiring enclosures.

7.Impressive styling features make the enclosure a suitable addition to any high-tech equipment installation.

8. Impressive styling features make the enclosure a suitable addition to any high-tech equipment installation
Construction:

1. Body and cover are formed from 1.2mm mild steel. mounting plate in sheet  steal or galvanized steel.

2. Continuously hinged cover has steel hinges and provides 120 º opening.

 Plexiglass Door+Inner Door

Model

H (mm)

W(mm)

D(mm)

MBTS-5 404020

400

400

200

MBTS-5 503015

500

300

150

MBTS-5 503020

500

300

200

MBTS-5 503025

500

300

250

MBTS-5 504015

500

400

150

MBTS-5 504020

500

400

200

MBTS-5 504025

500

400

250

MBTS-5 504030

500

400

300

MBTS-5 505020

500

500

200

MBTS-5 604015

600

400

150

MBTS-5 604020

600

400

200

MBTS-5 604025

600

400

250

MBTS-5 605015

600

500

150

MBTS-5 605020

600

500

200

MBTS-5 605025

600

500

250

MBTS-5 606025

600

600

250

MBTS-5 606030

600

600

300

MBTS-5 705020

700

500

200

MBTS-5 705025

700

500

250

MBTS-5 705030

700

500

300

MBTS-5 806020

800

600

200

MBTS-5 806025

800

600

250

MBTS-5 806030

800

600

300

MBTS-5 808020

800

800

200

MBTS-5 808030

800

800

300

MBTS-5 1006025

1000

600

250

MBTS-5 1000630

1000

600

300

MBTS-5 1008025

1000

800

250

MBTS-5 1008030

1000

800

300

MBTS-5 10010030

1000

1000

300

MBTS-5 1208030

1200

800

300

 

 

 

 

Meba Double doors enclosure manufacturer MBTS-5  wider enclosure offers ease or wiring and move heat dissipation.

Categories
Residual Current Circuit Breaker

Meba elcb MBL1410C

Meba elcb MBL1410C

Meba elcb MBL1410C ,Residual Cur rent Devices for earth leakage detection. It is to be used in association with miniature circuit breakers, its function is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application. These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.

Application:

1. MB64, Residual Current Devices for earth leakage detection.

2. It is to be used in association with miniature circuit breakers, its function is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.

3. These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.

Merits:

Good quality , high breaking capability, updated structure,quick trip and guide installation, competitive price,excellent and safe performance,beautiful and compact appearance, etc .

Mounting Requirements:

1. Circumstance temperature -5°C ~ +40°C, average temperature not exceeding 35°C.
2. Altitude above sea level less than 2000 m.
3. Humidity not exceeding 50% at 40°C and not exceeding 90% at 25°C.
4. Installation class II or III.
5. Pollution class 2.
6. Installation method DIN Rail mounting type.
7. The external magnetism shall not be more than 5 times of terrestrial one.
8. Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position.

Meba elcb MBL1410C

Technical Parameter:
– Electromagnetic and Electronic type
– Rated residual non-operating current(Ino): 0.5 In
– 35mm wide for 2 pole Din Rail installation.
– Residual current off-time: 0.1s
– Standsrd: IEC1008/EN61008
– Minimum value of rated breaking capacity(lm): 630A
– Rated Voltage(Un): 2pole, 230V AC
– Rated conditional short-circuit capacity (lnc): 6KA
– Rated Current(In): 25, 40, 63A
– Rated residual operating current(In): 30, 100, 300, 500mA
Categories
Residual Current Circuit Breaker

Meba rccb and mcb MBL1210C

Meba rccb and mcb MBL1210C

Meba rccb and mcb MBL1210C

has introduced the F200 Ground Fault Equipment Protector (GFEP), designed to protect equipment against damaging line-to-ground currents by disconnecting all ungrounded conductors of the faulted circuit. A ground fault is caused by an insulation loss between a live conductor and an exposed conductive part that creates a flow of current to the ground. Most short circuits initially manifest as ground faults, which, if undetected, can cause serious and costly damage to electrical systems and equipment. An  F200 GFEP added to an electrical system trips when the system leaks a significant current to ground, immediately preventing the potential short circuit before such damage can occur.

The MEBA F200 GFEP line consists of the 2-pole F202 for single phase networks, and the 4-pole F204 for split phases, Delta and Wye networks.  The F200 GFEP immediately detects ground faults by continuously measures the current balance between live conductors and the neutral using a toroidal current transformer.

Application:

1. MBL1210C, Residual Current Devices for earth leakage detection.

2. It is to be used in association with miniature circuit breakers, its function is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.

3. These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.

Merits:

Good quality , high breaking capability, updated structure,quick trip and guide installation, competitive price,excellent and safe performance,beautiful and compact appearance, etc .

Mounting Requirements:

1. Circumstance temperature -5°C ~ +40°C, average temperature not exceeding 35°C.
2. Altitude above sea level less than 2000 m.
3. Humidity not exceeding 50% at 40°C and not exceeding 90% at 25°C.
4. Installation class II or III.
5. Pollution class 2.
6. Installation method DIN Rail mounting type.
7. The external magnetism shall not be more than 5 times of terrestrial one.
8. Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position.

Meba rccb and mcb MBL1210C

Technical Parameter:
-Rated residual non-operating current(Ino): 0.5 In
– 35mm wide for 2 pole Din Rail installation.
– Residual current off-time: 0.1s
– Standsrd: IEC1008/EN61008
– Minimum value of rated breaking capacity(lm): 630A
– Rated Voltage(Un): 2pole, 230V AC
– Rated conditional short-circuit capacity (lnc): 6KA
– Rated Current(In): 25, 40, 63A
– Rated residual operating current(In): 30, 100, 300, 500mA

Categories
Residual Current Circuit Breaker

Meba elcb and rccb MBL226C

 Meba elcb and rccb MBL226C for earth leakage detection. It is to be used in association with miniature circuit breakers, its function is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application. These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.

Application:

1. MB64, Residual Current Devices for earth leakage detection.

2. It is to be used in association with miniature circuit breakers, its function is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.

3. These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.

Merits:

Good quality , high breaking capability, updated structure,quick trip and guide installation, competitive price,excellent and safe performance,beautiful and compact appearance, etc .

Mounting Requirements:

1. Circumstance temperature -5°C ~ +40°C, average temperature not exceeding 35°C.
2. Altitude above sea level less than 2000 m.
3. Humidity not exceeding 50% at 40°C and not exceeding 90% at 25°C.
4. Installation class II or III.
5. Pollution class 2.
6. Installation method DIN Rail mounting type.
7. The external magnetism shall not be more than 5 times of terrestrial one.
8. Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position.

Meba elcb and rccb MBL226C

Products purpose:

1.For protection against risk of fire due to live to earth fault where fault current is in sufficient to cause over-current protection device to operate.

2.For protection against risk of shock from indirect contact with equipment suffering a live to earth fault.

3.For protection against shock in potentially hazardous environment.

As supplementary protection against shock from directly touching live parts.

Note:an RCCB must not be used as the sole means of protection against touching live parts.

sensed

AC,A

Rated sensitivity lΔn

0.03A,0.1A,0.3A

Rated residual making and breaking capacity lΔm

500(ln=25A/40A)630(ln=63A)

Short-circuit current lΔc

6000/10000A

Break time under lΔn

≤0.1s

Rated impulse withstand voltage(1.2/50)Uimp

6000V

Dielectric test voltage at ind.Freq.for 1min

2.5kV

Electrical life

2000t

Mechanical life

2000t

Fault current indicator

Yes

Protection degree

lP20

Ambient temperature(with daily average≤35°c)

-5~+40°c

Storage temperature

-25~+70°c

Terminal connection type

Cable/Pin-type bus bar

Terminal size top/bottom for cable

25mm²

18-3AWG

Terminal size top/bottom for bus bar

25mm²

18-3AWG

Tightening torque

2.5N*m

22ln-lbsm

Mounting

On DIN rail EN  60715(35mm)by means of fast clip device

Connection

From top and bottom

Categories
Residual Current Circuit Breaker

Meba rccb breaker MBNT50L

Meba rccb breaker MBNT50L

Meba rccb breaker MBNT50L ,it has protective function as shortage as overload, and are used in lighting distribution system in dusty, commerce and dwelling, and protecting fractional electric motors, And they also have many merits of high protective grade (up to IP20), high break capacity, reliable sensitive action, convenient, multiple assembling, long life etc.

They are mainly adapted to the circuit of AC 50HZ, 230V in single pole, 400V in double, three, four poles for protecting overload and short circuit, Meanwhile, they are also used in turning on or off the electric apparatus and lighting circuit under the normal condition.

Meba rccb breaker MBNT50L

Technical Parameter:
Meba rccb breaker MBNT50L
MBNT50 MCB MBNT50L
Standard IEC60898 Number of pole 1P+N, 2P
Number of pole 1P+N, 2P Rated current(In) 6, 10,15,20,25,32
Rated current(In) 6,10,15,20, 25,32 Rated voltage(Un) 115/230V
Rated voltage (Un) 115/230V I n(mA) 10,15,30
Rated frequency B,C I n(mA) 5,7,5,15
Tripping curve ≥6000 times Tripping curve ≥6000 times
Electrical life 10000 times Electrical life 10000 times
Tropical ration Treatmen 2(RH95%, at 55℃) Im(A) 115V/1500, 230V/1000V
Protection degree IP20 Protection degree IP20
Categories
Residual Current Circuit Breaker

Meba elcb circuit breaker MBNT50LB

Meba elcb circuit breaker MBNT50LB

Meba elcb circuit breaker MBNT50LB,it has protective function as shortage as overload, and are used in lighting distribution system in dusty, commerce and dwelling, and protecting fractional electric motors, And they also have many merits of high protective grade (up to IP20), high break capacity, reliable sensitive action, convenient, multiple assembling, long life etc.

They are mainly adapted to the circuit of AC 50HZ, 230V in single pole, 400V in double, three, four poles for protecting overload and short circuit, Meanwhile, they are also used in turning on or off the electric apparatus and lighting circuit under the normal condition.

Meba elcb circuit breaker MBNT50LB

Technical Parameter:
Meba elcb circuit breaker MBNT50LB
MBNT50 MCB MBNT50LB
Standard IEC60898 Number of pole 1P+N, 2P
Number of pole 1P+N, 2P Rated current(In) 6, 10,15,20,25,32
Rated current(In) 6,10,15,20, 25,32 Rated voltage(Un) 115/230V
Rated voltage (Un) 115/230V I n(mA) 10,15,30
Rated frequency B,C I n(mA) 5,7,5,15
Tripping curve ≥6000 times Tripping curve ≥6000 times
Electrical life 10000 times Electrical life 10000 times
Tropical ration Treatmen 2(RH95%, at 55℃) Im(A) 115V/1500, 230V/1000V
Protection degree IP20 Protection degree IP20
Categories
Magnetic AC Contactor

Meba Magnetic Contactor MBMW-9MB

Meba Magnetic Contactor MBMW-9MB

Meba Magnetic Contactor MBMW-9MB is an electrically controlled switch used for switching a power circuit, similar to a relay except with higher current ratings. This  contactor is controlled by a circuit which has a much lower power level than the switched circuit.

The Contactors come in many forms with varying capacities and features. Unlike a circuit breaker, this contactor is not intended to interrupt a short circuit current. The Contactors range from those having a breaking current of several amperes to thousands of amperes and 24 V DC to many kilovolts. The physical size of contactors ranges from a device small enough to pick up with one hand, to large devices approximately a meter (yard) on a side.

The Contactors are used to control electric motors, lighting, heating, capacitor banks, thermal evaporators, and other electrical loads.

Meba Magnetic Contactor MBMW-9MB

Technical Parameter:
Meba Magnetic Contactor MBMW-9MB

Type

Rated ultimte

Rated current

AC1 duty

Single-phase moter

AC3 duty

AC3 duty

110V

220V

200V-220V

380V-440V

500V-550V

200V-220V

380V-440V

500V-550V

A

MBMW-9MB

0.4

0.8

2.5

4

4

11

9

7

25

MBMW-12MB

0.5

1

3.5

5.5

7.5

13

12

12

25

MBMW-18MB

0.75

1.5

4.5

7.5

7.5

18

18

13

40

MBMW-22MB

0.9

1.8

5.5

11

15

22

22

22

40

MBMW-32MB

1.2

7.5

15

18.5

32

32

28

50

MBMW-40MB

1.7

11

18.5

22

40

40

32

60

MBMW-50MB

15

22

30

55

50

43

80

MBMW-65MB

18.5

30

33

65

65

60

100

MBMW-75MB

22

37

37

75

75

64

110

MBMW-85MB

25

45

45

85

85

75

135

Type

Rated power(KW)

Rated current

AC1 duty

1pole motor

AC3 duly

AC3 duty

Without PB

Push button type

110V

220V

200V-220V

380V-440V

500V-550V

200V-220V

380V-440V

500V-550V

A

MBMW-9

MBMW-9B

0.4

0.8

2.5

4

4

11

9

7

20

MBMW-12

MBMW-12B

0.5

1

3.5

5.5

7.5

12

12

12

20

MBMW-18

MBMW-18B

0.75

1.5

4.5

7.5

7.5

18

18

13

25

MBMW-22M

MBMW-22B

0.9

1.8

5.5

11

15

22

22

22

32

Categories
Magnetic AC Contactor

Meba Magnetic Motor Starter MBMW-9B

Meba Magnetic Motor Starter MBMW-9B

Meba Magnetic Motor Starter MBMW-9B is mainly applied to circuit of AC 50 or 60HZ, voltage up to 550V for far distance making and breaking circuit and frequently starting and controlling motor. It has the features of small volume, light weight, safe and reliable performance etc.

Meba Magnetic Motor Starter MBMW-9B

Technical Parameter:
Meba Magnetic Motor Starter MBMW-9B

Type

Rated ultimte

Rated current

AC1 duty

Single-phase moter

AC3 duty

AC3 duty

110V

220V

200V-220V

380V-440V

500V-550V

200V-220V

380V-440V

500V-550V

A

MBMW-9MB

0.4

0.8

2.5

4

4

11

9

7

25

MBMW-12MB

0.5

1

3.5

5.5

7.5

13

12

12

25

MBMW-18MB

0.75

1.5

4.5

7.5

7.5

18

18

13

40

MBMW-22MB

0.9

1.8

5.5

11

15

22

22

22

40

MBMW-32MB

1.2

7.5

15

18.5

32

32

28

50

MBMW-40MB

1.7

11

18.5

22

40

40

32

60

MBMW-50MB

15

22

30

55

50

43

80

MBMW-65MB

18.5

30

33

65

65

60

100

MBMW-75MB

22

37

37

75

75

64

110

MBMW-85MB

25

45

45

85

85

75

135

Type

Rated power(KW)

Rated current

AC1 duty

1pole motor

AC3 duly

AC3 duty

Without PB

Push button type

110V

220V

200V-220V

380V-440V

500V-550V

200V-220V

380V-440V

500V-550V

A

MBMW-9

MBMW-9B

0.4

0.8

2.5

4

4

11

9

7

20

MBMW-12

MBMW-12B

0.5

1

3.5

5.5

7.5

12

12

12

20

MBMW-18

MBMW-18B

0.75

1.5

4.5

7.5

7.5

18

18

13

25

MBMW-22M

MBMW-22B

0.9

1.8

5.5

11

15

22

22

22

32

 

Categories
Metal Distribution Board

Meba distribution panels electrical distribution design surface 8way MBM-8

1.Designed for safe,reliable distribution and control of electrical power as service entrance equipment in residential,commercial and light industrial installations.

2.They are available in plug in , din rail designs for indoor and outdoor applications and also available with main as MCB,isolator MCCB or MCB.

3. Impressive styling features make the enclosure a suitable addition to any high-tech equipment installation

4. For high temperature applications ,a gasket retainer may be required, please refer to factory

5. Single door, IP65 weather proof metal box ,Many sizes for your selecting

6. For use as instrument enclosures,electric hydraulic or pneumatic control housings,electrical junction boxes or terminal wiring enclosures.
Construction:

1. Body and cover are formed from 1.2mm mild steel. mounting plate in sheet  steal or galvanized steel.

2. Continuously hinged cover has steel hinges and provides 120 º opening.

Molde

Type

Phase

Ways

Main Switch

surface

Plug-in

Single

4,6,8,10,12

ELCB, Isolator ELCB+Isolator

Single Phase

H

W

D

E

F

4WAY

228

210

90

218

200

6WAY

279

210

90

269

200

8WAY

330

210

90

320

200

10WAY

381

210

90

381

200

12WAY

432

210

90

422

200

Dimension:

MBM-4 Dimension

 

Meba distribution panels electrical distribution design surface 8way MBM-8 wider enclosure offers ease or wiring and move heat dissipation.

Categories
Magnetic Starter Or Motor Starter

Meba Motor Starter MBE1-D09

Meba Motor Starter MBE1-D09

Meba Motor Starter MBE1-D09 is mainly applied to circuit of AC 50 or 60HZ, voltage up to 550V for far distance making and breaking circuit and frequently starting and controlling motor. It has the features of small volume, light weight, safe and reliable performance etc.

Meba Motor Starter MBE1-D09

Technical Parameter:
Meba Motor Starter MBE1-D09

Specifications

Product mode No.and specificatiol LE1-09 and 12 Double in sulated,protected to IP429(3) or IP659(4)
Enclosure LE1-18 and 25 Double in sulated,protected to IP427(3) or IP557(4)
LE1-32 ~ 95 Metal, IP55 to IP559
Control(2 push buttons moufited on enclosure cover) LE1-09 ~ 95 1 Green start button ’I’, ‘I’ Red stop/Teset buttion “O”
Connections LE1-09 ~ 95 Electricol power and control recircuit connections

 

LE1-D AC telemecanique magnetic motor starter switch

Standard control circuit voltages

Volts 24 42 48 110 220/230 230 240 380/400 400 415 440
50/60Hz B7 D7 E7 F7 M7 P7 U7 Q7 V7 N7 R7

 

LE1-D AC telemecanique magnetic motor starter switch

Maximum power AC3 duty(KW) Rated current (A) Type of enclosure Code number Suitable thermal relay
220V 230V 380V 400V 415V 440V 500V 660V 690V Long Life Normal life
2.2 4 4 4 4 4 9 IP42
IP65
LE1-D094
LE1-D093
LR2 D1312
LR2 D1314
3 5.5 5.5 5.5 5.5 5.5 12 IP45
IP55
LE1-D124
LE1-D123
LE1-D094
LE1-D093
LR2 D1316
4 7.5 9 9 10 10 18 IP42
IP55
LE1-D188
LE1-D185
LE1-D124
LE1-D123
LR2 D1321
5.5 11 11 11 15 15 25 IP42
IP55
LE1-D258
LE1-D255
LE1-D188
LE1-D185
LR2 D1322
LR2 D2353
7.5 15 15 15 18.5 18.5 32 IP55 LE1-D325 LE1-D258
LE1-D255
LR2 D2355
11 18.5 22 22 22 30 40 IP55 LE1-D405 LE1-D325 LR2 D3353
LR2 D3355
15 22 25 30 30 33 50 IP55 LE1-D505 LE1-D405 LR2 D3357
LR2 D3359
18.5 30 37 37 37 37 65 IP55 LE1-D655 LE1-D505 LR2 D3361
22 37 45 45 55 45 80 IP55 LE1-D805 LE1-D655 LR2 D3363
LR2 D3365
25 45 45 45 55 45 95 IP55 LE1-D955 LE1-D805 LR2 D3365
Categories
Magnetic Starter Or Motor Starter

Meba Magnetic Starter MBE1-25

Meba Magnetic Starter MBE1-25

Meba Magnetic Starter MBE1-25  is mainly applied to circuit of AC 50 or 60HZ, voltage up to 550V for far distance making and breaking circuit and frequently starting and controlling motor. It has the features of small volume, light weight, safe and reliable performance etc.

Meba Magnetic Starter MBE1-25

Technical Parameter:
Meba Magnetic Starter MBE1-25

Specifications

Product mode No.and specificatiol LE1-09 and 12 Double in sulated,protected to IP429(3) or IP659(4)
Enclosure LE1-18 and 25 Double in sulated,protected to IP427(3) or IP557(4)
LE1-32 ~ 95 Metal, IP55 to IP559
Control(2 push buttons moufited on enclosure cover) LE1-09 ~ 95 1 Green start button ’I’, ‘I’ Red stop/Teset buttion “O”
Connections LE1-09 ~ 95 Electricol power and control recircuit connections

 

LE1-D AC telemecanique magnetic motor starter switch

Standard control circuit voltages

Volts 24 42 48 110 220/230 230 240 380/400 400 415 440
50/60Hz B7 D7 E7 F7 M7 P7 U7 Q7 V7 N7 R7

 

LE1-D AC telemecanique magnetic motor starter switch

Maximum power AC3 duty(KW) Rated current (A) Type of enclosure Code number Suitable thermal relay
220V 230V 380V 400V 415V 440V 500V 660V 690V Long Life Normal life
2.2 4 4 4 4 4 9 IP42
IP65
LE1-D094
LE1-D093
LR2 D1312
LR2 D1314
3 5.5 5.5 5.5 5.5 5.5 12 IP45
IP55
LE1-D124
LE1-D123
LE1-D094
LE1-D093
LR2 D1316
4 7.5 9 9 10 10 18 IP42
IP55
LE1-D188
LE1-D185
LE1-D124
LE1-D123
LR2 D1321
5.5 11 11 11 15 15 25 IP42
IP55
LE1-D258
LE1-D255
LE1-D188
LE1-D185
LR2 D1322
LR2 D2353
7.5 15 15 15 18.5 18.5 32 IP55 LE1-D325 LE1-D258
LE1-D255
LR2 D2355
11 18.5 22 22 22 30 40 IP55 LE1-D405 LE1-D325 LR2 D3353
LR2 D3355
15 22 25 30 30 33 50 IP55 LE1-D505 LE1-D405 LR2 D3357
LR2 D3359
18.5 30 37 37 37 37 65 IP55 LE1-D655 LE1-D505 LR2 D3361
22 37 45 45 55 45 80 IP55 LE1-D805 LE1-D655 LR2 D3363
LR2 D3365
25 45 45 45 55 45 95 IP55 LE1-D955 LE1-D805 LR2 D3365
Categories
Magnetic Starter Or Motor Starter

Meba Electrical Motor Starter MBE1-40

Meba Electrical Motor Starter MBE1-40

Meba Electrical Motor Starter MBE1-40 is mainly applied to circuit of AC 50 or 60HZ, voltage up to 550V for far distance making and breaking circuit and frequently starting and controlling motor. It has the features of small volume, light weight, safe and reliable performance etc.

Meba Electrical Motor Starter MBE1-40

Technical Parameter:
Meba Electrical Motor Starter MBE1-40

Specifications

Product mode No.and specificatiol LE1-09 and 12 Double in sulated,protected to IP429(3) or IP659(4)
Enclosure LE1-18 and 25 Double in sulated,protected to IP427(3) or IP557(4)
LE1-32 ~ 95 Metal, IP55 to IP559
Control(2 push buttons moufited on enclosure cover) LE1-09 ~ 95 1 Green start button ’I’, ‘I’ Red stop/Teset buttion “O”
Connections LE1-09 ~ 95 Electricol power and control recircuit connections

 

LE1-D AC telemecanique magnetic motor starter switch

Standard control circuit voltages

Volts 24 42 48 110 220/230 230 240 380/400 400 415 440
50/60Hz B7 D7 E7 F7 M7 P7 U7 Q7 V7 N7 R7

 

LE1-D AC telemecanique magnetic motor starter switch

Maximum power AC3 duty(KW) Rated current (A) Type of enclosure Code number Suitable thermal relay
220V 230V 380V 400V 415V 440V 500V 660V 690V Long Life Normal life
2.2 4 4 4 4 4 9 IP42
IP65
LE1-D094
LE1-D093
LR2 D1312
LR2 D1314
3 5.5 5.5 5.5 5.5 5.5 12 IP45
IP55
LE1-D124
LE1-D123
LE1-D094
LE1-D093
LR2 D1316
4 7.5 9 9 10 10 18 IP42
IP55
LE1-D188
LE1-D185
LE1-D124
LE1-D123
LR2 D1321
5.5 11 11 11 15 15 25 IP42
IP55
LE1-D258
LE1-D255
LE1-D188
LE1-D185
LR2 D1322
LR2 D2353
7.5 15 15 15 18.5 18.5 32 IP55 LE1-D325 LE1-D258
LE1-D255
LR2 D2355
11 18.5 22 22 22 30 40 IP55 LE1-D405 LE1-D325 LR2 D3353
LR2 D3355
15 22 25 30 30 33 50 IP55 LE1-D505 LE1-D405 LR2 D3357
LR2 D3359
18.5 30 37 37 37 37 65 IP55 LE1-D655 LE1-D505 LR2 D3361
22 37 45 45 55 45 80 IP55 LE1-D805 LE1-D655 LR2 D3363
LR2 D3365
25 45 45 45 55 45 95 IP55 LE1-D955 LE1-D805 LR2 D3365
Categories
Metal Distribution Board

Meba electrical panel types plug in type surface single phase 4way MBM-4

1.Designed for safe,reliable distribution and control of electrical power as service entrance equipment in residential,commercial and light industrial installations.

2.They are available in plug in , din rail designs for indoor and outdoor applications and also available with main as MCB,isolator MCCB or MCB.

3. Impressive styling features make the enclosure a suitable addition to any high-tech equipment installation

4. For high temperature applications ,a gasket retainer may be required, please refer to factory

5. Single door, IP65 weather proof metal box ,Many sizes for your selecting

6. For use as instrument enclosures,electric hydraulic or pneumatic control housings,electrical junction boxes or terminal wiring enclosures.
Construction:

1. Body and cover are formed from 1.2mm mild steel. mounting plate in sheet  steal or galvanized steel.

2. Continuously hinged cover has steel hinges and provides 120 º opening.

Molde

Type

Phase

Ways

Main Switch

surface

Plug-in

Single

4,6,8,10,12

ELCB, Isolator ELCB+Isolator

Single Phase

H

W

D

E

F

4WAY

228

210

90

218

200

6WAY

279

210

90

269

200

8WAY

330

210

90

320

200

10WAY

381

210

90

381

200

12WAY

432

210

90

422

200

Dimension:

MBM-4 Dimension

Meba electrical panel types plug in type surface single phase  4way MBM-4 wider enclosure offers ease or wiring and move heat dissipation.

Categories
Air Conditioner Contactor

Meba Air Conditioner Contactor Switch MBK3-2P40A

Meba Air Conditioner Contactor Switch MBK3-2P40A

Meba Air Conditioner Contactor Switch MBK3-2P40A This series contactor is mainly applicable to a line of AC 50Hz or 60Hz, rated working voltage up to 600V and rated working current up to 60A, used to close or and to switch off the line. It complies to IEC947-4-1.

Meba Air Conditioner Contactor Switch MBK3-2P40A

Feature:

1.Low VA coil for cooler operation and increased life.
2.Quiet operation
3.Universal style mounting bracket fits existing mounting holes.
4. Double break contacts ensure positive make and break.
5. Screw terminals or pressure connectors and double 1/4 quick connects provided on all models for easy installation

Technical Parameter:

Coil rating 1Pole contactors 2 pole contacts
Nominal coil voltage 24 120 208/240 277 24 120 208/240 277
Nominal coil resistance Ohms 18 420 1800 2500 11 237 1000 1600
Maximum pick up voltage 18 88 177 221 18 88 177 221
Maximum drop out voltage 6-15 20-70 40-140 50-165 6-15 20-70 40-140 50-165
Nominal rush Va@50Hz 31 31 31 31 33 33 33 33
Nominal rush Va@60Hz 28 28 28 28 30 30 30 30
Nominal rush Va@50Hz 6 6 6 6 8 8 8 8
Nominal rush Va@60Hz 5 5 5 5 6.5 6.5 6.5 6.5
Maximum coil voltage 30 132 264 300 30 132 132 300