Din-Rail Mounted Energy Meters

Meba-electromechanical multi rate meter -MB041

Application

Meba electromechanical multi rate meter  MB041 is a kind of new style three phase four wire active and reactive energy meter, it adopt micro-electronics technique, and imported large scale integrate circuit, use advanced technique of digital and SMT techniques, etc. The meter completely accord with relevant technical requirements of class 1 three phase active energy meter stipulated in international standard IEC 62053-21 and class 2 three phase reactive energy meter stipulated in international standard IEC 62053-23. It can accurate and directly measure 50Hz or 60Hz active and reactive energy consumption from three phase four wire AC electricity net, it can display total energy consumption by step motor type impulse register. This meter has seven digits LCD displays shows active energy. And there are far infrared and RS485 communication module in it. Contact with all kind of AMR system conveniently. It has following features: good reliability, small volume, light weight, specious nice appearance, convenient installation, etc. This meter has already got the patent certificate from China State Intellectual Property Office at present. Patent certificate NO. ZL 2006 3 0107349.1, any other country patent certificate are in assessing.

1. 35mm standard DIN rail installation, complying with standard DIN EN50022. Or front board setting (mounting holes center distance 63 mm), users can choose any one by themselves.
2. Six pole width (Modulus 12.5mm), complying with standard JB/T7121-1993.
3. Seven digits LCD monitors, standard configuration 6+1 digits display (999999.1kWh). May select 5+2 digits display (Please specified when ordering).
4. There is a maintenance-free lithium batteries in it, use for displaying power cut reading.
5. There are a polarity port of pulse output passive closed and a no polarity port of pulse output passive distant, the output rate is 10 or 100 imp/kWh (can select), And contact with all kind of AMR system conveniently, complying with standard IEC 62053-31 and DIN 43864.
6. Three LED instructions respectively power supply state and signal of closed energy impulse and distant energy impulse.
7. Standard configuration don’t detection direction of the flow of load current. May select automatic detection the direction of the flow of load current. And instructions by an individual LED.
8. Single direction measure single phase two wire active energy consumption. It is nothing with direction of the flow of load current. Complying with standard IEC 62053-21.
9. Standard configuration type S wiring (Inlet from bottom, outlet from top) for direct connect operation, we can also choose another type of connection, and use CT (Product Configuration code is LC) and PT & CT (Product Configuration code is KC) for operation.
10. Standard configuration short terminals cover, may select extension terminals cover, in order to protect to use safety. (Product Configuration code is MF).

[Download not found]
Categories
Residual Current Circuit Breaker

Meba 2P 40A 30mA NFIN RCCB

Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: NFIN
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 2P

Application:

1. NFIN Residual Current Circuit Breaker provide the function of isolation switching and earth leakage protection of electrical circuits.

2. And also provide the indirect protection of the operator’s body against the dangerous effects of electric current and provide the protection of the fire caused by the electrical circuit fault.

Construction features

– Measuring component and buckling component of products is located between enter line end and entrance line end;
– Movement characteristic of products can not be changed with outside mechanical tool;
– The operating organization has the free function to take off and buckle;
– Operate part can not be taken down from the shell outer of products, the shell can not influence the operating organization to work, the accessory group which replace the feelers pressure, should guarantee the feelers pressure does not change while running.

Merits:

Good quality , high breaking capability, updated structure,quick trip and guide installation, competitive price,excellent and safe performance,beautiful and compact appearance, etc .

Mounting Requirements:

1. Circumstance temperature -5°C ~ +40°C, average temperature not exceeding 35°C.
2. Altitude above sea level less than 2000 m.
3. Humidity not exceeding 50% at 40°C and not exceeding 90% at 25°C.
4. Installation class II or III.
5. Pollution class 2.
6. Installation method DIN Rail mounting type.
7. The external magnetism shall not be more than 5 times of terrestrial one.
8. Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position.

PARAMETER RATING
Type Electro-magnetic, Electronic
Number of poles 2P 4P
Rated making and breaking capacity 630A
Rated Current(In) 6, 12, 25, 32, 40, 63
Rated Voltage(Un) AC 2P: 230/240V 4P: 400/415V
Rated residual operating current( In) 30 100 300 500mA
Rated residual non-operation Current( Ino) 0.5In
Residual operating current scope 0.5In~In
Residual current breaking time ≤ 0.3s
Residual current trip characteristics A, AC
Ultimate short-circuit breaking capacity (Inc) 4KA 4.5KA 6KA
Endurance ≥ 4000
Connection Capacity ≤ 25mm 2
Connection terminal torque (Max. ) 2.0Nm
Degree of protection IP20
Standard IEC/EN610018

 

[Download not found]Meba 2P 40A 30mA NFIN RCCB open a circuit automatically in the event of an earth fault between phase and earth and/or netural and earth.

Categories
Residual Current Circuit Breaker

Meba New ID RCD Residual Current Breaker MNL-4P

Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: MNL
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 4P

Application:

1. MNL 4P, Residual Current Devices for earth leakage detection.

2. It is to be used in association with miniature circuit breakers, its function is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.

3. These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.

Merits:

Good quality , high breaking capability, updated structure,quick trip and guide installation, competitive price,excellent and safe performance,beautiful and compact appearance, etc .

Mounting Requirements:

1. Circumstance temperature -5°C ~ +40°C, average temperature not exceeding 35°C.
2. Altitude above sea level less than 2000 m.
3. Humidity not exceeding 50% at 40°C and not exceeding 90% at 25°C.
4. Installation class II or III.
5. Pollution class 2.
6. Installation method DIN Rail mounting type.
7. The external magnetism shall not be more than 5 times of terrestrial one.
8. Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position.

1. Electromagnetic and Electronic type
2. 70mm wide for 2 pole Din Rail installation.
3. Standsrd: IEC1008/EN61008
4. Rated Voltage(Un): 2pole, 230V AC
5. Rated Current(In): 25, 40, 63A
6. Rated residual operating current(I△n): 30, 100, 300, 500mA
7. Rated residual non-operating current(I△no): 0.5 I△n
8. Residual current off-time: ≤0.1s
9. Minimum value of rated breaking capacity(lm): 630A
10. Rated conditional short-circuit capacity (lnc): 6KA

[Download not found]Meba New ID RCD Residual Current Breaker MNL-4P open a circuit automatically in the event of an earth fault between phase and earth and/or netural and earth.

Categories
Residual Current Circuit Breaker

Meba New ID ELCB Earth Leakage Device MNL-2P

Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: MNL
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 2P

Application:

1. MNL 2P, Residual Current Devices for earth leakage detection.

2. It is to be used in association with miniature circuit breakers, its function is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.

3. These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.

Merits:

Good quality , high breaking capability, updated structure,quick trip and guide installation, competitive price,excellent and safe performance,beautiful and compact appearance, etc .

Mounting Requirements:

1. Circumstance temperature -5°C ~ +40°C, average temperature not exceeding 35°C.
2. Altitude above sea level less than 2000 m.
3. Humidity not exceeding 50% at 40°C and not exceeding 90% at 25°C.
4. Installation class II or III.
5. Pollution class 2.
6. Installation method DIN Rail mounting type.
7. The external magnetism shall not be more than 5 times of terrestrial one.
8. Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position.

1. Electromagnetic and Electronic type
2. 35mm wide for 2 pole Din Rail installation.
3. Standsrd: IEC1008/EN61008
4. Rated Voltage(Un): 2pole, 230V AC
5. Rated Current(In): 25, 40, 63A
6. Rated residual operating current(I△n): 30, 100, 300, 500mA
7. Rated residual non-operating current(I△no): 0.5 I△n
8. Residual current off-time: ≤0.1s
9. Minimum value of rated breaking capacity(lm): 630A
10. Rated conditional short-circuit capacity (lnc): 6KA

[Download not found]Meba New ID ELCB Earth Leakage Device MNL-2P open a circuit automatically in the event of an earth fault between phase and earth and/or netural and earth.

Categories
Residual Current Circuit Breaker

Meba ID RCCB Merlin Gerin Circuit Breakers ID-4P

Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: ID
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 4P

Application:

1. ID 4P, Residual Current Devices for earth leakage detection.

2. It is to be used in association with miniature circuit breakers, its function is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.

3. These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.

Merits:

Good quality , high breaking capability, updated structure,quick trip and guide installation, competitive price,excellent and safe performance,beautiful and compact appearance, etc .

Mounting Requirements:

1. Circumstance temperature -5°C ~ +40°C, average temperature not exceeding 35°C.
2. Altitude above sea level less than 2000 m.
3. Humidity not exceeding 50% at 40°C and not exceeding 90% at 25°C.
4. Installation class II or III.
5. Pollution class 2.
6. Installation method DIN Rail mounting type.
7. The external magnetism shall not be more than 5 times of terrestrial one.
8. Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position.

1. Electromagnetic and Electronic type
2. 70mm wide for 2 pole Din Rail installation.
3. Standsrd: IEC1008/EN61008
4. Rated Voltage(Un): 2pole, 230V AC
5. Rated Current(In): 25, 40, 63A
6. Rated residual operating current(I△n): 30, 100, 300, 500mA
7. Rated residual non-operating current(I△no): 0.5 I△n
8. Residual current off-time: ≤0.1s
9. Minimum value of rated breaking capacity(lm): 630A
10. Rated conditional short-circuit capacity (lnc): 6KA

[Download not found]Meba ID RCCB Merlin Gerin Circuit Breakers ID-4P open a circuit automatically in the event of an earth fault between phase and earth and/or netural and earth.

Categories
Din-Rail Mounted Energy Meters

Meba-integrating energy meter-MB421AC

Application

Meba integrating energy meter MB421AC  is a kind of new style three phase four wire active and reactive energy meter, it adopt micro-electronics technique, and imported large scale integrate circuit, use advanced technique of digital and SMT techniques, etc. The meter completely accord with relevant technical requirements of class 1 three phase active energy meter stipulated in international standard IEC 62053-21 and class 2 three phase reactive energy meter stipulated in international standard IEC 62053-23. It can accurate and directly measure 50Hz or 60Hz active and reactive energy consumption from three phase four wire AC electricity net, it can display total energy consumption by step motor type impulse register. This meter has seven digits LCD displays shows active energy. And there are far infrared and RS485 communication module in it. Contact with all kind of AMR system conveniently. It has following features: good reliability, small volume, light weight, specious nice appearance, convenient installation, etc. This meter has already got the patent certificate from China State Intellectual Property Office at present. Patent certificate NO. ZL 2006 3 0107349.1, any other country patent certificate are in assessing. [/acc_item]
Technical Data

Model Accuracy Reference Voltage(V) Current specifications(A) Starting current(A) Insulation performance
MB421AC Active Class 1
Reactive Class 2
3X127/220
3X230/440
CT/5A 0.01 AC voltage 4kv for 1 minute,
1.2/50us waveform
impulse voltage 6kv

Installing Diagram

Dimension for MB421AC
Dimension for MB421AC

 

Wiring diagram for MB421AC
Wiring diagram for MB421AC

1.35mm standard DIN rail installation, complying with standard DIN EN50022. Or front board installed (mounting holes center distance 63 mm), users can choose any one by themselves.
2. Ten pole width (Modulus 12.5mm), complying with standard JB/T7121-1993.
3. Type S wiring (Inlet from bottom, outlet from top), use CT connect operation, may select 27 CT ratio, the meter will read directly after set, and needn’t multiplied by CT rate.
4. 7 digits LCD display, 5+2 digits(99999.91kWh, Only when CT ratio 5:5A) or 7 digits display. It is choose by the CT ratio which is set.
5. Standard configuration one port of active pulse output passive and one port of reactive pulse output passive(polarity), The output rate are 0.01, 0.1, 1, 10kWh or kvarh/Pulse. Users can choose any one by themselves. May select one port of active pulse output passive and one port of reactive pulse output passive (nonpolarity). And contact with all kind of AMR system conveniently, Complying with standard IEC 62053-31 and DIN 43864. (Please specified when ordering)
6. Standard configuration there are far infrared and a port of RS485 communication data, communication agreement complying with standard DL/T645-1997. May select without function of communication data. (Product Configuration code is NC)
7. Six LED instructions power supply state and signal of active energy impulse and reactive energy impulse and data communications state.
8. Automatic detection the direction of the flow of load current. And instructions by one LED.
9. Single direction three components measure three phase four wire active and reactive energy consumption. It is nothing with direction of the flow of load current. Complying with standard IEC 62053-21and IEC 62053-23.
10. Standard configuration short terminals cover, may select extension terminals cover, in order to protect to use safety. (Product Configuration code is AF).

[Download not found]
Categories
Residual Current Circuit Breaker

Meba ID RCCB Low Voltage Circuit Breakers ID-2P

Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: ID
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 2P

Application:

1. ID 2P, Residual Current Devices for earth leakage detection.

2. It is to be used in association with miniature circuit breakers, its function is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.

3. These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.

Merits:

Good quality , high breaking capability, updated structure,quick trip and guide installation, competitive price,excellent and safe performance,beautiful and compact appearance, etc .

Mounting Requirements:

1. Circumstance temperature -5°C ~ +40°C, average temperature not exceeding 35°C.
2. Altitude above sea level less than 2000 m.
3. Humidity not exceeding 50% at 40°C and not exceeding 90% at 25°C.
4. Installation class II or III.
5. Pollution class 2.
6. Installation method DIN Rail mounting type.
7. The external magnetism shall not be more than 5 times of terrestrial one.
8. Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position.

1. Electromagnetic and Electronic type
2. 35mm wide for 2 pole Din Rail installation.
3. Standsrd: IEC1008/EN61008
4. Rated Voltage(Un): 2pole, 230V AC
5. Rated Current(In): 25, 40, 63A
6. Rated residual operating current(I△n): 30, 100, 300, 500mA
7. Rated residual non-operating current(I△no): 0.5 I△n
8. Residual current off-time: ≤0.1s
9. Minimum value of rated breaking capacity(lm): 630A
10. Rated conditional short-circuit capacity (lnc): 6KA

[Download not found]Meba ID RCCB Low Voltage Circuit Breakers ID-2P open a circuit automatically in the event of an earth fault between phase and earth and/or netural and earth.

Categories
Residual Current Circuit Breaker

Meba 63A FIN RCCB Earth Leakage Breaker Manufacturer FIN 4Pole

Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: FIN
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 4P

Application:

1. FIN 2P, Residual Current Devices for earth leakage detection.

2. It is to be used in association with miniature circuit breakers, its function is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.

3. These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.

Merits:

Good quality , high breaking capability, updated structure,quick trip and guide installation, competitive price,excellent and safe performance,beautiful and compact appearance, etc .

Mounting Requirements:

1. Circumstance temperature -5°C ~ +40°C, average temperature not exceeding 35°C.
2. Altitude above sea level less than 2000 m.
3. Humidity not exceeding 50% at 40°C and not exceeding 90% at 25°C.
4. Installation class II or III.
5. Pollution class 2.
6. Installation method DIN Rail mounting type.
7. The external magnetism shall not be more than 5 times of terrestrial one.
8. Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position.

1. Electromagnetic and Electronic type
2. 70mm wide for 2 pole Din Rail installation.
3. Standsrd: IEC1008/EN61008
4. Rated Voltage(Un): 2pole, 230V AC
5. Rated Current(In): 25, 40, 63A
6. Rated residual operating current(I△n): 30, 100, 300, 500mA
7. Rated residual non-operating current(I△no): 0.5 I△n
8. Residual current off-time: ≤0.1s
9. Minimum value of rated breaking capacity(lm): 630A
10. Rated conditional short-circuit capacity (lnc): 6KA

[Download not found]Meba 63A FIN RCCB Earth Leakage Breaker Manufacturer FIN 4Pole open a circuit automatically in the event of an earth fault between phase and earth and/or netural and earth.

Categories
Residual Current Circuit Breaker

Meba 40A FIN RCCB Earth Leakage Breaker Manufacturer FIN 2P

Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: FIN
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 2P

Application:

1. FIN 2P, Residual Current Devices for earth leakage detection.

2. It is to be used in association with miniature circuit breakers, its function is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.

3. These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.

Merits:

Good quality , high breaking capability, updated structure,quick trip and guide installation, competitive price,excellent and safe performance,beautiful and compact appearance, etc .

Mounting Requirements:

1. Circumstance temperature -5°C ~ +40°C, average temperature not exceeding 35°C.
2. Altitude above sea level less than 2000 m.
3. Humidity not exceeding 50% at 40°C and not exceeding 90% at 25°C.
4. Installation class II or III.
5. Pollution class 2.
6. Installation method DIN Rail mounting type.
7. The external magnetism shall not be more than 5 times of terrestrial one.
8. Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position.

1. Electromagnetic and Electronic type
2. 35mm wide for 2 pole Din Rail installation.
3. Standsrd: IEC1008/EN61008
4. Rated Voltage(Un): 2pole, 230V AC
5. Rated Current(In): 25, 40, 63A
6. Rated residual operating current(I△n): 30, 100, 300, 500mA
7. Rated residual non-operating current(I△no): 0.5 I△n
8. Residual current off-time: ≤0.1s
9. Minimum value of rated breaking capacity(lm): 630A
10. Rated conditional short-circuit capacity (lnc): 6KA

[Download not found]Meba 40A FIN RCCB Earth Leakage Breaker Manufacturer FIN 2Pole open a circuit automatically in the event of an earth fault between phase and earth and/or netural and earth.

Categories
Timer relay

Meba Time Relay DH48S-2Z

Application:

DH48S time relay introduce aboard technology, supply advanced great-scale special IC and LED, according to aboard technology standard, can replace H5CN.  The product have beautiful outlook, wide time range, high precision, low power consumption, long life, big contact capacity virtues etc,are used in controlling element of auto control system.

Technical Parameter:

Voltage DC 12-48V, AC 24V-380V, 50Hz
Power Expend DC 1W, AC 1VA
Control Output 5A 220VAC
Insulation Resistance DC 500V  100MΩ
Dielectric Strenght BCC 1500VAC, BOC 1000VAC
Operating Temperature -10℃ ~ 50℃
Huminity 35%~85%
Life Mech: 107 Elec: 103
Weight ≈ 150g
Installing Holing Size 45*45mm
Time Range 0.01A~99.99S
1S~99M99S
1M~99H99M

 

Categories
Residual Current Circuit Breaker

Meba Electronic Residual Current Device OLL4-4P

Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: OLL4
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 2P

Application:

1. OLL4, Residual Current Devices for earth leakage detection.

2. It is to be used in association with miniature circuit breakers, its function is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.

3. These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.

Merits:

Good quality , high breaking capability, updated structure,quick trip and guide installation, competitive price,excellent and safe performance,beautiful and compact appearance, etc .

Mounting Requirements:

1. Circumstance temperature -5°C ~ +40°C, average temperature not exceeding 35°C.
2. Altitude above sea level less than 2000 m.
3. Humidity not exceeding 50% at 40°C and not exceeding 90% at 25°C.
4. Installation class II or III.
5. Pollution class 2.
6. Installation method DIN Rail mounting type.
7. The external magnetism shall not be more than 5 times of terrestrial one.
8. Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position.

1. Electromagnetic and Electronic type
2. 70mm wide for 2 pole Din Rail installation.
3. Standsrd: IEC1008/EN61008
4. Rated Voltage(Un): 2pole, 230V AC
5. Rated Current(In): 25, 40, 63A
6. Rated residual operating current(I△n): 30, 100, 300, 500mA
7. Rated residual non-operating current(I△no): 0.5 I△n
8. Residual current off-time: ≤0.1s
9. Minimum value of rated breaking capacity(lm): 630A
10. Rated conditional short-circuit capacity (lnc): 6KA

[Download not found]Meba  Electronic Residual Current Device OLL4-4P open a circuit automatically in the event of an earth fault between phase and earth and/or netural and earth.

Categories
Residual Current Circuit Breaker

Meba Electronic Residual Current Circuit Breaker OLL4-2P

Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: OLL4
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 2P

Application:

1. OLL4, Residual Current Devices for earth leakage detection.

2. It is to be used in association with miniature circuit breakers, its function is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.

3. These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.

Merits:

Good quality , high breaking capability, updated structure,quick trip and guide installation, competitive price,excellent and safe performance,beautiful and compact appearance, etc .

Mounting Requirements:

1. Circumstance temperature -5°C ~ +40°C, average temperature not exceeding 35°C.
2. Altitude above sea level less than 2000 m.
3. Humidity not exceeding 50% at 40°C and not exceeding 90% at 25°C.
4. Installation class II or III.
5. Pollution class 2.
6. Installation method DIN Rail mounting type.
7. The external magnetism shall not be more than 5 times of terrestrial one.
8. Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position.

1. Electromagnetic and Electronic type
2. 35mm wide for 2 pole Din Rail installation.
3. Standsrd: IEC1008/EN61008
4. Rated Voltage(Un): 2pole, 230V AC
5. Rated Current(In): 25, 40, 63A
6. Rated residual operating current(I△n): 30, 100, 300, 500mA
7. Rated residual non-operating current(I△no): 0.5 I△n
8. Residual current off-time: ≤0.1s
9. Minimum value of rated breaking capacity(lm): 630A
10. Rated conditional short-circuit capacity (lnc): 6KA

[Download not found]Meba Electronic Residual Current Circuit Breaker OLL4-2P open a circuit automatically in the event of an earth fault between phase and earth and/or netural and earth.

Categories
Residual Current Circuit Breaker

MEBA Electromagnetic Residual Current Device PFIM40-4P

Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: PFIM
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 2P

Application:

1. PFIM 2P, Residual Current Devices for earth leakage detection.

2. It is to be used in association with miniature circuit breakers, its function is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.

3. These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.

Merits:

Good quality , high breaking capability, updated structure,quick trip and guide installation, competitive price,excellent and safe performance,beautiful and compact appearance, etc .

Mounting Requirements:

1. Circumstance temperature -5°C ~ +40°C, average temperature not exceeding 35°C.
2. Altitude above sea level less than 2000 m.
3. Humidity not exceeding 50% at 40°C and not exceeding 90% at 25°C.
4. Installation class II or III.
5. Pollution class 2.
6. Installation method DIN Rail mounting type.
7. The external magnetism shall not be more than 5 times of terrestrial one.
8. Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position.

1. Electromagnetic and Electronic type
2. 70mm wide for 2 pole Din Rail installation.
3. Standsrd: IEC1008/EN61008
4. Rated Voltage(Un): 2pole, 230V AC
5. Rated Current(In): 25, 40, 63A
6. Rated residual operating current(I△n): 30, 100, 300, 500mA
7. Rated residual non-operating current(I△no): 0.5 I△n
8. Residual current off-time: ≤0.1s
9. Minimum value of rated breaking capacity(lm): 630A
10. Rated conditional short-circuit capacity (lnc): 6KA

[Download not found]MEBA Electromagnetic Residual Current Device PFIM40-4P open a circuit automatically in the event of an earth fault between phase and earth and/or netural and earth.

Categories
Timer relay

Meba Time Delay Relay ST-3P

Application:

1. Time Delay Relay ST3PF series time relay is used ASIC and professional manufacturing technology to produce innovative time relay, with small size, light weight, delay a wide range of anti-interference ability, long life characteristics.

2. To be suitable for a variety of demanding precision, high reliability, automation and control sites used for delay control.

Normal operating conditions and installation conditions:

1. Use of the environment: the altitude not exceeding 2,000 m; around the attack is not higher than +40 ambient temperature and not lower than -5 ;

2. Supply voltage range of 85% -110% rated voltage; in the absence of severe shock and explosion medium risk and medium non-corrosive metal and undermine the insulation is sufficient gas and dust; in the absence of rain and snow in places;

3. Vertical or horizontal installation;

 

Classification Multirange Timer
Model ST3P
Dimension 55H*40.5W*57.5D
Mounting & Socket Surface(-N) PF-083A(E)
Flush(-Y) US-08 P3G-08
Full Timing Range -A: 0.05~0.5s/5s/30s/3min-B:0.1~1s/10s/60s/6min-C:0.5~5s/50s/5min/30min-D:1~10s/100s/10min/60min

-E:5~60s/10min/60min/6h

-F:0.25~2min/20min/2h/12h

-G:0.5~4min/40min/4h/24h

Rated Voltage 24V to 240 VAC/DCAC(V)110V, 220VDC(V)12V, 24V
Indicator Operating ON, UP, Operating
O/P Contact Model ST3PA ST3PC
Time Limit 1C 5A
Time Limit 2C 5A
Instantenous 1C 5A
Life Mechanical 5*107 times
Electrical 105 times
Accuracy Repea Terror ±2%max
Stting Error ±5%max
Voltage Error ±5%max
Temp Error ±2%max
Categories
Din-Rail Mounted Energy Meters

Meba-reading electric meter-MB421GC

Application

Meba reading electric meter MB421GC is a kind of new style three phase four wire active energy meter, it adopt micro-electronics technique, and imported large scale integrate circuit, use advanced technique of digital and SMT techniques, etc. The meter completely accord with relevant technical requirements of class 1 three phase active energy meter stipulated in international standard IEC 62053-21 and class 2 three phase reactive energy meter stipulated in international standard IEC 62053-23. It can accurate and directly measure 50Hz or 60Hz active and reactive energy consumption from three phase four wire AC electricity net, it can display total energy consumption by step motor type impulse register. This meter has seven digits LCD displays shows active energy. And there are far infrared and RS485 communication module in it. Contact with all kind of AMR system conveniently. It has following features: good reliability, small volume, light weight, specious nice appearance, convenient installation, etc. This meter has already got the patent certificate from China State Intellectual Property Office at present. Patent certificate NO. ZL 2006 3 0107349.1, any other country patent certificate are in assessing.

Technical Data

Model Accuracy Reference Voltage(V) Current specifications(A) Starting current(A) Insulation performance
MB421GC Active Class 1
Reactive Class 2
3X127/220
3X230/440
5(30)
10(60)
20(100)
0.02
0.04
0.08
AC voltage 4kv for 1 minute,
1.2/50us waveform
impulse voltage 6kv

Installing Diagram

Dimension for MB421GC
Dimension for MB421GC

 

Wiring diagram for MB421GC
Wiring diagram for MB421GC

1. 35mm standard DIN rail installation, complying with standard DIN EN50022. Or front board installed (mounting holes center distance 63 mm), users can choose any one by themselves.
2. Ten pole width (Modulus 12.5mm), complying with standard JB/T7121-1993.
3. May select 6+1 digits display (999999.1kWh, default) or 6+1 digits display, users can choose any one by themselves form far infrared or port of RS485 communication.
4. Standard configuration one port of active pulse output passive and one port of reactive pulse output passive(polarity). The output rate are 0.01, 0.1, 1, 10kWh or kvarh/Pulse. Users can choose any one by themselves. May select one port of active pulse output passive and one port of reactive pulse output passive (nonpolarity). And contact with all kind of AMR system conveniently, Complying with standard IEC 62053-31 and DIN 43864. (Please specified when ordering)
5. There are far infrared and a port of RS485 communication data, communication agreement complying with standard DL/T645-1997. May select any other communication agreement.
6. Six LED instructions every power supply state and signal of active energy impulse and reactive energy impulse and data communications state.
7. Automatic detection the direction of the flow of load current. And instructions by one LED.
8. Single direction three components measure three phase four wire active and reactive energy consumption. It is nothing with direction of the flow of load current. Complying with standard IEC 62053-21and IEC 62053-23.
9. Standard configuration type S wiring (Inlet from top, outlet from bottom), directly connect operation, may select use CT (Product Configuration code is FC) and PT&CT (Product Configuration code is EC) for operation.
10. Standard configuration short terminals cover, may select extension terminals cover, in order to protect to use safety. (Product Configuration code is GF). 

[Download not found]
Categories
Timer relay

Meba Timer Switches TB-35

Application:

1.  TB-35  Mechanical Timer is suit for water heater, Water dispenser, Street lamp, Staircase lamp,Breed aquatics, Irrigation, office power auto control, anywhere need time control in civilian, home or industrial, etc.

2.  It can set 8 programs to control ON or OFF of electric appliance in 24 hours or set 48 programs in one week. It can be programmed to avoid the peak of power, and distribute power in time limit to save energy.

3.  This timer is a kind of module for DIN guide rail, easy to installation in illumination box, and its so compact size with pretty form.

4.  Its time base component is adopt synch pulse motor and it is strong anti-jamming, small consume with performance stability.

Technical Parameter:

Classification Timer Timer Timer Timer
Specification/Model TB-35 TB-38B SUL181h E8
Contact Capacity AC220V 10A AC220V 10A AC220V 16A AC220V 10A
Full Timing Range 24h 24h 24h 7m
Contact Resistance ≥50mΩ ≥50mΩ ≥50mΩ ≥50mΩ
Insulation Resistance ≤100MΩ ≤100MΩ ≤100MΩ ≤100MΩ
Coil Voltage 100~240V AC 100~240V AC 110,230V AC 110,230V AC
Life Electrical 105 Times 105 Times 105 Times 105 Times
Mechanical 107 Times 107 Times 107 Times 107 Times
Operating Temperature -40oC~+55oC -40oC~+55oC -40oC~+55oC -40oC~+55oC
Storage Battery (Working Reserve) Without Battery Time 150h Time 150h
Minimum Setting Unit 15Minutes 15Minutes 30Minutes 0.5Minutes
Set Up Times 15 m/per times 96 times 15 m/per times 96 times 30 m/per times 48 times 1M,1.5M,2M,2.5M, 3M,3.5M,4.5M,5M, 5.5M,6M,6.5M,7M
Categories
Residual Current Circuit Breaker

Meba Earth Leakage Current Circuit Breaker PFIM-2P

Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: PFIM
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 2P

Application:

1. PFIM 2P, Residual Current Devices for earth leakage detection.

2. It is to be used in association with miniature circuit breakers, its function is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.

3. These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.

Merits:

Good quality , high breaking capability, updated structure,quick trip and guide installation, competitive price,excellent and safe performance,beautiful and compact appearance, etc .

Mounting Requirements:

1. Circumstance temperature -5°C ~ +40°C, average temperature not exceeding 35°C.
2. Altitude above sea level less than 2000 m.
3. Humidity not exceeding 50% at 40°C and not exceeding 90% at 25°C.
4. Installation class II or III.
5. Pollution class 2.
6. Installation method DIN Rail mounting type.
7. The external magnetism shall not be more than 5 times of terrestrial one.
8. Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position.

1. Electromagnetic and Electronic type
2. 35mm wide for 2 pole Din Rail installation.
3. Standsrd: IEC1008/EN61008
4. Rated Voltage(Un): 2pole, 230V AC
5. Rated Current(In): 25, 40, 63A
6. Rated residual operating current(I△n): 30, 100, 300, 500mA
7. Rated residual non-operating current(I△no): 0.5 I△n
8. Residual current off-time: ≤0.1s
9. Minimum value of rated breaking capacity(lm): 630A
10. Rated conditional short-circuit capacity (lnc): 6KA

[Download not found] Meba Earth Leakage Current Circuit Breaker PFIM-2P open a circuit automatically in the event of an earth fault between phase and earth and/or netural and earth.

Categories
Residual Current Circuit Breaker

Meba Rccb And Rcbo PFIM40-2P

Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: PFIM
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 2P

Application:

1. PFIM 2P, Residual Current Devices for earth leakage detection.

2. It is to be used in association with miniature circuit breakers, its function is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application.

3. These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.

Merits:

Good quality , high breaking capability, updated structure,quick trip and guide installation, competitive price,excellent and safe performance,beautiful and compact appearance, etc .

1. Electromagnetic and Electronic type
2. 35mm wide for 2 pole Din Rail installation.
3. Standsrd: IEC1008/EN61008
4. Rated Voltage(Un): 2pole, 230V AC
5. Rated Current(In): 25, 40, 63A
6. Rated residual operating current(I△n): 30, 100, 300, 500mA
7. Rated residual non-operating current(I△no): 0.5 I△n
8. Residual current off-time: ≤0.1s
9. Minimum value of rated breaking capacity(lm): 630A
10. Rated conditional short-circuit capacity (lnc): 6KA

Mounting Requirements:

1. Circumstance temperature -5°C ~ +40°C, average temperature not exceeding 35°C.
2. Altitude above sea level less than 2000 m.
3. Humidity not exceeding 50% at 40°C and not exceeding 90% at 25°C.
4. Installation class II or III.
5. Pollution class 2.
6. Installation method DIN Rail mounting type.
7. The external magnetism shall not be more than 5 times of terrestrial one.
8. Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position.

[Download not found]Meba Rccb And Rcbo PFIM40-2P open a circuit automatically in the event of an earth fault between phase and earth and/or netural and earth.

Categories
Timer relay

Meba 24 hours Electric Timer Switch TB-35B

Application:

1.  TB-35B Mechanical Timer is suit for water heater, Water dispenser, Street lamp, Staircase lamp,Breed aquatics, Irrigation, office power auto control, anywhere need time control in civilian, home or industrial, etc.

2.  It can set 8 programs to control ON or OFF of electric appliance in 24 hours or set 48 programs in one week. It can be programmed to avoid the peak of power, and distribute power in time limit to save energy.

3.  This timer is a kind of module for DIN guide rail, easy to installation in illumination box, and its so compact size with pretty form.

4.  Its time base component is adopt synch pulse motor and it is strong anti-jamming, small consume with performance stability.

Technical Parameter:

Classification Timer Timer Timer Timer
Specification/Model TB-35 TB-38B SUL181h E8
Contact Capacity AC220V 10A AC220V 10A AC220V 16A AC220V 10A
Full Timing Range 24h 24h 24h 7m
Contact Resistance ≥50mΩ ≥50mΩ ≥50mΩ ≥50mΩ
Insulation Resistance ≤100MΩ ≤100MΩ ≤100MΩ ≤100MΩ
Coil Voltage 100~240V AC 100~240V AC 110,230V AC 110,230V AC
Life Electrical 105 Times 105 Times 105 Times 105 Times
Mechanical 107 Times 107 Times 107 Times 107 Times
Operating Temperature -40oC~+55oC -40oC~+55oC -40oC~+55oC -40oC~+55oC
Storage Battery (Working Reserve) Without Battery Time 150h Time 150h
Minimum Setting Unit 15Minutes 15Minutes 30Minutes 0.5Minutes
Set Up Times 15 m/per times 96 times 15 m/per times 96 times 30 m/per times 48 times 1M,1.5M,2M,2.5M, 3M,3.5M,4.5M,5M, 5.5M,6M,6.5M,7M
Categories
Timer relay

Meba 24 hours timer switch SUL181H

1. SUL 181h Mechanical Timer Switch is suit for water heater, Water dispenser, Street lamp, Staircase lamp, Advertisinglamp box,Breed aquatics, Irrigation, office power auto control, anywhere need time control in civilian, home or industrial, etc.

2. It can set 8 programs to control ON or OFF of electric appliance in 24 hours or set 48 programs in one week. It can be programmed to avoid the peak of power, and distribute power in time limit to save energy.

3. This timer is a kind of module for DIN guide rail, easy to installation in illumination box, and its so compact size with pretty form.. Its time base component is adopt synch pulse motor and it is strong anti-jamming, small consume with performance stability.

Classification Timer
Model SUL181h
Contact Capacity AC 220V 16A
Full Timing Ranfe 24h
Contact Resistance ≤50mΩ
Insulation Resistance ≥100mΩ
Coil Voltage 110,230V AC
Life Electrical 105 times
Mechanical 107 times
Operating Temperature -40+55℃
Minimun setting unit 30 minutes
Set up times 30m/per times 48times
STO Nage Battery Time 150h