Meba Single phase AC Solid State Relay SSR-25DA

Application
1. Solid State Relay is called “SSR” for short. This products made by our factory is the latest non-contact electronic switch device with good ON-OFF performance.

2. Its input end only requires tinny control current and can be compatible with integrated circuit of TT land CMOS, etc. The output return circuit adopts two way controlled silicon or big powder transistors to cut on or cut off the loading current.

3. The photoelectric coupler is adopted between the input and output.
Features and Uses
1. Because solid state relay is a non-contact switch element made up of solid state elements. Compared with electromagnetic relay, it is more reliable. It has series advantages, such as long service life, little disturbance to surrounding and strong anti-interference performance,etc.

2. It has wide application fields, like input/output interface of computer and program control, electric stove heating constant temperature equipment, digital control machine, remote control system, industrial automatic device, signal lamp, traffic lamp, stage lighting control equipment, instrument and meter, medical equipment , duplicator, color enlarger, and rubber & plastic machine,etc.

3. In some special devices which require damp proof, fireproof and anti-corrosion , and under bad working environment , SSR has incomparable superiority in comparison with tradition electromagnetic relay.

Load Current

10A,15A,25A,30A,40A

Load Voltage

24-380VAC

Control Voltage

3~32VDC

Control Current

3-25mA

On Voltage

≤1.5VAC

Off Leakage Current

≤4mA

On-off Time

≤10mS

Dielectric Strength

2500VAC

Insulation Resistance

100MΩ/500VDC

Ambient Temperature

-20~+75°C

Mounting Methods

Screw Fixed

The work Instructions

LED

Weight

132g

Categories
Din-Rail Mounted Energy Meters

Meba-LCD digital portable meter-MB011JC

Application

Meba-LCD digital portable meter-MB011JC  is a kind of new style single phase two wire active energy meter, it adopt micro-electronics technique, and imported large scale integrate circuit, use advanced technique of digital and SMT techniques, etc. The meter completely accord with relevant technical requirements of class 1 single phase active energy meter stipulated in international standard IEC 62053-21. It can accurate and directly measure 50Hz or 60Hz active energy consumption from single phase AC electricity net. This meter has seven digits LCD displays shows the active energy consumption. It has following features: good reliability, small volume, light weight, specious nice appearance, convenient installation, etc. This meter has already got the patent certificate from China State Intellectual Property Office at present. Patent certificate NO. ZL 2006 3 0106828.1, any other country patent certificate are in assessing.
Technical Data

Model Accuracy Reference voltage (V) Current specifications (A) Starting current (A) Insulation performance
MB011JC Class 1 127
230
5(30)
10(50)
20(100)
0.02
0.04
0.08
AC voltage 4kV for 1 minute,
1.2/50us waveform
impulse voltage 6kV

Installing Diagram

 

Dimension for MB011JC LCD
 Dimension for MB011JC LCD

 

 

 

Wiring diagram for MB011JC
Wiring diagram for MB011JC 

– 35mm standard DIN rail installation, complying with standard DIN EN50022. Or front board setting (mounting holes center distance 63 mm), users can choose any one by themselves.
– Six pole width (Modulus 12.5mm), complying with standard JB/T7121-1993.
– Standard configuration 6+1 digits display (999999.1kWh). May select 5+2 digits display (Please specified when ordering).
– Standard configuration Impulse output passive (polarity), May select distant impulse output passive (no polarity). And contact with all kind of AMR system conveniently, complying with standard IEC 62053-31 and DIN 43864.
– Two LED instructions respectively power supply state (green) and signal of energy impulse (red).
– Standard configuration don’t detection direction of the flow of load current. May select automatic detection the direction of the flow of load current. And instructions by an individual LED.
– Single direction measure single phase two wire active energy consumption. It is nothing with direction of the flow of load current. Complying with standard IEC 62053-21.
– Standard configuration type S wiring (Inlet from bottom, outlet from top) for direct connect operation, we can also choose another type of connection, and use CT (Product Configuration code is IC) and PT & CT (Product Configuration code is HC) for operation.
– Standard configuration short terminals cover, may select extension terminals cover, in order to protect to use safety. (Product Configuration code is JF).

[Download not found]
Categories
Relay

Meba DC/AC Single Phase Solid State Relay ZG3NC-340B

Application
1. Solid State Relay is called “SSR” for short. This products made by our factory is the latest non-contact electronic switch device with good ON-OFF performance.

2. Its input end only requires tinny control current and can be compatible with integrated circuit of TT land CMOS, etc. The output return circuit adopts two way controlled silicon or big powder transistors to cut on or cut off the loading current.

3. The photoelectric coupler is adopted between the input and output.
Features and Uses
1. Because solid state relay is a non-contact switch element made up of solid state elements. Compared with electromagnetic relay, it is more reliable. It has series advantages, such as long service life, little disturbance to surrounding and strong anti-interference performance,etc.

2. It has wide application fields, like input/output interface of computer and program control, electric stove heating constant temperature equipment, digital control machine, remote control system, industrial automatic device, signal lamp, traffic lamp, stage lighting control equipment, instrument and meter, medical equipment , duplicator, color enlarger, and rubber & plastic machine,etc.

3. In some special devices which require damp proof, fireproof and anti-corrosion , and under bad working environment , SSR has incomparable superiority in comparison with tradition electromagnetic relay.

Load Current

10A,15A,25A,30A,40A,50A,60A,75A,80A,90A,100A,120A

Load Voltage

240VAC

Control Voltage

3~32VDC

Control Current

3-25mA

On Voltage

≤1.5VAC

Off Leakage Current

≤4mA

On-off Time

≤10mS

Dielectric Strength

2500VAC

Insulation Resistance

100MΩ/500VDC

Ambient Temperature

-20~+75°C

Mounting Methods

Screw Fixed

The work Instructions

LED

Weight

135g

Categories
Relay

Meba Solid State Relay

Application
1. Solid State Relay is called “SSR” for short. This products made by our factory is the latest non-contact electronic switch device with good ON-OFF performance.

2. Its input end only requires tinny control current and can be compatible with integrated circuit of TT land CMOS, etc. The output return circuit adopts two way controlled silicon or big powder transistors to cut on or cut off the loading current.

3. The photoelectric coupler is adopted between the input and output.
Features and Uses
1. Because solid state relay is a non-contact switch element made up of solid state elements. Compared with electromagnetic relay, it is more reliable. It has series advantages, such as long service life, little disturbance to surrounding and strong anti-interference performance,etc.

2. It has wide application fields, like input/output interface of computer and program control, electric stove heating constant temperature equipment, digital control machine, remote control system, industrial automatic device, signal lamp, traffic lamp, stage lighting control equipment, instrument and meter, medical equipment , duplicator, color enlarger, and rubber & plastic machine,etc.

3. In some special devices which require damp proof, fireproof and anti-corrosion , and under bad working environment , SSR has incomparable superiority in comparison with tradition electromagnetic relay.

 

Load Current

10A,15A,25A,30A,40A

Load Voltage

24-380VAC

Control Voltage

3~32VDC

Control Current

3-25mA

On Voltage

≤1.5VAC

Off Leakage Current

≤4mA

On-off Time

≤10mS

Dielectric Strength

2500VAC

Insulation Resistance

100MΩ/500VDC

Ambient Temperature

-20~+75°C

Mounting Methods

Screw Fixed

The work Instructions

LED

Weight

132g

Categories
Din-Rail Mounted Energy Meters

Meba-energing active metering-MB011MC

Application

Meba-energing active metering-MB011MC is a kind of new style single phase two wire active energy meter, it adopt micro-electronics technique, and imported large scale integrate circuit, use advanced technique of digital and SMT techniques, etc. The meter completely accord with relevant technical requirements of class 1 single phase active energy meter stipulated in international standard IEC 62053-21. It can accurate and directly measure 50Hz or 60Hz active energy consumption from single phase AC electricity net. This meter has seven digits LCD displays shows the active energy consumption. It has following features: good reliability, small volume, light weight, and there are far infrared and RS485 communication module in it. Contact with all kind of AMR system conveniently. It has following features: Good reliability, small volume, light weight, specious nice appearance, convenient installation, etc. This meter has already got the patent certificate from China State Intellectual Property Office at present. Patent certificate NO. ZL 2006 3 0106828.1, any other country patent certificate are in assessing.[/acc_item]
Technical Data

Model Accuracy Reference Voltage(V) Current specifications(A) Starting current(A) Insulation performance
MB011MC Class 1 127
230
5(30)
10(50)
20(100)
0.02
0.04
0.08
AC voltage 4kv for 1 minute,
1.2/50us waveform
pulse voltage 6kv

Installing Diagram

Dimensions

Dimension for MB011MC
Dimension for MB011MC

Wiring Diagram

Wiring Diagram for MB011MC
Wiring Diagram for MB011MC

1. 35mm standard DIN rail installation, complying with standard DIN EN50022. Or front board setting (mounting holes center distance 63 mm), users can choose any one by themselves.
2. Six pole width (Modulus 12.5mm), complying with standard JB/T7121-1993.
3. Seven digits LCD monitors, standard configuration 6+1 digits display (999999.1kWh). May select 5+2 digits display (Please specified when ordering).
4. There is a maintenance-free lithium batteries in it, use for displaying power cut reading.
5. There are a polarity port of pulse output passive closed and a no polarity port of pulse output passive distant, the output rate is 10 or 100 imp/kWh (can select), And contact with all kind of AMR system conveniently, complying with standard IEC 62053-31 and DIN 43864.
6. Three LED instructions respectively power supply state and signal of closed energy impulse and distant energy impulse.
7. Standard configuration don’t detection direction of the flow of load current. May select automatic detection the direction of the flow of load current. And instructions by an individual LED.
8. Single direction measure single phase two wire active energy consumption. It is nothing with direction of the flow of load current. Complying with standard IEC 62053-21.
9. Standard configuration type S wiring (Inlet from bottom, outlet from top) for direct connect operation, we can also choose another type of connection, and use CT (Product Configuration code is LC) and PT & CT (Product Configuration code is KC) for operation.
10. Standard configuration short terminals cover, may select extension terminals cover, in order to protect to use safety. (Product Configuration code is MF).

[Download not found]
Categories
Relay

Meba Three Phase AC Solid State Relay ZG33-3100B

Application
1. Solid State Relay is called “SSR” for short. This products made by our factory is the latest non-contact electronic switch device with good ON-OFF performance.

2. Its input end only requires tinny control current and can be compatible with integrated circuit of TT land CMOS, etc. The output return circuit adopts two way controlled silicon or big powder transistors to cut on or cut off the loading current.

3. The photoelectric coupler is adopted between the input and output.
Features and Uses
1. Because solid state relay is a non-contact switch element made up of solid state elements. Compared with electromagnetic relay, it is more reliable. It has series advantages, such as long service life, little disturbance to surrounding and strong anti-interference performance,etc.

2. It has wide application fields, like input/output interface of computer and program control, electric stove heating constant temperature equipment, digital control machine, remote control system, industrial automatic device, signal lamp, traffic lamp, stage lighting control equipment, instrument and meter, medical equipment , duplicator, color enlarger, and rubber & plastic machine,etc.

3. In some special devices which require damp proof, fireproof and anti-corrosion , and under bad working environment , SSR has incomparable superiority in comparison with tradition electromagnetic relay.

Load Current

10A,15A,25A,30A,40A,50A,60A,75A,80A,100A,120A

Load Voltage

480VAC

Control Voltage

3~32VDC

Control Current

10-68mA

On Voltage

≤1.8VAC

Off Leakage Current

≤10mA

On-off Time

≤10mS

Dielectric Strength

2500VAC

Insulation Resistance

100MΩ/500VDC

Ambient Temperature

-20~+75°C

Mounting Methods

Screw Fixed

The work Instructions

LED

Weight

450g

Categories
Din-Rail Mounted Energy Meters

Meba smart energy meter MB011ZA

Application

Meba-smart energy meter-MB011ZA is a kind of new style single phase two wire active energy meter, it is fit for use on rental houses, and with two power energy counters, use for recording total energy and daily energy. The meter completely accord with relevant technical requirements of class 1 single phase active energy meter stipulated in international standard IEC 62053-21. It can accurately and directly measure 50Hz or 60Hz active energy consumption from single phase AC electricity net, it can display total energy consumption by step type impulse register. This meter has LCD display active energy, it has following features: good reliability, small volume, light weight, specious nice appearance, convenient installation, etc. This meter has already got the patent certificate from China State Intellectual Property Office at present. Patent certificate NO. ZL 2006 3 0106726.X, any other country patent certificate are in assessing.[/acc_item]
Technical Data

Model Accuracy Reference Voltage(V) Current specifications(A) Starting current(A) Insulation performance
MB011ZA Class 1 127
230
5(30)
10(50)
20(100)
0.02
0.04
0.08
AC voltage 4kv for 1 minute,
1.2/50us waveform
impulse voltage 6kv

Installing Diagram

Dimensions

Dimension for MB011ZA
Dimension for MB011ZA

 

Wiring Diagram

Wiring diagram for MB011ZA
Wiring diagram for MB011ZA

1. 35mm standard DIN rail installation, complying with standard DIN EN50022. Or front board setting (mounting holes center distance 63 mm), users can choose any one by themselves.
2. Six pole width (Modulus 12.5mm), complying with standard JB/T7121-1993.
3. Two 6 digits LCD display, use for display total energy (5+1 digits display) and daily energy (4+2 digits display), and we can cleared the number form the red button on the panel, the red button can be protected by lead closed.
4. Standard configuration LCD display without backlighting, may select with white backlighting, and there is maintenance-free battery, use for display when the power cut off. (Product Configuration code is ZC)
5. Standard configuration one port of pulse output passive (polarity), May select increase a distant port of pulse output passive ( no polarity). And contact with all kind of AMR system conveniently, complying with standard IEC 62053-31 and DIN 43864.
6. Two LED instructions power supply state (green) and signal of energy impulse (red).
7. Standard configuration don’t detection direction of the flow of load current. May select automatic detection the direction of the flow of load current. And instructions (Only green LED energy pulse signal when working, that is meaning the direction of the flow of load current reverse).
8. Single direction measure single phase two wire active Power consumption. It is nothing with direction of the flow of load current. Complying with standard IEC 62053-21.
9. Directly connect operation, there are two types you may select. Standard configuration type S wiring, may select type T wiring (Product Configuration code is TA).
10. Standard configuration short terminals cover, may select extension terminals cover, in order to protect to use safety. (Product Configuration code is ZB).

[Download not found]
Categories
Trunking

Wiring duct electrical accessories

Material: Environmental protection and rigid PVC with good insulation performance and non-combustion. It is environmental protection and pollution-free which is approval by ROHS certificate, and without harmful substances like lead.
Fire-resistance class: UL94V-0 approval, flame-retardant material withgood self-extinguishing and insulation.
Product structure: consist of wiring duct and its cover.
Color&Size: grey, white, blue(Other colors can be customized);
Working temperature: temperature-resistance -20 to +85 ℃

Wiring duct electrical accessories

Features:
1. more than 100 models and sizes, and each equipped with cover.
2. the buckle of the duct and cover is reverse-buckle type, never slided off, with smooth surface, conveniently and qucikly to install, and effectively to prevent slide caused by vibrations.
3. smooth slot, glitch-free, and will not cut hands and abrase the wires.
4. low thread hole, easy combination, knocking down and wiring.
5. the wiring duct will not break, distort, change colors under the temperature of +85

Item.No. HW Contained Wire (1.52) Length
PXC-2015 2015 5-10PCS 2M
PXC-2020 2020 10-15PCS
PXC-2025 2025 10-20PCS
PXC-2525 2525 10-25PCS
PXC-2545 2545 25-40PCS
PXC-3015 3015 5-15PCS
PXC-3020 3020 10-20PCS
PXC-3025 3025 15-25PCS
PXC-3030 3030 20-30PCS
PXC-3035 3035 30-45PCS
PXC-3040 3040 35-50PCS
PXC-3050 3050 45-60PCS
PXC-3525 3525 25-35PCS
PXC-3535 3535 40-55PCS
PXC-4025 4025 20-40PCS
PXC-4030 4030 35-50PCS
PXC-4035 4035 40-50PCS
PXC-4040 4040 45-55PCS
PXC-4060 4060 60-80PCS
PXC-4525 4525 25-40PCS
PXC-4535 4535 40-55PCS
PXC-4545 4535 60-70PCS
PXC-4565 4565 90-100PCS
PXC-5015 5015 25-35PCS
PXC-5025 5025 25-45PCS
PXC-5030 5030 30-55PCS
PXC-5035 5035 50-60PCS
PXC-5040 5040 60-70PCS
PXC-5045 5045 70-85PCS
PXC-5050 5050 90-100PCS
PXC-5055 5055 100-110PCS
PXC-5060 5060 95-105PCS
PXC-5080 5080 180-200PCS
PXC-50100 5080 220-250PCS
PXC-6040 6040 90-100PCS
PXC-6060 6060 140-160PCS
PXC-6525 6525 100-110PCS
PXC-6545 6545 180-200PCS
PXC-6565 6565 140-160PCS
PXC-8035 8035 160-180PCS
PXC-8045 8045 180-200PCS
PXC-8050 8050 200-220PCS
PXC-8055 8055 240-290PCS
PXC-8080 8080 280-350PCS
PXC-80100 80100 300-400PCS
PXC-100100 100100 300-400PCS

Remark: Standard length is 2 meters, customized length is acceptable. Standard color is white and grey, other colors can be customized.

Dimensions:

Categories
Trunking

Plastic trunking electrical accessories

Material: Environmental protection and rigid PVC with good insulation performance and non-combustion. It is environmental protection and pollution-free which is approval by ROHS certificate, and without harmful substances like lead.
Fire-resistance class: UL94V-0 approval, flame-retardant material withgood self-extinguishing and insulation.
Product structure: consist of wiring duct and its cover.
Color&Size: grey, white, blue(Other colors can be customized);
Working temperature: temperature-resistance -20 to +85 ℃

Plastic trunking electrical accessories

Features:
1. more than 100 models and sizes, and each equipped with cover.
2. the buckle of the duct and cover is reverse-buckle type, never slided off, with smooth surface, conveniently and qucikly to install, and effectively to prevent slide caused by vibrations.
3. smooth slot, glitch-free, and will not cut hands and abrase the wires.
4. low thread hole, easy combination, knocking down and wiring.
5. the wiring duct will not break, distort, change colors under the temperature of +85

 

Item Specification Thickness(MM) Lengths(m) Packing Quantity(pcs)
PVC Trunking 10×10 0.60 2m-4m 50
PVC Trunking 15×10 0.55 2m-4m 50
PVC Trunking 16×16 0.58 / 0.63 / 1.00 2m-4m 50
PVC Trunking 20×10 0.55 / 0.65 2m-4m 50
PVC Trunking 24×14 0.65 / 0.80 2m-4m 25
PVC Trunking 25×16 0.63 / 0.72 / 1.00 2m-4m 25
PVC Trunking 25×25 0.80 2m-4m 16
PVC Trunking 30×15 0.60 / 0.76 2m-4m 16
PVC Trunking 39×19 0.75 / 0.90 2m-4m 10
PVC Trunking 40×16 0.60 / 0.80 2m-4m 10
PVC Trunking 40×25 0.68 / 0.76 / 1.00 2m-4m 10
PVC Trunking 40×40 1.38 2m-4m 6
PVC Trunking 50×25 1.00 2m-4m 6
PVC Trunking 50×50 1.25 2m-4m 4
PVC Trunking 59×22 0.85 / 1.10 2m-4m 4
PVC Trunking 60×40 1.40 2m-4m 2
PVC Trunking 60×60 1.68 2m-4m 2
PVC Trunking 75×50 1.25 2m-4m 2
PVC Trunking 75×75 1.30 / 1.50 2m-4m 2
PVC Trunking 80×40 1.35 2m-4m 3
PVC Trunking 80×50 1.40 2m-4m 2
PVC Trunking 99×27 0.90 / 1.20 2m-4m 2
PVC Trunking 100×40 1.35 / 1.50 2m-4m 2
PVC Trunking 100×50 1.35 / 1.70 2m-4m 2
PVC Trunking 100×60 1.65 2m-4m 2
PVC Trunking 100×75 1.65 2m-4m 2
PVC Trunking 100×100 1.60 / 2.00 2m-4m 1
Categories
Residual Current Circuit Breaker

Meba Earth Leakage Current device MBR2

Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: MBACH2
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 2P

Application:

1. MBR2 RCCB provide the function of isolat ion switching and earth leakage protection of electrical circuits .

2. They open a circuit automatically in the event of an earth fault between phase and earth and/or neutral and earth.

3. A wide range of current ratings and sen sitivities are available. Suitable for domestic, commercial and industrial applications.

 

Merits:

Good quality , high breaking capability, updated structure,quick trip and guide installation, competitive price,excellent and safe performance,beautiful and compact appearance, etc .

Mounting Requirements:

1. Circumstance temperature -5°C ~ +40°C, average temperature not exceeding 35°C.
2. Altitude above sea level less than 2000 m.
3. Humidity not exceeding 50% at 40°C and not exceeding 90% at 25°C.
4. Installation class II or III.
5. Pollution class 2.
6. Installation method DIN Rail mounting type.
7. The external magnetism shall not be more than 5 times of terrestrial one.
8. Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position.

Rated Voltage

1Pole+N: 230/240V AC, 3Pole+N: 400/415V AC

 Rated Current

10, 16, 20, 25, 32, 40A

 Rated Frequency

 50/60Hz

 Rated Residual Operating Current

 30, 100, 300, 500mA

Rated residual non-operating current(I no)

 0.5ls n

 Rated Circuit Breaking Capacity

 4.5KA

Residual current off-time

0.1S

Operating temperatur2

-5 to +55℃

Standard

IEC61008-1

[Download not found] Meba Earth Leakage Current device MBR2 open a circuit automatically in the event of an earth fault between phase and earth and/or netural and earth. A wide range of current ratings and sensitivities are available. Suitable for domestic, commercial and industrial applications

Categories
Front Board Mounted KWH Meters

Meba kwh meter MB011GC

Application

Meba kwh meter MB011GC is a kind of new style single phase two wire active energy meter, it adopt micro-electronics technique, and imported large scale integrate circuit, use advanced technique of digital and SMT techniques, etc. The meter completely accord with relevant technical requirements of class 1 single phase active energy meter stipulated in international standard IEC 62053-21. It can accurate and directly measure 50Hz or 60Hz active energy consumption from single phase AC electricity net. This meter has seven digits LCD displays shows the active energy consumption. It has following features: good reliability, small volume, light weight, and there are far infrared and RS485 communication module in it. Contact with all kind of AMR system conveniently. It has following features: Good reliability, small volume, light weight, specious nice appearance, convenient installation, etc. This meter has already got the patent certificate from China State Intellectual Property Office at present. Patent certificate NO. ZL 2006 3 0106828.1, any other country patent certificate are in assessing.
Technical Data

 

Model Accuracy Reference Voltage(V) Current specifications(A) Starting current(A) Insulation performance
MB011GC Class 1 127
230
5(30)
10(50)
20(100)
0.02
0.04
0.08
AC voltage 4kv for 1 minute,
1.2/50us  waveform
impulse voltage 6kv

Installing Diagram

Dimensions 

Dimension for MB011
Dimension for MB011

Wiring Diagram

wiring diagram for MB011
wiring diagram for MB011

 

1. 35mm standard DIN rail installation, complying with standard DIN EN50022. Or front board setting (mounting holes center distance 63 mm), users can choose any one by themselves.
2. Six pole width (Modulus 12.5mm), complying with standard JB/T7121-1993.
3. May select 6+1 digits display (999999.1kWh) or 5+2 digits display, it can be arbitrary set by users from far infrared or port of RS485 data communication.
4. Standard configuration one port of pulse output passive (polarity), May select increase a distant port of pulse output passive (nonpolarity), complying with standard IEC 62053-31.
5. There are a port of far infrared data communication and a port of RS485 data communication. Standard configuration communication agreement complying with standard DL/T645-1997, can also choose any other communication agreement.
6. Three LED instructions power supply state, signal of energy impulse and communication state.
7. Standard configuration don’t detection direction of the flow of load current. May select automatic detection the direction of the flow of load current. And instructions by an individual LED.
8. Single direction measure single phase two wire active energy consumption. It is nothing with direction of the flow of load current. Complying with standard IEC 62053-21.
9. Standard configuration type S wiring (Inlet from bottom, outlet from top) for direct connect operation, we can also choose another type of connection, and use CT (Product Configuration code is FC) and PT & CT (Product Configuration code is EC) for operation.
10. Standard configuration short terminals cover, may select extension terminals cover, in order to protect to use safety. (Product Configuration code is GF).

[Download not found]
Categories
Residual Current Circuit Breaker

Meba Residual Current Measurement MBEFI 4P

1. Residual current circuit breakers MBEFI are used for protection against indirect touching of parts under voltage.

2. For prevention of lasting voltage on earthed parts which should appear because of a defect in the electrical installation and for protection against direct contacts of parts under voltage in case of I n 30mA.

3. Residual current circuit breakers can be used in TN-S, TN-C, TT and IT network systems or with other words in all systems where neutral and protective conductor are separated (VDE 0100 Teil 410).

4. Types – Our programme comprises residual current circuit breakers which are sensitive to alternating residu al current (AC-type) and residual current circuit breakers which are sensitive to alternating and pulsating direct current (A-type).

Merits:

Good quality , high breaking capability, updated structure,quick trip and guide installation, competitive price,excellent and safe performance,beautiful and compact appearance, etc .

MBEFI2 MBEFI4
type A type AC type G type A type AC type S type G
For alternating residual current
For alternating and pulsating direct residual current
Short-circuit capacity with back-up fuse
VDE 0664, part 1(up to 80A)
lower temperature limit of application -25℃
Selective (time delayed min. 40 ms)
Short time delayed (min. 10 ms)

MBEFI-4 type A, MBEFI-4 type AC

In [A] IΔn [A] number of poles code No.A code No.AC weight [g] packaging [pcs]
16 0,03 4 002062541 002062141 393 1/27
25 0,03 4 002062542 002062142 393 1/27
40 0,03 4 002062543 002062143 393 1/27
63 0,03 4 002062544 002062144 400 1/27
80 0,03 4 002062545 002062145 407 1/27
100 0,03 4 002062546 002062146 407 1/27
16 0,1 4 002063541 002063141 393 1/27
25 0,1 4 002063542 002063142 393 1/27
40 0,1 4 002063543 002063143 393 1/27
63 0,1 4 002063544 002063144 400 1/27
80 0,1 4 002063545 002063145 407 1/27
100 0,1 4 002063546 002063146 407 1/27
16 0,3 4 002064541 002064141 364 1/27
25 0,3 4 002064542 002064142 364 1/27
40 0,3 4 002064543 002064143 364 1/27
63 0,3 4 002064544 002064144 372 1/27
80 0,3 4 002064545 002064145 372 1/27
100 0,3 4 002064546 002064146 372 1/27
16 0.5 4 002065541 002065141 364 1/27
25 0,5 4 002065542 002065142 364 1/27
40 0,5 4 002065543 002065143 364 1/27
63 0,5 4 002065544 002065144 372 1/27
80 0,5 4 002065545 002065145 372 1/27

* type with N-pole on the left side is also available.

MBEFI-4 type S

In [A] IΔn [A] number of poles code No.AC weight [g] packaging [pcs]
40 0,3 4 002064243 400 1/27
63 0,3 4 002064244 400 1/27

MBEFI-4 type G

In [A] IΔn [A] number of poles code No.AC weight [g] packaging [pcs]
40 0,03 4 002062743* 320 1/27
40 0,1 4 002063743* 320 1/27

*The same housing as MBEFI-4 100 A.

download id=”88″]Meba Residual Current Measurement MBEFI 4P a wide range of current ratings and sensitivities are available. Suitable for domestic, commercial and industrial applications.

Categories
Residual Current Circuit Breaker

Meba Residual Current Device Operation MBEFI 2P

1. Residual current circuit breakers MBEFI are used for protection against indirect touching of parts under voltage.

2. For prevention of lasting voltage on earthed parts which should appear because of a defect in the electrical installation and for protection against direct contacts of parts under voltage in case of I n 30mA.

3. Residual current circuit breakers can be used in TN-S, TN-C, TT and IT network systems or with other words in all systems where neutral and protective conductor are separated (VDE 0100 Teil 410).

4. Types – Our programme comprises residual current circuit breakers which are sensitive to alternating residu al current (AC-type) and residual current circuit breakers which are sensitive to alternating and pulsating direct current (A-type).

Merits:

Good quality , high breaking capability, updated structure,quick trip and guide installation, competitive price,excellent and safe performance,beautiful and compact appearance, etc .

MBEFI2 MBEFI4
type A type AC type G type A type AC type S type G
For alternating residual current
For alternating and pulsating direct residual current
Short-circuit capacity with back-up fuse
VDE 0664, part 1(up to 80A)
lower temperature limit of application -25℃
Selective (time delayed min. 40 ms)
Short time delayed (min. 10 ms)

MBEFI-2 type A, MBEFI-2 type AC

In [A] IΔn [A] number of poles code No.A code No.AC weight [g] packaging [pcs]
16 0,03 2 002062521 002062121 229 1/54
25 0,03 2 002062522 002062122 229 1/54
40 0,03 2 002062523 002062123 229 1/54
63 0,03 2 002062524 002062124 244 1/54
80 0,03 2 002062525 002062125 244 1/54
100 0,03 2 002062126 244 1/54
16 0,1 2 002063521 002063121 223 1/54
25 0,1 2 002063522 002063122 223 1/54
40 0,1 2 002063523 002063123 223 1/54
63 0,1 2 002063524 002063124 227 1/54
80 0,1 2 002063525 002063125 230 1/54
100 0,1 2 002063526 230 1/54
16 0,3 2 002064521 002064121 223 1/54
25 0,3 2 002064522 002064122 223 1/54
40 0,3 2 002064523 002064123 223 1/54
63 0,3 2 002064524 002064124 227 1/54
80 0,3 2 002064525 002064125 230 1/54
100 0,3 2 002064526 002064126 230 1/54
16 0.5 2 002065521 002065121 223 1/54
25 0,5 2 002065522 002065122 223 1/54
40 0,5 2 002065523 002065123 223 1/54
63 0,5 2 002065524 002065124 227 1/54
80 0,5 2 002065525 002065125 230 1/54

MBEFI-2 type G

In [A] IΔn [A] number of poles code No.AC weight [g] packaging [pcs]
25 0,03 2 002062722* 220 1/54
25 0,1 2 002063722* 220 1/54
40 0,3 2 002062723* 220 1/54
40 0,1 2 002063723* 220 1/54

*The same housing as MBEFI-2 100 A.

[Download not found]Meba Residual Current Device Operation MBEFI 2P a wide range of current ratings and sensitivities are available. Suitable for domestic, commercial and industrial applications.

Categories
Residual Current Circuit Breaker

Meba RCCB RCBO MBEA-63A

Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: MBACH2
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 2P

Application:

1. MBEA-63A RCCB provide the function of isolation switching and earth leakage protection of electrical circuits.

2. They open a circuit automatically in the event of an earth fault be tween phase and earth and/or neutral and earth.

3. A wide range of current ratings and sensitivities are available. Suitable for domestic, commercial and industrial applications.

 

Merits:

Good quality , high breaking capability, updated structure,quick trip and guide installation, competitive price,excellent and safe performance,beautiful and compact appearance, etc .

Mounting Requirements:

1. Circumstance temperature -5°C ~ +40°C, average temperature not exceeding 35°C.
2. Altitude above sea level less than 2000 m.
3. Humidity not exceeding 50% at 40°C and not exceeding 90% at 25°C.
4. Installation class II or III.
5. Pollution class 2.
6. Installation method DIN Rail mounting type.
7. The external magnetism shall not be more than 5 times of terrestrial one.
8. Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position.

Rated Voltage

1Pole+N: 230/240V AC, 3Pole+N: 400/415V AC

 Rated Current

10, 16, 20, 25, 32, 40A, 50A, 63A

 Rated Frequency

 50/60Hz

 Rated Residual Operating Current

 30, 100, 300, 500mA

Rated residual non-operating current(I no)

 0.5ls n

 Rated Circuit Breaking Capacity

 6KA

Residual current off-time

0.1S

Operating temperatur2

-5 to +55℃

Standard

IEC61008-1

[Download not found]Meba RCCB RCBO MBEA-63A open a circuit automatically in the event of an earth fault between phase and earth and/or netural and earth. A wide range of current ratings and sensitivities are available. Suitable for domestic, commercial and industrial applications.

Categories
Residual Current Circuit Breaker

Meba Current Leakage Detection MBB8LE

Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: MBB8LE-63
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 2 pole MCB + ELCB

Application:

1. MBB8LE-63 2Pole, combination by mini circuit breaker and leakage.

2. Which protect human from the fault of electric because of over-current, short circuit, earth fault current. It is self-protecting up to a maximum short-circuit current 63A.

3. All breaking capacities comply with Standard IEC/EN 61009.

Merits:

Good quality , high breaking capability, updated structure,quick trip and guide installation, competitive price,excellent and safe performance,beautiful and compact appearance, etc .

Mounting Requirements:

1. Circumstance temperature -5°C ~ +40°C, average temperature not exceeding 35°C.
2. Altitude above sea level less than 2000 m.
3. Humidity not exceeding 50% at 40°C and not exceeding 90% at 25°C.
4. Installation class II or III.
5. Pollution class 2.
6. Installation method DIN Rail mounting type.
7. The external magnetism shall not be more than 5 times of terrestrial one.
8. Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position.

1. Residual current device with overcurrent protection
2. Combine in residual current device function and MCB over-current protection function
3. Short circuit capacity: 6KA
4. Rated current(A): 6,16,20,25,32,40,50,63A
5. Rated leakage operating current(mA): 30,100,300mA
6. AC types, B-C characteristic
7. Modular Din Rail products 35mm.

[Download not found]Meba Current Leakage Detection MBB8LE-63-2P open a circuit automatically in the event of an earth fault between phase and earth and/or netural and earth. A wide range of current ratings and sensitivities are available. Suitable for domestic, commercial and industrial applications.

Categories
Residual Current Circuit Breaker

Meba Earth Leakage Protection MBB8LE-63-1P

Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: MBB8LE-63
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 1 pole MCB + ELCB

Application:

1. MBB8LE-63 1Pole, combination by mini circuit breaker and leakage.

2. Which protect human from the fault of electric because of over-current, short circuit, earth fault current. It is self-protecting up to a maximum short-circuit current 63A.

3. All breaking capacities comply with Standard IEC/EN 61009.

Merits:

Good quality , high breaking capability, updated structure,quick trip and guide installation, competitive price,excellent and safe performance,beautiful and compact appearance, etc .

Mounting Requirements:

1. Circumstance temperature -5°C ~ +40°C, average temperature not exceeding 35°C.
2. Altitude above sea level less than 2000 m.
3. Humidity not exceeding 50% at 40°C and not exceeding 90% at 25°C.
4. Installation class II or III.
5. Pollution class 2.
6. Installation method DIN Rail mounting type.
7. The external magnetism shall not be more than 5 times of terrestrial one.
8. Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position.

1. Residual current device with overcurrent protection
2. Combine in residual current device function and MCB over-current protection function
3. Short circuit capacity: 6KA
4. Rated current(A): 6,16,20,25,32,40,50,63A
5. Rated leakage operating current(mA): 30,100,300mA
6. AC types, B-C characteristic
7. Modular Din Rail products 35mm.

[Download not found]Meba Earth Leakage Protection MBB8LE-63-1P open a circuit automatically in the event of an earth fault between phase and earth and/or netural and earth. A wide range of current ratings and sensitivities are available. Suitable for domestic, commercial and industrial applications.

Categories
Din-Rail Mounted Energy Meters

Meba-smart energy meter-MB011

Application

Meba smart energy meter MB011 is a kind of new style single phase two wire active energy meter, it adopt micro-electronics technique, and imported large scale integrate circuit, use advanced technique of digital and SMT techniques, etc. The meter completely accord with relevant technical requirements of class 1 single phase active energy meter stipulated in international standard IEC 62053-21. It can accurate and directly measure 50Hz or 60Hz active energy consumption from single phase AC electricity net. This meter has seven digits LCD displays shows the active energy consumption. It has following features: good reliability, small volume, light weight, and there are far infrared and RS485 communication module in it. Contact with all kind of AMR system conveniently. It has following features: Good reliability, small volume, light weight, specious nice appearance, convenient installation, etc. This meter has already got the patent certificate from China State Intellectual Property Office at present. Patent certificate NO. ZL 2006 3 0106828.1, any other country patent certificate are in assessing.[/acc_item]
Technical Data

 

Model Accuracy Reference Voltage(V) Current specifications(A) Starting current(A) Insulation performance
MB011 Class 1 127
230
5(30)
10(50)
20(100)
0.02
0.04
0.08
AC voltage 4kv for 1 minute,
1.2/50us  waveform
impulse voltage 6kv

Installing Diagram

Dimensions 

Dimension for MB011
Dimension for MB011

Wiring Diagram

wiring diagram for MB011
wiring diagram for MB011

1. 35mm standard DIN rail installation, complying with standard DIN EN50022. Or front board setting (mounting holes center distance 63 mm), users can choose any one by themselves.
2. Six pole width (Modulus 12.5mm), complying with standard JB/T7121-1993.
3. May select 6+1 digits display (999999.1kWh) or 5+2 digits display, it can be arbitrary set by users from far infrared or port of RS485 data communication.
4. Standard configuration one port of pulse output passive (polarity), May select increase a distant port of pulse output passive (nonpolarity), complying with standard IEC 62053-31.
5. There are a port of far infrared data communication and a port of RS485 data communication. Standard configuration communication agreement complying with standard DL/T645-1997, can also choose any other communication agreement.
6. Three LED instructions power supply state, signal of energy impulse and communication state.
7. Standard configuration don’t detection direction of the flow of load current. May select automatic detection the direction of the flow of load current. And instructions by an individual LED.
8. Single direction measure single phase two wire active energy consumption. It is nothing with direction of the flow of load current. Complying with standard IEC 62053-21.
9. Standard configuration type S wiring (Inlet from bottom, outlet from top) for direct connect operation, we can also choose another type of connection, and use CT (Product Configuration code is FC) and PT & CT (Product Configuration code is EC) for operation.
10. Standard configuration short terminals cover, may select extension terminals cover, in order to protect to use safety. (Product Configuration code is GF).

[Download not found]
Categories
Residual Current Circuit Breaker

Meba Rccb Circuit Breaker MBACH2

Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: MBACH2
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 2P

Application:

1. MBACH2 RCCB provide the function of isolation switching and earth leakage protection of electrical circuits.

2. They open a circuit automatically in the event of an earth fault between phase and earth and/or neutral and earth. A wide range of current ratings and sensitivities are available.

3. Suitable for domestic, commercial and industrial applications.

Merits:

Good quality , high breaking capability, updated structure,quick trip and guide installation, competitive price,excellent and safe performance,beautiful and compact appearance, etc .

Mounting Requirements:

1. Circumstance temperature -5°C ~ +40°C, average temperature not exceeding 35°C.
2. Altitude above sea level less than 2000 m.
3. Humidity not exceeding 50% at 40°C and not exceeding 90% at 25°C.
4. Installation class II or III.
5. Pollution class 2.
6. Installation method DIN Rail mounting type.
7. The external magnetism shall not be more than 5 times of terrestrial one.
8. Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position.

Rated Voltage

1Pole+N: 230/240V AC, 3Pole+N: 400/415V AC

 Rated Current

10, 16, 20, 25, 32, 40A

 Rated Frequency

 50/60Hz

 Rated Residual Operating Current

 30, 100, 300, 500mA

Rated residual non-operating current(I no)

 0.5ls n

 Rated Circuit Breaking Capacity

 4.5KA

Residual current off-time

0.1S

Operating temperatur2

-5 to +55℃

Standard

IEC61008-1

[Download not found]Meba Rccb Circuit Breaker MBACH2 open a circuit automatically in the event of an earth fault between phase and earth and/or netural and earth. A wide range of current ratings and sensitivities are available. Suitable for domestic, commercial and industrial applications.

Categories
Residual Current Circuit Breaker

Meba Electrical rccb wiring MB7L2-63

Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: MB7L2-63
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 2P

Application:

1. MB7L2-63 series Residual current breaker(without over-current protection) is suitable for the line of AC 50/60Hz, voltage 240V(2 pole)/415V(4 pole),rated current up to 80A.

2. When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will cut off the power rapidly to protect human safety and prevent the accident due to the current leakage .

3. It is applicable to industrial area, commercial area, tall building and civil house.

Merits:

Good quality , high breaking capability, updated structure,quick trip and guide installation, competitive price,excellent and safe performance,beautiful and compact appearance, etc .

Mounting Requirements:

1. Circumstance temperature -5°C ~ +40°C, average temperature not exceeding 35°C.
2. Altitude above sea level less than 2000 m.
3. Humidity not exceeding 50% at 40°C and not exceeding 90% at 25°C.
4. Installation class II or III.
5. Pollution class 2.
6. Installation method DIN Rail mounting type.
7. The external magnetism shall not be more than 5 times of terrestrial one.
8. Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position.

Rated Voltage

 240/415V

 Rated Current

 16,25,40,63,80A

 Rated Frequency

 50/60Hz

 Rated Residual Operating Current

 0.03,01,0.3,0.5A

 Rated Short Circuit Current

 In ≤  50A  500A    In ≤ 63A 630A

 Rated Circuit Breaking Capacity

 6KA

 Mechanical Life

 10000times

 Electric Life

 4000times

Standard

IEC61008-1

Operation Principle Figure:

Dimension:


 

 

 

[Download not found]Meba Electrical rccb wiring MB7L2-63 open a circuit automatically in the event of an earth fault between phase and earth and/or netural and earth. A wide range of current ratings and sensitivities are available. Suitable for domestic, commercial and industrial applications.

Categories
Residual Current Circuit Breaker

Meab MCB RCCB ELCB RCBO MCCB RCD MB7L4-63

Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)
Brand Name: Meba
Model Number: MB7L2-63
Type: Residual Current Circuit Breaker or Residual Current Device
Poles Number: 2P

Application:

1. MB7L2-63 series Residual current breaker(without over-current protection) is suitable for the line of AC 50/60Hz, voltage 240V(2 pole)/415V(4 pole),rated current up to 80A.

2. When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will cut off the power rapidly to protect human safety and prevent the accident due to the current leakage .

3. It is applicable to industrial area, commercial area, tall building and civil house.

Merits:

Good quality , high breaking capability, updated structure,quick trip and guide installation, competitive price,excellent and safe performance,beautiful and compact appearance, etc .

Mounting Requirements:

1. Circumstance temperature -5°C ~ +40°C, average temperature not exceeding 35°C.
2. Altitude above sea level less than 2000 m.
3. Humidity not exceeding 50% at 40°C and not exceeding 90% at 25°C.
4. Installation class II or III.
5. Pollution class 2.
6. Installation method DIN Rail mounting type.
7. The external magnetism shall not be more than 5 times of terrestrial one.
8. Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position.

Rated Voltage

 240/415V

 Rated Current

 16,25,40,63,80A

 Rated Frequency

 50/60Hz

 Rated Residual Operating Current

 0.03,01,0.3,0.5A

 Rated Short Circuit Current

 In ≤  50A  500A    In ≤ 63A 630A

 Rated Circuit Breaking Capacity

 6KA

 Mechanical Life

 10000times

 Electric Life

 4000times

Standard

IEC61008-1

Operation Principle Figure:

Dimension:


[Download not found]Meab MCB RCCB ELCB RCBO MCCB RCD MB7L4 open a circuit automatically in the event of an earth fault between phase and earth and/or netural and earth. A wide range of current ratings and sensitivities are available. Suitable for domestic, commercial and industrial applications.