Categories
Cam Switch

Meba LW28A(LW39A) Rotary Switch

Meba LW28A(LW39A) Rotary Switch is the development of new universal change Switch and the product pleasing.Very convenient wiring, the internal movements of all components are designed bearings, and so moves feeling very Sophie,Switchlife longer applicable to the exchange of products 50-60Hz voltage 690V and below.DC 440V and the following circuit can be used in high voltage electrical machinery, machine tools, electrical equipment, as well as modern Chinese intelligent packages.
Normal working conditions:

1. Ambient air temperature does not exceed +40, and the average temperature does not exceed its 24 +35;
2. ambient air temperature does not exceed the limit of -5;
3. installation location at an altitude of less than 2000m;
4.+40 maximum temperature, relative humidity of the air does not exceed 50%.at a lower temperature can allow a higher relative humidity.For example, when 90% of 20. Temperature changes due to the Dewing occasional special measures to be taken. GLE9 series Switchspecifications complete,20A,25A,32A,63A there.Current grades such as 125A and 160A.Switchspecifications past, a single universal change, Rated current small,Only 16A.GLE9 Series Switch is small in size, function, compact structure, material stress.

Meba LW28A(LW39A) Rotary Switch

Specifications:
Meet standards:Circuit switch used to control and direct conversion Switch with GB14048.3-1993 use. Use master control switchSwitchWithGB14048.5-1993.

3.1 Use master control switch Models Meaning

LW28A_1

3.2 Use master control switch Models Meaning

LW28A_2

Note : The direct conversion Switch control motors commonly used 60 change.

LW28A_LW39A-Rotary-Switch_

Categories
Cam Switch

Meba GLE9 Rotary Switch

Meba GLE9 Rotary Switch  introducing of the Italian first led to the development of new productssmall size, access to domestic and breaking capacity over the conversion,Switch mainly used for three different sets of electrical appliances Switch counters or less variable speed motor load starting to change, as well as the main circuit and auxiliary circuit usedSwitch can be replaced by all the change.

Normal working conditions
1. Ambient air temperature does not exceed +40, and the average temperature does not exceed its 24 +35;
2. Ambient air temperature does not exceed the limit of -5;
3. Installation location at an altitude of less than 2000m;
4.+40 maximum temperature, relative humidity of the air does not exceed 50%.at a lower temperature can allow a higher relative humidity.For example, when 90% of 20. Temperature changes due to the Dewing occasional special measures to be taken. GLE9 series Switchspecifications complete,20A,25A,32A,63A there.Current grades such as 125A and 160A.Switchspecifications past, a single universal change, Rated current small,Only 16A.GLE9 Series Switch is small in size, function, compact structure, material stress.

Meba GLE9 Rotary Switch

Specifications:

The table gives the conversion of the Main Switch technical parameters.

Mode of operation Code Conversion point cod
Since A 0← 30 →0← 45
B 30 0 30 45 →0← 45
location C 0 30 →0← 45
D 30 0 30 45 →0← 45
E 30 0 30 60 45 →0← 45
F 60 30 0 30 60 90 45 →0← 45
G 60 30 0 30 60 90 90 45 →0← 45
H 90 60 30 0 30 60 90 135 90 45 →0← 45
I 90 60 30 0 30 60 90 120 135 90 45 →0← 45
J 120 90 60 30 0 30 60 90 120
K 120 90 60 30 0 30 60 90 120 150
L 150 120 90 60 30 0 30 60 90 120 150
M 150 120 90 60 30 0 30 60 90 120 150 180
N 45 45
Since the Positioning REPLICA Z 30 →0← 60 90 →0← 45
135 90 →0← 45

Mode of operation Code Conversion point code
Since A
B
location C 0 60 0 90
D 60 0 60 90 0 90
E 90 90 30 30 90 90 0 90 180
F 90 90 30 30 90 150
G 90 135 150 90 30 30 90 150
H 90 135
I 90 135 180
J
K
L
M
N 30 30
Since the Positioning REPLICA Z

Models lth
A
Ui
V
Ue
V
AC-21A AC-22A AC-23A AC-2 AC-3 AC-4 AC-15 DC-13
Le
A
Le
A
Le
A
p
kw
Le
A
p
kw
Le
A
p
kw
Le
A
p
kw
Le
A
Le
A
GLE9-20 20 660 440 20 20 15 7.5 15 7.5 11 5.5 3.5 1.5 4  
240                       1
120                        
GLE9-25 25 440 25 25 22 11 22 11 15 7.5 6.5 3 5 5
240                     8 1.5
120                       9
GLE9-32 32 440 32 32 30 15 30 15 22 11 11 5.5 6  
240                     14 11
120                       25
GLE9-75 75 440 75 75 72 30 72 30 32 24 23 11.5    
120                       60
GLE9-125 125 440 125 125 90 45 90 45 36 45 30 18.5    
Operation Cycle Unladen 8500 Life(Meeting)
Unladen 1500 20104 6104
Mechanical life
Unladen 1000 60104
Categories
Cam Switch

Meba GLD LW12 Rotary Switch

Meba GLD LW12 Rotary Switch Series Universal Conversion Switch mainly for the exchange of 50Hz.Rated voltage380V and below.220V DC voltage conversion circuit and the following electrical control circuits and electrical measuring instrument Table.5.5KW can directly control and the following three-phase squirrel cage induction motor.

Meba GLD LW12 Rotary Switch

Specifications:

4.1By Uses pm with a master control switch Switch and motor control using direct conversion Switch.
4.2By Mode of Have an operationLocation ,Since REPLICA,Since REPLICA GPS positioning and a half since the belt locking device -System .
4.3 contact hours by :Use a master control switchSwitch 1-12 festival, a total of 12;Switch direct control of the main electrical switch using 2, 3, 4 and 6, a total of four.
4.4By Mode of Have an Operation30, 45 and 90 Four.

Mode of
Operation
Feature
Code
Operating position
Since REPLICA A 0←45
B 45→0←45
Location C 0 45
D 45 0 45
E 45 0 45 90
F 90 45 0 45 90
G 90 45 0 45 90 135
H 135 90 45 0 45 90 135
I 135 90 45 0 45 90 135 180
J 120 90 60 30 0 30 60 90 120
K 120 90 60 30 0 30 60 90 120 150
L 150 120 90 60 30 0 30 60 90 120 150
M 150 120 90 60 30 0 30 60 90 120 150 180
N 45 45
P 0 90
90 0
90 0 90
R 0 90 270
Z 45 0←45
90 0←45
90 45 0 45←      90
135→90 0←45
Since
belt-positioning
debvice
Zl 45→0←45 90
90 45→0←45
90 45→0←45 90

Ui
V
Ith
A
Ue
V
Ie
A
Mechanical life
Meeting
Life
Meeting
Operating frequency
Meeting/h
AC-15 500 16 380 2.60 100×104 20104 300
DC-13 220 4.60 20104
AC-3 220 0.27 1.95104 Total
20104
300
AC-4 380 12 0.5104 120
Categories
Cam Switch

Meba-CS-68-Rotary-Switch

Meba CS 68 Rotary Switch could be widely applied.Power Switch use, as is high voltage,Therefore, we should use current high silver alloy contact in the CNC control panel.Low voltage is due, it should be current use of the low end.Because they use different they may be a clear distinction, and general products have not been possible to clear labeling.Resettlement rate or damage caused by natural increase have access to the insensitivity of view.The power company is the introduction of other types as applicable Of-Switch to distinguish between blue and two high-voltage color.high current and low voltage, low current period results can be reached work, and enhance product life.

Meba CS 68 Rotary Switch

Rated Radio Table:

Low voltage, low current
(Contact Block said a white Table)
High voltage, high current
(Contact Block said a white Table)
Then little capacity 24V      0.1A 600V     15A
Contact resistance Following early 10m Ω Following early 50m Ω
Withstand voltage 2200VAC                One minute
Insulation resistance 10mΩ以上          500VAC
life Machinery back above 100,000 :
Electrical back above 100,000 :

Mode of operation Revert to manual Automatic Return
Switching angle 30, 45, 60, 90 45
Switching of a few 2-12Of 2-3Of

Fixed Hole Size

Repeated Meeting 1 2 3 4 5 6 7 8 9 10
A/Rated Radio Table 40 55.5 71.5 6.5 102 11 133 148 164 179