Categories
Photoelectric Switch

Meba Photoelectric Switch G12

Model explanation of proximity switch:

Meba G12 model

 

Number Composition Code and Definition
1 Switch catalogue G: Photoelectric sensor
2 Outward appearance code ■: Cylinder type;
F: Angular column type and plane installation type
3 Working voltage 2: 90-250VAC ;3: 10-30VDC;
4: 12-240VDC/24-240VAC; 5: Special voltage
4 Detection distance 05: 5cm ; 10: 10cm; 30: 30cm; 101: 10m
5 Output form N: Three-line DC NPN output; P: Three-line DC PNP output;
L: Two-line DC output; ■: AC two-wire output;
J: Relay output; NP: NPN+PNP output
6 Output state A: NO; B: NC; C: NO+NC; MU: Mimic voltage; MI: Mimic current
7 Subsidiary functions T: With connector; Y: Water proof, oil proof;
I: Special requirement; H: High temp resistance; R: Ring type

 

Briefintroduction:

SM series Hall sensor is a kind of magnet sensitive sensor consisting of voltage regulator, Hall voltage generator, differential amplifier Schmidt trigger and the output pole of collector open circuit. Its input is the magnetic flux density. The output is a digital voltage signal.

Main features:

– Compact volume

– high precision of repeated location

– Diversified exterior structures

– Good performance of anti-interference.

– Many output forms

– High on-off frequency

– Wide voltage range

– Dust proof,vibration proof,water proof and oil proof.

– With short-circuit protection and inverted connecting protection.

– Long service life

 Technical Parameter(Photoelectric Switch G12):

Model NO. Detection distance Working voltage Output Detection way
Form State
G12 -3A 07NA 7cm DC10-30V NPN NO Diffuse type
G12 -3A 07NB 7cm DC10-30V NPN NC Diffuse type
G12 -3A 07PA 7cm DC10-30V PNP NO Diffuse type
G12 -3A 07PB 7cm DC10-30V PNP NC Diffuse type
G12-3B1NA 1m DC10-30V NPN NO Retroreflective
G12-3B1NB 1m DC10-30V NPN NC Retroreflective
G12-3B1PA 1m DC10-30V PNP NO Retroreflective
G12-3B1PB 1m DC10-30V PNP NC Retroreflective
G12 -3C 3NA 3m DC10-30V NPN NO Through beam
G12 -3C 3NB 3m DC10-30V NPN NC Through beam
G12 -3C 3PA 3m DC10-30V PNP NO Through beam
G12 -3C 3PB 3m DC10-30V PNP NC Through beam
Categories
Photoelectric Switch

Meba Through Beam Photoelectric Sensor BX15M-MFR

Tech Parameter

Model BX15M-TFR BX5M-MFR BX700-DFR
Detect distance 15m 0.1-5m 700mm
Detect target Opaque materials of Min 16mm Opaque materials of Min 60mm Transparent, translucent, opaque material
Hysterisis ———— ———— 20% Max, at detecting distance
Response time Max 20mS Max 20mS Max 20mS
Power voltage AC24-240V  DC24-240V AC24-240V  DC24-240V AC24-240V  DC24-240V
Sensitivity ———— ———— Adjustable by VR
Operating mode Light on/off select by slide switch
Control output Relay output Capacity:30VDC 3AResistive load,250VAC 3A Resistive load
Contact orde:1C
Protection IP54 IP54 IP54

Using Cautions

Meba Through Beam Photoelectric Sensor BX15M-MFR Method of anti mutual-interference and cautions:

■Mutual cross installation of optic projector and photo-receptor.

■When using reflection type in parallel, the mutual spacing should be kept at over 1.4 times detection distance.

■The mains voltage should be within the range of operating.

■The following installation occasions will result in error action, take note of:

1. Dusty occasion

2. The occasion with corrosive gas

3. The occasion directly spattered with water, oil and agent etc

4. Outdoor or the occasion directly shine by hard light like sunlight

Categories
Photoelectric Switch

Meba Photoelectric Sensor G50-4A50JC

Photoelectric Sensor G50-4A50JC Series

MPDEL

      G50-4C10JC

    G50-4B5JC

    G50-4A50JC

Type

Through Beam

Retroreflective

Diffuse Type

  Detect distance

           10m

     0.1-5m

      500mm

  Detect target

  Opaque materials of Min 16mm

  Opaque materials of Min 60mm

 Transpqrent, translucent, opaque materials

  Hysterisis

      ————

      —————

  20% Max, at detecting distance

  Response time

        Max 20mS

         Max 20mS

 Max 20mS

  Power voltage

   AC 24-240V     DC 24-240V

    AC 24-240V     DC 24-240V

   AC 24-240V     DC 24-240V

  Sensitivity

     ————

        —————-

   Adjustable by VR

  Operating mode

     Light on/off select by slide switch

      Light on/off select by slide switch

     Light on/off select by slide switch

  Control output

      Relay output

 Relay output

 Relay output

  Protection

         IP54

           IP54

        IP54

 

Method of anti mutual-interference and cautions:

■Mutual cross installation of optic projector and photo-receptor.

■When using reflection type in parallel, the mutual spacing should be kept at over 1.4 times detection distance.

■The mains voltage should be within the range of operating.

■The following installation occasions will result in error action, take note of:

1. Dusty occasion

2. The occasion with corrosive gas

3. The occasion directly spattered with water, oil and agent etc

4. Outdoor or the occasion directly shine by hard light like sunlight