Categories
Proximity Switch

Meba Potentiometer Sensor LM8-T3

Model explanation of proximity switch:

Number Composition Code and Definition
1 Switch catalogue LM: inductance type; CM: capactitance type; SM:Hall type;
AM:safety explosion- proof type; XM: mimic linear type
2 Outward appearance code ■: Cylinder type;
F: Angular column type and plane installation type
3 Working voltage 30: 6-36VDC; 310: 5-24VDC; 320: 12-60VDC;
20: 90-250VAC; 210: 24-250VAC; 220: 380VAC;
40: 12-240VDC/24-240AC; 50: Special voltage
4 Detection distance 01: 1mm; 05:5mm; 10:10mm
5 Output form N: Three-line DC NPN output; P: Three-line DC PNP output;
L: Two-line DC output; ■: AC two-wire output;
J: Relay output; NP: NPN+PNP output
6 Output state A: NO; B: NC; C: NO+NC; MU: Mimic voltage; MI: Mimic current
7 Subsidiary functions T: With connector; Y: Water proof, oil proof;
I: Special requirement; H: High temp resistance; R: Ring type

 

Main features:

– Compact volume

– high precision of repeated location

– Diversified exterior structures

– Good performance of anti-interference.

– Many output forms

– High on-off frequency

– Wide voltage range

– Dust proof,vibration proof,water proof and oil proof.

– With short-circuit protection and inverted connecting protection.

– Long service life

 Technical parameter(Potentiometer Sensor LM8-T3):

Model NO. Detection distance Working voltage Output Flush
Form State
LM8-3001NAT3 1mm DC6-36V NPN NO Flush
LM8-3001NBT3 1mm DC6-36V NPN NC Flush
LM8-3001PAT3 1mm DC6-36V PNP NO Flush
LM8-3001PBT3 1mm DC6-36V PNP NC Flush
LM8-3001LAT3 1mm DC6-36V Two wire system NO Flush
LM8-3002NAT3 2mm DC6-36V NPN NO Non-flush
LM8-3002NBT3 2mm DC6-36V NPN NC Non-flush
LM8-3002PAT3 2mm DC6-36V PNP NO Non-flush
LM8-3002PBT3 2mm DC6-36V PNP NC Non-flush
LM8-3002LAT3 2mm DC6-36V Two wire system NO Non-flush
LM8-2002AT3 2mm AC90-250V SCR Control label silicon NO Non-flush
Categories
Proximity Switch

Meba Inductive Load Switching Sensors LM8-T

Model explanation of proximity switch:

Number Composition Code and Definition
1 Switch catalogue LM: inductance type; CM: capactitance type; SM:Hall type;
AM:safety explosion- proof type; XM: mimic linear type
2 Outward appearance code ■: Cylinder type;
F: Angular column type and plane installation type
3 Working voltage 30: 6-36VDC; 310: 5-24VDC; 320: 12-60VDC;
20: 90-250VAC; 210: 24-250VAC; 220: 380VAC;
40: 12-240VDC/24-240AC; 50: Special voltage
4 Detection distance 01: 1mm; 05:5mm; 10:10mm
5 Output form N: Three-line DC NPN output; P: Three-line DC PNP output;
L: Two-line DC output; ■: AC two-wire output;
J: Relay output; NP: NPN+PNP output
6 Output state A: NO; B: NC; C: NO+NC; MU: Mimic voltage; MI: Mimic current
7 Subsidiary functions T: With connector; Y: Water proof, oil proof;
I: Special requirement; H: High temp resistance; R: Ring type

 

Main features:

– Compact volume

– high precision of repeated location

– Diversified exterior structures

– Good performance of anti-interference.

– Many output forms

– High on-off frequency

– Wide voltage range

– Dust proof,vibration proof,water proof and oil proof.

– With short-circuit protection and inverted connecting protection.

– Long service life

 Technical Parameter(Inductive Load Switching Sensors LM8-T):

Model NO. Detection distance Working voltage Output Flush
Form State
LM8-3001NAT 1mm DC6-36V NPN NO Flush
LM8-3001NBT 1mm DC6-36V NPN NC Flush
LM8-3001PAT 1mm DC6-36V PNP NO Flush
LM8-3001PBT 1mm DC6-36V PNP NC Flush
LM8-3001LAT 1mm DC6-36V Two wire system NO Flush
LM8-3002NAT 2mm DC6-36V NPN NO Non-flush
LM8-3002NBT 2mm DC6-36V NPN NC Non-flush
LM8-3002PAT 2mm DC6-36V PNP NO Non-flush
LM8-3002PBT 2mm DC6-36V PNP NC Non-flush
LM8-3002LAT 2mm DC6-36V Two wire system NO Non-flush
LM8-2002AT 2mm AC90-250V SCR Control label silicon NO Non-flush
Categories
Proximity Switch

Meba Connector Type Proximity Switch LM12-T3

Model explanation of proximity switch:

 

 

Number Composition Code and Definition
1 Switch catalogue LM: inductance type; CM: capactitance type; SM:Hall type;
AM:safety explosion- proof type; XM: mimic linear type
2 Outward appearance code ■: Cylinder type;
F: Angular column type and plane installation type
3 Working voltage 30: 6-36VDC; 310: 5-24VDC; 320: 12-60VDC;
20: 90-250VAC; 210: 24-250VAC; 220: 380VAC;
40: 12-240VDC/24-240AC; 50: Special voltage
4 Detection distance 01: 1mm; 05:5mm; 10:10mm
5 Output form N: Three-line DC NPN output; P: Three-line DC PNP output;
L: Two-line DC output; ■: AC two-wire output;
J: Relay output; NP: NPN+PNP output
6 Output state A: NO; B: NC; C: NO+NC; MU: Mimic voltage; MI: Mimic current
7 Subsidiary functions T: With connector; Y: Water proof, oil proof;
I: Special requirement; H: High temp resistance; R: Ring type

 

Main features:

– Compact volume

– high precision of repeated location

– Diversified exterior structures

– Good performance of anti-interference.

– Many output forms

– High on-off frequency

– Wide voltage range

– Dust proof,vibration proof,water proof and oil proof.

– With short-circuit protection and inverted connecting protection.

– Long service life

 

Technical Parameters:

Outward appearance code

LM12-口口T3

Flush

Detection distance

2mm

DC

6-36

VDC

NPN

NO

LM12-3002NAT3

NC

LM12-3002NBT3

NO+NC

LM12-3002NCT3

PNP

NO

LM12-3002PAT3

NC

LM12-3002PBT3

NO+NC

LM12-3002PBT3

Two wire

systerm

NO

LM12-3002LAT3

NC

LM12-3002LBT3

AC

90~250

VAC

SCR control-lable silicon

NO

LM12-2002AT3

NC

LM12-2002BT3

NO+NC

Relay output

Non-

flush

Detection distance

4mm

DC

6-36

VDC

NPN

NO

LM12-3004NAT3

NC

LM12-3004NBT3

NO+NC

LM12-3004NCT3

PNP

NO

LM12-3004PAT3

NC

LM12-3004PBT3

NO+NC

LM12-3004PCT3

Two

wire system

NO

LM12-3004LAT3

NC

LM12-3004LBT3

AC

90~250

VAC

SCR Control-lable

silicon

NO

LM12–2004AT3

NC

LM12-2004BT3

NO+NC

Relay output

Output current

DC

200mA

SCR/ Relay

200mA
Output voltage drop DC/AC DC<3V, AC<10V,  DC two wire<3.9V
Consumption current DC12V<8mA,  DC24V<8mA,  AC<10mA
Standard detected object 12*12*1 A3 Iron
Repeated precision 0.01
DC/AC Response frequency 400Hz/10Hz
Working environment temperature -25°C~+70°C
Insulation resistance 50MΩ
Shell material Metal
Protection grade IP67
Altemative model at home and abroad E2E-X2E1-M1
Categories
Photoelectric Switch

Meba Through Beam Photoelectric Sensor BX15M-MFR

Tech Parameter

Model BX15M-TFR BX5M-MFR BX700-DFR
Detect distance 15m 0.1-5m 700mm
Detect target Opaque materials of Min 16mm Opaque materials of Min 60mm Transparent, translucent, opaque material
Hysterisis ———— ———— 20% Max, at detecting distance
Response time Max 20mS Max 20mS Max 20mS
Power voltage AC24-240V  DC24-240V AC24-240V  DC24-240V AC24-240V  DC24-240V
Sensitivity ———— ———— Adjustable by VR
Operating mode Light on/off select by slide switch
Control output Relay output Capacity:30VDC 3AResistive load,250VAC 3A Resistive load
Contact orde:1C
Protection IP54 IP54 IP54

Using Cautions

Meba Through Beam Photoelectric Sensor BX15M-MFR Method of anti mutual-interference and cautions:

■Mutual cross installation of optic projector and photo-receptor.

■When using reflection type in parallel, the mutual spacing should be kept at over 1.4 times detection distance.

■The mains voltage should be within the range of operating.

■The following installation occasions will result in error action, take note of:

1. Dusty occasion

2. The occasion with corrosive gas

3. The occasion directly spattered with water, oil and agent etc

4. Outdoor or the occasion directly shine by hard light like sunlight

Categories
Photoelectric Switch

Meba Diffuse Type Photo Sensor BX700-DFR

Tech Parameter

Model BX15M-TFR BX5M-MFR BX700-DFR
Detect distance 15m 0.1-5m 700mm
Detect target Opaque materials of Min 16mm Opaque materials of Min 60mm Transparent, translucent, opaque material
Hysterisis ———— ———— 20% Max, at detecting distance
Response time Max 20mS Max 20mS Max 20mS
Power voltage AC24-240V  DC24-240V AC24-240V  DC24-240V AC24-240V  DC24-240V
Sensitivity ———— ———— Adjustable by VR
Operating mode Light on/off select by slide switch
Control output Relay output Capacity:30VDC 3AResistive load,250VAC 3A Resistive load
Contact orde:1C
Protection IP54 IP54 IP54

Using Cautions

Meba Diffuse Type Photo Sensor BX700-DFR Method of anti mutual-interference and cautions:

■Mutual cross installation of optic projector and photo-receptor.

■When using reflection type in parallel, the mutual spacing should be kept at over 1.4 times detection distance.

■The mains voltage should be within the range of operating.

■The following installation occasions will result in error action, take note of:

1. Dusty occasion

2. The occasion with corrosive gas

3. The occasion directly spattered with water, oil and agent etc

4. Outdoor or the occasion directly shine by hard light like sunlight

 

Categories
DC Products

Meba SPD for PV system

Meba SPD for PV system is for photovoltaic (PV) solar panel system protection, this DC surge arrester is equivalent to DEHN DG Y PV 1000.

CHARACTERS of photovoltaic surge arrester:

1. Consist of a base part and plug-in protection component, for using in the lightning protection zones concept at boundary 1-2

2. Core parts are metal oxide varistor components with high discharge capacity

3. Low residual voltage and quick response

4. Thermal cut off control thanks to Thermo Dynamic Control disconnector

5. Photovoltaic surge protective device without remote signaling contact for control device

6. Window indication via red mark in the inspection window

7. Photovoltaic surge protective device with low residual voltage, can be multi-parallel connected for different distribution systems DC surge arrester  FV20C/3-1000 PV is for photovoltaic (PV) solar panel system protection.

This DC surge arrester is equivalent to DEHN DG Y PV 1000.

Meba SPD for PV system

Categories
DC Products

Meba PV Fuse with holder

Meba PV Fuse with holder

Meba PV Fuse with holder

Categories
DC Products

Meba Non Polarity Circuit Breaker

Meba Non Polarity Circuit Breaker

Meba Non Polarity Circuit Breaker for DC. Operation (hereafter short for circuit-breaker) comply with GB 14048.2 Low-voltage switchgear and controlgear— Part2: Circuit-breaker. The circuit-breaker with rated voltage up to 1000V has the feature with small size, high breaking capacity, short flashover and fast closing.

Adopting special arc extinction and current-limiting system, the circuit-breaker could break fault current in DC distribution system quickly and protect PV module which is the important component in solar PV generation system from high DC inverse current and AC feedback current coming from the failure of inverter. So that the reliable service of solar PV generation system can be guaranteed. DC miniature circuit-breakers for DC. Operation (hereafter short for circuit-breaker) comply with GB 14048.2 Low-voltage switchgear and controlgear— Part2: Circuit-breakers. The circuit-breaker with rated voltage up to 1000V has the feature with small size, high breaking capacity, short flashover and fast closing.

Meba Non Polarity Circuit Breaker

Categories
DC Products

Meba DC Surge Protector

Meba DC Surge Protector

DC surge ararester  is for photovoltaic (PV) solar panel system protection, this DC surge arrester is equivalent to DEHN DG Y PV 1000.

CHARACTORS of photovoltaic surge arrester:

1. Consist of a base part and plug-in protection component, for using in the lightning protection zones concept at boundary 1-2
2. Core parts are metal oxide vristor components with high discharge capacity
3. Low residual voltage and quick response
4. Thermal cut off control thanks to Thermo Dynamic Control disconnector
5. Photovoltaic surge protective device without remote signaling contact for control device
6. Window indication via red mark in the inspection window
7. Photovoltaic surge protective device with low residual voltage, can be multi-parallel connected for different distribution systems
DC surge ararester FV20C/3-1000 PV is for photovoltaic (PV) solar panel system protection, this DC surge arrester is equivalent to DEHN DG Y PV 1000.

CHARACTORS of photovoltaic surge arrester :
1. Consist of a base part and plug-in protection component, for using in the lightning protection zones concept at boundary 1-2
2. Core parts are metal oxide vristor components with high discharge capacity
3. Low residual voltage and quick response
4. Thermal cut off control thanks to Thermo Dynamic Control disconnector
5. Photovoltaic surge protective device without remote signaling contact for control device
6. Window indication via red mark in the inspection window
7. Photovoltaic surge protective device with low residual voltage, can be multi-parallel connected for different distribution systems

Meba DC Surge Protector

Categories
DC Products

Meba DC Non Polarity Circuit Breakers

Meba DC Non Polarity Circuit Breakers

DC miniature circuit-breakers for DC. Operation (hereafter short for circuit-breaker) comply with GB 14048.2 Low-voltage switchgear and controlgear— Part2: Circuit-breakers. The circuit-breaker with rated voltage up to 1000V has the feature with small size, high breaking capacity, short flashover and fast closing.

Adopting special arc extinction and current-limiting system, the circuit-breaker could break fault current in DC distribution system quickly and protect PV module which is the important component in solar PV generation system from high DC inverse current and AC feedback current coming from the failure of inverter. So that the reliable service of solar PV generation system can be guaranteed.

Meba DC Non Polarity Circuit Breakers

Categories
Solar Combination Box

Meba Combiner Boxes for Solar

Meba Combiner Boxes for Solar  is added between PV system modules and inverters. PowerSA-SUNio provides perfect solutions to satisfy the demands of convenience installation of large-scale PV grid-connected system modules, simple maintenance and high reliability. It converges the solar cell array which is cascaded by the same specification PV array according to the range of inverter’s DC input voltage. The serial current is accurately measured, and then output through lightning protection and circuit breaker. PowerSA-SUNio meets the needs of easy and fast connection and maintenance, and high reliability. It sets alarm accuratly and locates failure semultaneous, PowerSA-SUNio measures the voltage and cell temperature of PV array, and monitors the status of lightning protection and output circuit breaker, which is a great help to remote diagnosis of running status of PV array.

Meba Combiner Boxes for Solar

Features:

IP65. Be able to fulfill external installation wall type sealed cabinet.

Input 16 PV array concurrently. 16 pairs of pulse and minus terminals, connected with special imported fuse wire each. Protect both anode and cathode with private PV HVDC fuse. Thevoltage endurance capability is above 1000VDC.

3 Pieces of specific lightnig protection for Anode and cathode. The voltage up to 1000VDC.

L World brand DC circuit breaker.

The maximum open-circuit input voltage(maximum DC voltage) is more than 1000V (including 1000V).

Adopt reliability Hall element(DC CT sensor) in the M&C module to monitor each PV array current. Set Alarm and locate failure. Communicate through RS485 port.

Independent mesurement for PV array current.

Current analysis and fault alarm.

Meature the voltage and cell temperature of PV array, and monitor the lightning protection status and output on-off state by M&C modules.

Identify its ambient to provide fuse break alarm of PV array box and send the message to local monitor system and upper monitor system.

Lightning protection for external ports.

Download data of local monitor device and analyze it.

220V input voltage or PV array box self contained power, if the latter one, there is no need of wiring for power supply.

Twistedpair shielded communication, wireless communication or carrier communication. If the last two ones, there is need of wiring for communication.

Categories
Solar Combination Box

Meba Solar PV DC Combination Box

Meba Solar PV DC Combination Box  is added between PV system modules and inverters. PowerSA-SUNio provides perfect solutions to satisfy the demands of convenience installation of large-scale PV grid-connected system modules, simple maintenance and high reliability. It converges the solar cell array which is cascaded by the same specification PV array according to the range of inverter’s DC input voltage. The serial current is accurately measured, and then output through lightning protection and circuit breaker. PowerSA-SUNio meets the needs of easy and fast connection and maintenance, and high reliability. It sets alarm accuratly and locates failure semultaneous, PowerSA-SUNio measures the voltage and cell temperature of PV array, and monitors the status of lightning protection and output circuit breaker, which is a great help to remote diagnosis of running status of PV array.

Meba Solar PV DC Combination Box

Features:

IP65. Be able to fulfill external installation wall type sealed cabinet.

Input 16 PV array concurrently. 16 pairs of pulse and minus terminals, connected with special imported fuse wire each. Protect both anode and cathode with private PV HVDC fuse. Thevoltage endurance capability is above 1000VDC.

3 Pieces of specific lightnig protection for Anode and cathode. The voltage up to 1000VDC.

L World brand DC circuit breaker.

The maximum open-circuit input voltage(maximum DC voltage) is more than 1000V (including 1000V).

Adopt reliability Hall element(DC CT sensor) in the M&C module to monitor each PV array current. Set Alarm and locate failure. Communicate through RS485 port.

Independent mesurement for PV array current.

Current analysis and fault alarm.

Meature the voltage and cell temperature of PV array, and monitor the lightning protection status and output on-off state by M&C modules.

Identify its ambient to provide fuse break alarm of PV array box and send the message to local monitor system and upper monitor system.

Lightning protection for external ports.

Download data of local monitor device and analyze it.

220V input voltage or PV array box self contained power, if the latter one, there is no need of wiring for power supply.

Twistedpair shielded communication, wireless communication or carrier communication. If the last two ones, there is need of wiring for communication.

Categories
Switchboard

Meba Power station

Meba Power station

Meba Power station

Categories
Switchboard

Meba Distribution board

Meba Distribution board

Meba Distribution board

Categories
Switchboard

Meba Switch Board

Meba Distribution board

Meba Distribution board

Categories
Switchboard

Meba Power Cabinet

Meba Distribution board

Meba Distribution board

Categories
Push Button switch

Indicator Light XB2-EV164

 Indicator Light XB2-EV164

LAY5-EV444

LAY5-EV444

 

LAY5-EV175

LAY5-EV175

 

LAY5-EA131

LAY5-EA131

 

Application

 

1. The push button LAY5 series indicator light are used in controlling circuit of AC voltage up to 660V/AC50Hz,and DC voltage below 400V.

2. It is used for controlling signal and interlocking purposes , The main body of the push buttons adopts zinc alloy and high-grade anti-flam plastic.

3. The contact adopts special silver alloy in order to enjoy the benefit of high anti-electrical erosion.

4. Our products comply with GB/T14048.1 and IEC60947-5-1,all products are CE,ISO9001,ROHS certified .

Using Condition

 

1.Surrounding temperature:-25 -+55 .
2.Air relative humidity:≤85%.
3.It can be normally work under following condition:
Vibration frequency is 2-80Hz and acceleration speed is 0.7g/h.
4.Pollution grade is 3,installation sort is 3,protection grade is up to Ip65.
5.Altitude:≤2000m

Categories
Push Button switch

Push Button Switch with LED Light SDL16-22AD

Push Button Switch with LED Light SDL16-22AD

SDL16-22AD
SDL16-22AD

SDL16-22FD
SDL16-22FD

SDL16-22CFD
SDL16-22CFD

SDL16-22CFDFG
SDL16-22CFDFG

SDL16-22ZS
SDL16-22ZS
SDL16-11YF
SDL16-11YF

SDL16 Selector Switch
•It is possible to change position of operating system. •It is possible to change position of operating system by running front cover and locker. •For the other 45o,front cover can be locked to avoid it automatically running when it is installed on the plate. •Change position of operating system. •First get rid of lock before pulling out,second run front cover,at last push it and lock front cover.

Using Condition
1.Environmental temperature : -25°C~+50°C 2.Relative humidity:≤85% 3.Altitude :≤2000m 4.Pollution grade:3 5.Installation type:3 6.Protection grade:IP55/40 7.Environmental condition :It isn’t allowed to use under the air condition caused by explosion,gas and dust of electric conduction .

Categories
Push Button switch

Mushroom Head Push Button Switch SDL16-ES542

Mushroom Head Push Button Switch SDL16-ES542

SDL16-ES542
SDL16-ES542

 

SDL16-BA31
SDL16-BA31

SDL16-CA42
SDL16-CA42

SDL16-CD33 
SDL16-CD33

SDL16-CJ33
SDL16-CJ33

 

Application
1. The push button switch are used in controlling circuit of AC voltage up to 660V/AC 50Hz~60Hz, and DC voltage below 400V. It is used for controlling signal and interlocking purposes. 2.They adopting the non-contacting accessories, self-locked contacting type, safe and reliable, and separate conveniently. 3. Its shape is handsome, specially designed for industrial equipment, have firm fabrics, and have very good quality and very competitive prices. 4. The switches have full and different kinds for different functions, like spring return type, self-locked type, with lamp type, mushroom head type, selector type, with key type and emergency stop type, etc.

Operating & Installation Conditions
1 Operational temperation:-5°c – +40°c the average value less than +35°c in 24 hours 2 Altitude: less than 2000m 3 Atmosphere condition : when the maximum temperature is +40 °c ,the Operational humidity is less than 50%,allow higher humidity in cooler environments. 4 Pollution degree:3 level 5 Installs Category: II 6 No significant Shaking,no impact vibration and no snow or rain 7 No explosive media,the Gas and dust can’t corroding metal and damage the insulation

Categories
Push Button switch

Signal Push Button LAY5-B101

Signal Push Button LAY5-B101

LAY5-B101
LAY5-B101

 

LAY5-B112
LAY5-B112

LAY5-B132H29
LAY5-B132H29

LAY5-B164
LAY5-B164

LAY5-J174H29 
LAY5-J174H29

LAY5-J188H29
LAY5-J188H29

Performance & Merit
1. The signal push button are made of PC materials, which are in good appearance and suitable for assembling. 2. It has the performance of dustproof and corrosion prevention. With great variety of products and flexible packaging. 3. They are widely used in industrial and mining establishments and cabins for controlling and indicating.

Operating & Installation Conditions
1 Operational temperation:-5°c – +40°c the average value less than +35°c in 24 hours 2 Altitude: less than 2000m 3 Atmosphere condition : when the maximum temperature is +40 °c ,the Operational humidity is less than 50%,allow higher humidity in cooler environments. 4 Pollution degree:3 level 5 Installs Category: II 6 No significant Shaking,no impact vibration and no snow or rain 7 No explosive media,the Gas and dust can’t corroding metal and damage the insulation